Exactech, Inc. · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Cleared on Feb 23, 2017 as substantially equivalent to K153776 (Exactech, Inc., 2016) after a 28-day review. Its family tree reaches back 9 generations to 1994. 2 later devices descend from it.
- Decided
- Feb 23, 2017
- Review
- 28 days
- Class
- Class II
- Product code
- JWH
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K936079 (1994). 18 ancestors in all. 2 later devices descend from it, 1 citing it directly.
- Root · 9 generations backK936079 Ecactech Porous Coated Finned Tibial Tray CompnentExactech, Inc. · 1994
- 5 generations between
- 3 generations backK121307 Optetrak Logic CR Tibial Insert, Size 0 Optetrak Logic CR Tibial…Exactech, Inc. · 2012
- 2 generations backK123687 Optetrak Logic Porous Femoral ComponentExactech, Inc. · 2013
- 1 generation backK153776 Optetrak One Logic Femoral ComponentsExactech, Inc. · 2016
- This deviceK170240 Truliant Femoral ComponentsExactech, Inc. · 2017
- Descendant · cites it directly · 1 of its ownK171045 Exactech® Truliant™ Line ExtensionsExactech, Inc. · 2017 · Recalled
- Descendant · 2 generations on · 0 of its ownK223252 TRULIANT® E-PX Tibial Inserts; TRULIANT® E-PX PatellasExactech, Inc. · 2023 · Recalled
Show all 9 generations
- Root · 9 generations backK936079 Ecactech Porous Coated Finned Tibial Tray CompnentExactech, Inc. · 1994
- 8 generations backK011976 Optetrak Total Knee System Size 0/1 Delta (Line Extension)Exactech, Inc. · 2001
- 7 generations backK032606 Optetrak Total Knee System Asymmetric Femoral Components Size 6…Exactech, Inc. · 2003
- 6 generations backK033883 Optetrak Total Knee System, HI-Flex Asymmetric Posterior-Stabilized…Exactech, Inc. · 2004 · Recalled
- 5 generations backK093360 Optetrak Logic Total Knee System Trapezoidal Tibial Tray, Sizes…Exactech, Inc. · 2010 · Recalled
- 4 generations backK111400 Optetrak Logic CR Tibial Insert, Optetrak Logic CR Femoral ComponentExactech, Inc. · 2011 · Recalled
- 3 generations backK121307 Optetrak Logic CR Tibial Insert, Size 0 Optetrak Logic CR Tibial…Exactech, Inc. · 2012
- 2 generations backK123687 Optetrak Logic Porous Femoral ComponentExactech, Inc. · 2013
- 1 generation backK153776 Optetrak One Logic Femoral ComponentsExactech, Inc. · 2016
- This deviceK170240 Truliant Femoral ComponentsExactech, Inc. · 2017
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K936079 | Ecactech Porous Coated Finned Tibial Tray Compnent | Exactech, Inc. | 1994 | — |
| −8 | K011976 | Optetrak Total Knee System Size 0/1 Delta (Line Extension) | Exactech, Inc. | 2001 | — |
| −7 | K032606 | Optetrak Total Knee System Asymmetric Femoral Components Size 6… | Exactech, Inc. | 2003 | — |
| −6 | K033883 | Optetrak Total Knee System, HI-Flex Asymmetric Posterior-Stabilized Cemented… | Exactech, Inc. | 2004 | 3 |
| −5 | K093360 | Optetrak Logic Total Knee System Trapezoidal Tibial Tray, Sizes… | Exactech, Inc. | 2010 | 2 |
| −4 | K111400 | Optetrak Logic CR Tibial Insert, Optetrak Logic CR Femoral Component | Exactech, Inc. | 2011 | 1 |
| −3 | K121307 | Optetrak Logic CR Tibial Insert, Size 0 Optetrak Logic CR Tibial Insert, Size… | Exactech, Inc. | 2012 | — |
| −2 | K123687 | Optetrak Logic Porous Femoral Component | Exactech, Inc. | 2013 | — |
| −1 | K153776 | Optetrak One Logic Femoral Components | Exactech, Inc. | 2016 | — |
| 0 (this device) | K170240 | Truliant Femoral Components | Exactech, Inc. | 2017 | — |
| +1 | K171045 | Exactech® Truliant™ Line Extensions | Exactech, Inc. | 2017 | 2 |
| +2 | K223252 | TRULIANT® E-PX Tibial Inserts; TRULIANT® E-PX Patellas | Exactech, Inc. | 2023 | 1 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 3 | 0 |
| 1995 | 3 | 0 |
| 1996 | 1 | 0 |
| 2001 | 1 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
| 2023 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWH device
- #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K153776 | Optetrak One Logic Femoral ComponentsSummary page 4…Device Class II Information on devices to which substantial equivalence is claimed: 510(k) Number Trade or Proprietary Model Name Manufacturer K153776 Exactech One Logic Femoral Components Exactech, Inc Indications for Use: The TRULIANT Femoral Components,… | 2016 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K171045 | Exactech® Truliant™ Line Extensions | 2017 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 23 years and passes through 1 company; a new generation was cleared every 1.5 years on median.
- 9 of the 18 ancestors have a recall of any class.
- Of its descendants, K171045 (Exactech, Inc., 2017) has gone furthest, with 1 descendant of its own.
- 1 other device also cites its predicate K153776.
How does its category compare?
All JWH devicesJWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.
FDA decisions per year · JWH
20in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWH
55in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWH
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JWH
9,306in 2025
MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 74 | 14 | 1,305 |
| 2008 | 17 | 81 | 10 | 1,483 |
| 2009 | 11 | 168 | 109 | 1,870 |
| 2010 | 19 | 85 | 32 | 3,286 |
| 2011 | 25 | 87 | 27 | 5,133 |
| 2012 | 33 | 85 | 85 | 5,203 |
| 2013 | 31 | 128 | 31 | 6,135 |
| 2014 | 33 | 98 | 13 | 6,722 |
| 2015 | 27 | 87 | 11 | 6,881 |
| 2016 | 18 | 88 | 17 | 7,586 |
| 2017 | 25 | 118 | 61 | 12,263 |
| 2018 | 25 | 90 | 14 | 14,071 |
| 2019 | 28 | 133 | 5 | 14,987 |
| 2020 | 22 | 59 | 2 | 12,592 |
| 2021 | 24 | 61 | 8 | 9,408 |
| 2022 | 17 | 56 | 12 | 8,364 |
| 2023 | 20 | 57 | 67 | 8,947 |
| 2024 | 19 | 89 | 7 | 10,828 |
| 2025 | 20 | 55 | 2 | 9,306 |
| 2026 | 12 | 63 | 4 | — |
What is it indicated for?
The TRULIANT Femoral Components, Tibial Inserts, and Tibial Trays are indicated for use in skeletally mature individuals undergoing primary surgery for total knee replacement due to osteoarthritis, osteonecrosis, rheumatoid arthritis and/or post-traumatic degenerative problems. They are also indicated for revision of failed previous reconstructions where sufficient bone stock and soft tissue integrity are present.
The TRULIANT Femoral Components, Tibial Inserts, and Tibial Trays are indicated for cemented use only.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K170240 · printed Nov 6, 2026
Cite this page
510(k) Report. “K170240: Truliant Femoral Components.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170240
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026