510(k) · Cleared
Recalled · Class II · 2019Ion PGM Dx System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Life Technologies Corporation · PFF High Throughput Dna Sequence Analyzer
Cleared on Jun 22, 2017 after a 142-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below). It has been recalled 4 times.
- Decided
- Jun 22, 2017
- Review
- 142 days
- Class
- Class II
- Product code
- PFF
- Recalls
- 4
- Predicates
- 1
The summary cites one number, which could not be confirmed as its predicate (see the table below).
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PFF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| Kept off the family tree | K123989 | Illumina MiSeqDx Platform Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree Summary page 5…21 CFR 862.9 Product Code: PFF - High throughput DNA sequence analyzer Predicate Devices – 21 CFR 807.92(a)(3): Predicates: Illumina MiSeqDx Platform, k123989 (DEN130011) Device Description – 21 CFR 807.92(a)(4): The Ion PGM™ Dx System is used for detection of human variant sequences f… |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 26, 2019 | Class II | Z-0186-2020 | Software design | Torrent SuiteTM Dx analysis software, a component of the Ion PGM Dx Instrument System, incorrectly displays a positive result when a different analytical or de novo variant is detected at the same locus as a specified clinical variant |
| Sep 26, 2019 | Class II | Z-0185-2020 | Software design | Torrent SuiteTM Dx analysis software, a component of the Ion PGM Dx Instrument System, incorrectly displays a positive result when a different analytical or de novo variant is detected at the same locus as a specified clinical variant |
| Sep 26, 2019 | Class II | Z-0188-2020 | Software design | Torrent SuiteTM Dx analysis software, a component of the Ion PGM Dx Instrument System, incorrectly displays a positive result when a different analytical or de novo variant is detected at the same locus as a specified clinical variant |
| Sep 26, 2019 | Class II | Z-0187-2020 | Software design | Torrent SuiteTM Dx analysis software, a component of the Ion PGM Dx Instrument System, incorrectly displays a positive result when a different analytical or de novo variant is detected at the same locus as a specified clinical variant |
No ancestor or descendant has a Class I recall.
How does its category compare?
All PFF devicesPFF High Throughput Dna Sequence Analyzer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.
FDA decisions per year · PFF
1in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · PFF
Too few PFF 510(k)s in any year since 2007 to give a median.
Recalls per year · PFF
6in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PFF
2in 2025
MAUDE reports naming product code PFF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 4 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 0 | — | 1 | 1 |
| 2023 | 0 | — | 0 | 1 |
| 2024 | 0 | — | 6 | 1 |
| 2025 | 0 | — | 0 | 2 |
| 2026 | 0 | — | 1 | — |
What is it indicated for?
The Ion PGM™ Dx Instrument System is composed of a sequencing instrument that measures the hydrogen ions that are generated during the incorporation of nucleotides in the DNA sequencing reaction, and the ancillary instrumentation necessary for sample processing. This instrument system is used in conjunction with the instrument-specific Ion PGM™ Dx Library Kit, Ion OneTouch™ Dx Template Kit, Ion PGM™ Dx Sequencing Kit, and Ion 318™ Dx Chip Kit, and data…
Read the full statement (119 words)
The Ion PGM™ Dx Instrument System is composed of a sequencing instrument that measures the hydrogen ions that are generated during the incorporation of nucleotides in the DNA sequencing reaction, and the ancillary instrumentation necessary for sample processing. This instrument system is used in conjunction with the instrument-specific Ion PGM™ Dx Library Kit, Ion OneTouch™ Dx Template Kit, Ion PGM™ Dx Sequencing Kit, and Ion 318™ Dx Chip Kit, and data analysis software. The Ion PGM™ Dx Instrument System is intended for targeted sequencing of human genomic DNA (gDNA) from peripheral whole-blood samples and DNA and RNA extracted from formalin-fixed, paraffin-embedded (FFPE) samples. The Ion PGM™ Dx Instrument System is not intended for whole genome or de novo sequencing.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K170299 · printed Nov 3, 2026
Cite this page
510(k) Report. “K170299: Ion PGM Dx System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K170299
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026