510(k) Report

510(k) · Cleared

Cleared

GrindCare System

K163448510(k) TraditionalCleared Sep 1, 2017267-day reviewClass II21 CFR 882.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sunstar Suisse S.A. · HCC Device, Biofeedback

Cleared on Sep 1, 2017 as substantially equivalent to K092675 (Medotech A/S, 2010) after a 267-day review. Its family tree reaches back 3 generations to 1984.

Decided
Sep 1, 2017
Review
267 days
Class
Class II
Product code
HCC
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K842223 (1984). 9 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2004: 2 other ancestors2001: 1 other ancestor2000: 1 other ancestor1999: 1 other ancestor1988: 1 other ancestorK842223 · J4 Myo-Monitor · Myo-Tronics Research, Inc. · 1984K031998 · Model J-5 Mvo-Monitor · Myotronics-Noromed, Inc. · 2003K092675 · Grindcare · Medotech A/S · 20101980199020002010
Other ancestors, by generation 2 generations back: 2 other ancestors3 generations back: 4 other ancestors K092675 · Grindcare · Medotech A/S · 2010K031998 · Model J-5 Mvo-Monitor · Myotronics-Noromed, Inc. · 2003K842223 · J4 Myo-Monitor · Myo-Tronics Research, Inc. · 19840
  1. Root · 3 generations backK842223 J4 Myo-MonitorMyo-Tronics Research, Inc. · 1984
  2. 2 generations backK031998 Model J-5 Mvo-MonitorMyotronics-Noromed, Inc. · 2003
  3. 1 generation backK092675 GrindcareMedotech A/S · 2010
  4. This deviceK163448 GrindCare SystemSunstar Suisse S.A. · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K842223J4 Myo-MonitorMyo-Tronics Research, Inc.1984—
−2K031998Model J-5 Mvo-MonitorMyotronics-Noromed, Inc.2003—
−1K092675GrindcareMedotech A/S2010—
0 (this device)K163448GrindCare SystemSunstar Suisse S.A.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199910
200010
200110
200420
FIG. 1 — Lineage of K163448, 1984–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HCC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HCC device

  1. #1 K233580 A Breathing System (ABS)score 8.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K092675Grindcare
Summary page 4
…t Codes: KZM - Diagnostic Electromyograph NUW - Powered Muscle Stimulator, Dental Predicate Device: GrindCare, K092675 Indication for Use: The GrindCare System is indicated to aid in the evaluation and management of sleep bruxism by reducing the t…
Medotech A/S2010—

Also cleared against K092675: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 4 companies; a new generation was cleared every 7.5 years on median.
  • None of the 9 ancestors has a recall.
  • 1 other device also cites its predicate K092675.

How does its category compare?

All HCC devices

HCC Device, Biofeedback: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · HCC

1in 2024

2007: 12008: 22010: 12011: 12013: 22015: 22017: 12018: 12023: 12024: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HCC

Too few HCC 510(k)s in any year since 2007 to give a median.

Recalls per year · HCC

1in 2015

2012: 12015: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HCC

5in 2024

2007: 22008: 22009: 12011: 42012: 22013: 22014: 22016: 42017: 32018: 12019: 62020: 22022: 32023: 22024: 5
2007high 6 (2019) · low 0 (2010)2025

MAUDE reports naming product code HCC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
20082—02
20090—01
20101—00
20111—04
20120—12
20132—02
20140—02
20152—10
20160—04
20171—03
20181—01
20190—06
20200—02
20210—00
20220—03
20231—02
20241—05
20250—00
20260—0—

What is it indicated for?

The GrindCare System is indicated to aid in the evaluation and management of sleep bruxism by reducing the temporalis muscle EMG activity during sleep.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K163448: GrindCare System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K163448

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026