510(k) Report

510(k) · Cleared

Cleared

nvc

K170074510(k) SpecialCleared Jan 24, 201715-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nvision Biomedical Technologies, LLC · ODP Intervertebral Fusion Device With Bone Graft, Cervical

Cleared on Jan 24, 2017 after a 15-day review. The FDA summary names no predicate by number. 4 later devices descend from it.

Decided
Jan 24, 2017
Review
15 days
Class
Class II
Product code
ODP
Recalls
None
Predicates
0

4 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2019: 1 descendant cleared2024: 1 descendant cleared2023: 1 descendant cleared2025: 1 descendant cleared201620182020202220242026
  1. This deviceK170074 nvcNvision Biomedical Technologies, LLC · 2017
  2. Descendant · cites it directly · 3 of its ownK190380 nvcNvision Biomedical Technologies, Inc. · 2019
  3. Descendant · 2 generations on · 1 of its ownK222015 Integral Titanium Cervical InterbodyNvision Biomedical Technologies, Inc. · 2023
  4. Descendant · 3 generations on · 0 of its ownK243673 Xenco Medical CancelleX Cervical Interbody SystemXenco Medical, LLC · 2025
  5. Descendant · 2 generations on · 0 of its ownK240250 3D Printed PEEK Interbody SystemNvision Biomedical Technologies, Inc. · 2024

Most influential descendants

Showing 4 of 4 · See all
  • K190380nvcNvision Biomedical Technologies, Inc. · 2019 · cites it directly3descendants
  • K222015Integral Titanium Cervical InterbodyNvision Biomedical Technologies, Inc. · 2023 · 2 generations on1descendant
  • K243673Xenco Medical CancelleX Cervical Interbody SystemXenco Medical, LLC · 2025 · 3 generations on0descendants
  • K2402503D Printed PEEK Interbody SystemNvision Biomedical Technologies, Inc. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K170074nvcNvision Biomedical Technologies, LLC2017—
+1K190380nvcNvision Biomedical Technologies, Inc.2019—
+2K222015Integral Titanium Cervical InterbodyNvision Biomedical Technologies, Inc.2023—
+3K243673Xenco Medical CancelleX Cervical Interbody SystemXenco Medical, LLC2025—
+2K2402503D Printed PEEK Interbody SystemNvision Biomedical Technologies, Inc.2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202310
202410
202510
FIG. 1 — Lineage of K170074, 2017–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODP device

  1. #1 K222276 CONDUIT Cages; FIBERGRAFT BG Puttyscore 53.4 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K190380nvcNvision Biomedical Technologies, Inc.20193

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K190380 (Nvision Biomedical Technologies, Inc., 2019) has gone furthest, with 3 descendants of its own.

How does its category compare?

All ODP devices

ODP Intervertebral Fusion Device With Bone Graft, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · ODP

11in 2025

2008: 82009: 122010: 92011: 252012: 172013: 182014: 262015: 242016: 172017: 332018: 252019: 222020: 142021: 182022: 122023: 342024: 102025: 112026 (partial year): 19
2007high 34 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODP

87in 2025

2008: 89 days median2009: 127 days median2010: 151 days median2011: 113 days median2012: 93 days median2013: 187 days median2014: 118 days median2015: 180 days median2016: 112 days median2017: 104 days median2018: 133 days median2019: 92 days median2020: 89 days median2021: 121 days median2022: 92 days median2023: 165 days median2024: 76 days median2025: 87 days median2026 (partial year): 117 days median
2007high 187 (2013) · low 76 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODP

2in 2025

2009: 12011: 12013: 12020: 12025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODP

57in 2025

2008: 22009: 212010: 542011: 382012: 922013: 782014: 432015: 512016: 372017: 392018: 512019: 1412020: 862021: 1612022: 502023: 362024: 552025: 57
2007high 161 (2021) · low 0 (2007)2025

MAUDE reports naming product code ODP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200888902
200912127121
20109151054
201125113138
20121793092
201318187178
201426118043
201524180051
201617112037
201733104039
201825133051
201922920141
20201489186
2021181210161
20221292050
202334165036
20241076055
20251187257
2026191170—

What is it indicated for?

The nvc is intended for spinal fusion procedures at one level, from C2-T1, in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine. DDD is defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies. One device is to be used per intervertebral space. Patients should receive six weeks of non-operative treatment prior to treatment with an intervertebral body fusion device. The nvc devices must be used with supplemental fixation and are designed for use with autograft bone to facilitate fusion. The devices are to be implanted via an anterior approach.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K170074: nvc.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170074

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026