510(k) · Cleared
ClearedComfort EC710
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Alltech Medical Systems America, Inc. · LNH System, Nuclear Magnetic Resonance Imaging
Cleared on Apr 10, 2017 as substantially equivalent to K141945 (Alltech Medical Systems America, Inc., 2015) after a 146-day review. Its family tree reaches back 3 generations to 2008. 1 of the 4 devices in its family, counting itself, has a Class I recall.
- Decided
- Apr 10, 2017
- Review
- 146 days
- Class
- Class II
- Product code
- LNH
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K082100 (2008). No later device cites it as a predicate yet. 1 of the 4 devices in this family, counting this one, has a Class I recall.
- Root · 3 generations backK082100 Alltech Echostar 1.5 T MR SystemAlltech Medical Systems America, Inc. · 2008
- 2 generations backK113511 Echostar Spica 1.5T MR SystemAlltech Medical Systems America, Inc. · 2012 · Recalled (Class I)
- 1 generation backK141945 Echostar Comfort 1.5T MriAlltech Medical Systems America, Inc. · 2015
- This deviceK163192 Comfort EC710Alltech Medical Systems America, Inc. · 2017
Class I recalls in this family
- K113511 Echostar Spica 1.5T MR System2 generations back · 2012
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K082100 | Alltech Echostar 1.5 T MR System | Alltech Medical Systems America, Inc. | 2008 | — |
| −2 | K113511 | Echostar Spica 1.5T MR System | Alltech Medical Systems America, Inc. | 2012 | Class I |
| −1 | K141945 | Echostar Comfort 1.5T Mri | Alltech Medical Systems America, Inc. | 2015 | — |
| 0 (this device) | K163192 | Comfort EC710 | Alltech Medical Systems America, Inc. | 2017 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LNH device
- #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K141945 | Echostar Comfort 1.5T MriSummary page 4…through the 510(k) premarket notification process, the Echostar Comfort 1.5T MRI System. The Echostar Comfort 1.5T MRI system was cleared by the FDA on February 3, 2015 (K141945). 21 CFR 807.92 (a)(4) Device Description The Comfort EC710, a 1.5T MRI System, represents a modification to the previously clear… | 2015 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K113511Echostar Spica 1.5T MR SystemAlltech Medical Systems America, Inc. · 2012 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 9 years and passes through 1 company; a new generation was cleared every 2.8 years on median.
- 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
How does its category compare?
All LNH devicesLNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.
FDA decisions per year · LNH
26in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LNH
122in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LNH
8in 2025
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · LNH
1,263in 2025
MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 35 | 25 | 114 |
| 2008 | 19 | 53 | 12 | 167 |
| 2009 | 17 | 70 | 7 | 194 |
| 2010 | 12 | 94 | 17 | 165 |
| 2011 | 16 | 81 | 11 | 182 |
| 2012 | 22 | 89 | 5 | 170 |
| 2013 | 19 | 108 | 2 | 107 |
| 2014 | 17 | 108 | 13 | 119 |
| 2015 | 19 | 140 | 12 (2) | 113 |
| 2016 | 20 | 108 | 1 | 135 |
| 2017 | 18 | 98 | 0 | 121 |
| 2018 | 29 | 128 | 71 | 158 |
| 2019 | 26 | 62 | 5 | 158 |
| 2020 | 32 | 121 | 4 | 98 |
| 2021 | 27 | 87 | 41 | 84 |
| 2022 | 30 | 74 | 13 | 138 |
| 2023 | 30 | 124 | 10 (1) | 159 |
| 2024 | 26 | 104 | 4 | 281 |
| 2025 | 26 | 122 | 8 (5) | 1,263 |
| 2026 | 24 | 126 | 43 | — |
What is it indicated for?
The Comfort EC710 is a whole-body magnetic resonance imaging (MRI) system intended for general diagnostic use. Transverse, sagittal, coronal and oblique planes may be imaged. MRI images produced by the Comfort EC710 system reflect the spatial distribution for the density of hydrogen nuclei (protons) spin-lattice relaxation time (T1). spin-spin relaxation time (T2) and flow, When interpreted by a tramed physician. these images yield information that can be useful in the determining of a diagnosis.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K163192 · printed Nov 6, 2026
Cite this page
510(k) Report. “K163192: Comfort EC710.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K163192
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026