510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

GLOBAL UNITE Platform Shoulder System

K170748510(k) TraditionalCleared Jan 11, 2018307-day reviewClass II21 CFR 888.3660Recalls 8

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Depuy Ireland UC · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on Jan 11, 2018 as substantially equivalent to K052906 (Zimmer, Inc., 2005) and 3 other predicates after a 307-day review. Its family tree reaches back 8 generations to 1991. 10 later devices descend from it. It has been recalled 8 times.

Decided
Jan 11, 2018
Review
307 days
Class
Class II
Product code
PHX
Recalls
8
Predicates
4

Its longest line of descent runs back 8 generations to K911686 (1991). 41 ancestors in all, the oldest K790987 (1979). 10 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2010: 1 other ancestor2007: 3 other ancestors2006: 2 other ancestors2005: 1 other ancestor2004: 1 other ancestor2001: 3 other ancestors2003: 1 other ancestor1999: 3 other ancestors1998: 2 other ancestors1995: 2 other ancestors2000: 1 other ancestor1996: 4 other ancestors1993: 1 other ancestor1992: 1 other ancestor1989: 1 other ancestor1987: 1 other ancestor1986: 1 other ancestor1980: 2 other ancestors1979: 1 other ancestor2020: 3 descendants cleared2021: 3 descendants cleared2026: 2 descendants cleared2024: 1 descendant cleared2025: 1 descendant clearedK911686 · Global Total Shoulder, Uncement Humeral Hemi-Shoul · Depuy, Inc. · 1991×2: 2 generations cleared close together, K984541 (1999), K992065 (1999) ×3: 3 generations cleared close together, K021478 (2003), K030941 (2004), K041873 (2004) ×2: 2 generations cleared close together, K052906 (2005), K060704 (2006) 19801990200020102020
  1. Root · 8 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 7 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
  3. 6 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
  4. 5 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
  5. 4 generations backK030941 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  6. 3 generations backK041873 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  7. 2 generations backK052906 Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc. · 2005 · Recalled
  8. 1 generation backK060704 Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc. · 2006 · Recalled
  9. This deviceK170748 GLOBAL UNITE Platform Shoulder SystemDepuy Ireland UC · 2018
  10. Descendant · cites it directly · 3 of its ownK191433 AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2020
  11. Descendant · cites it directly · 3 of its ownK192855 DELTA XTEND (TM) Reverse Shoulder SystemDepuy (Ireland) · 2020
  12. Descendant · 2 generations on · 2 of its ownK231657 AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2024
  13. Descendant · 2 generations on · 1 of its ownK241944 AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2025
  14. Descendant · cites it directly · 1 of its ownK202098 GLOBAL UNITE™ Platform Shoulder SystemDepuy Ireland UC · 2020

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2020: 32021: 32024: 12025: 12026: 2
2020high 3 (2020) · low 0 (2022)2026

Most influential descendants

Showing 5 of 10 · See all
  • K191433AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2020 · cites it directly3descendants
  • K192855DELTA XTEND (TM) Reverse Shoulder SystemDepuy (Ireland) · 2020 · cites it directly3descendants
  • K231657AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2024 · 2 generations on2descendants
  • K241944AGILON® XO Shoulder Replacement SystemImplantcast GmbH · 2025 · 2 generations on1descendant
  • K202098GLOBAL UNITE™ Platform Shoulder SystemDepuy Ireland UC · 2020 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K911686Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc.1991—
−7K984541Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc.1999—
−6K992065Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage…DePuy Orthopaedics, Inc.1999—
−5K021478Delta ShoulderDepuy, Inc.2003—
−4K030941Aequalis Reversed Shoulder ProsthesisTornier2004—
−3K041873Aequalis Reversed Shoulder ProsthesisTornier2004—
−2K052906Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc.200512
−1K060704Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc.200610
0 (this device)K170748GLOBAL UNITE Platform Shoulder SystemDepuy Ireland UC2018—
+1K191433AGILON® XO Shoulder Replacement SystemImplantcast GmbH2020—
+1K192855DELTA XTEND (TM) Reverse Shoulder SystemDepuy (Ireland)2020—
+2K231657AGILON® XO Shoulder Replacement SystemImplantcast GmbH2024—
+2K241944AGILON® XO Shoulder Replacement SystemImplantcast GmbH2025—
+1K202098GLOBAL UNITE™ Platform Shoulder SystemDepuy Ireland UC2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198020
198610
198710
198910
199210
199310
199520
199640
199820
199930
200010
200130
200310
200410
200510
200620
200730
201010
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202030
202130
202410
202510
202620
FIG. 1 — Lineage of K170748, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052906Zimmer Trabecular Metal Reverse Shoulder System
Summary page 5
…21 CFR 888.3660; 21 CFR 888.3690 Product Code(s) PHX; KWS; HSD Legally marketed device(s) to Zimmer Trabecular Metal® Reverse Shoulder System, K052906; which equivalence is claimed Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8mm and 1…
Zimmer, Inc.200512
*K060704Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MM
Summary page 5
…l® Reverse Shoulder System, K052906; which equivalence is claimed Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8mm and 10mm, K060704 DePuy GLOBAL UNITE Shoulder System, K101996 DePuy GLOBAL UNITE Sh…
Zimmer, Inc.200610
*K101996Depuy Global Unite Shoulder System
Summary page 5
…Trabecular Metal Reverse Shoulder System, Sizes 8mm and 10mm, K060704 DePuy GLOBAL UNITE Shoulder System, K101996 DePuy GLOBAL UNITE Shoulder System, K133834 Reason for 510(k) submission This 510(k) submissio…
Depuy (Ireland)20108
*K133834Depuy Global Unite Shoulder System
Summary page 5
…10mm, K060704 DePuy GLOBAL UNITE Shoulder System, K101996 DePuy GLOBAL UNITE Shoulder System, K133834 Reason for 510(k) submission This 510(k) submission is to add the GLOBAL UNITE Reverse Fracture…
Depuy (Ireland)20141

Also cleared against K052906: 12 other devices →

What descends from it? (10)

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191433AGILON® XO Shoulder Replacement SystemImplantcast GmbH20203
K192855DELTA XTEND (TM) Reverse Shoulder SystemDepuy (Ireland)20203
K202098GLOBAL UNITE™ Platform Shoulder SystemDepuy Ireland UC20201
K212710GLOBAL UNITE™ Platform Shoulder SystemDepuy Ireland UC20210
K211553Tecomet Global Unite Short Stem InstrumentationSymmetry Medical Manufacturing Inc. Dba Tecomet, Inc.20210

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 7, 2021Class IIZ-0484-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0485-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0486-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0487-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0490-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0483-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0488-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Dec 7, 2021Class IIZ-0489-2022Equipment maintenanceStems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 5 companies; a new generation was cleared every 1.3 years on median.
  • 13 of the 41 ancestors have a recall of any class.
  • Of its descendants, K191433 (Implantcast GmbH, 2020) has gone furthest, with 3 descendants of its own.
  • 12 other devices also cite its predicate K052906.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

The GLOBAL UNITE Platform Shoulder System is intended for cemented or uncemented total or hemi-shoulder arthroplasty in treatment of the following: • A severely painful and/or disabled joint resulting from osteoarthritis, traumatic arthritis or • rheumatoid arthritis • Fracture of the proximal humerus where the articular surface is severely comminuted, separated from its blood supply or where the surgeon’s experience indicates that alternative methods of…

Read the full statement (476 words)

The GLOBAL UNITE Platform Shoulder System is intended for cemented or uncemented total or hemi-shoulder arthroplasty in treatment of the following:

• A severely painful and/or disabled joint resulting from osteoarthritis, traumatic arthritis or

• rheumatoid arthritis

• Fracture of the proximal humerus where the articular surface is severely comminuted, separated from its blood supply or where the surgeon’s experience indicates that alternative methods of treatment are unsatisfactory

• Irreducible 3- and 4-part fractures of the proximal humerus

• Ununited humeral head fractures

• Avascular necrosis of the humeral head

• Other difficult clinical problems where shoulder arthrodesis or resection arthroplasty are not acceptable (e.g. revision of a failed primary component)

Hemi-shoulder arthroplasty is also indicated for:

• Deformity and/or limited motion

The GLOBAL UNITE Reverse Fracture Epiphyseal Component, in conjunction with components from the existing DELTA XTEND™ Reverse Shoulder System and GLOBAL UNITE Platform Shoulder System, is indicated for use in a grossly rotator cuff deficient glenohumeral joint with severe arthropathy or a previously failed joint replacement with a gross rotator cuff deficiency. The patient’s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. It is intended for cemented or uncemented reverse shoulder arthroplasty in treatment of the following:

• Fracture of the proximal humerus where the articular surface is severely comminuted, separated from its blood supply or where the surgeon’s experience indicates that alternative methods of treatment are unsatisfactory

• Irreducible 3- and 4-part fractures of the proximal humerus

• Ununited humeral head fractures

The GLOBAL UNITE Reverse Fracture Epiphyseal Component is only intended for use in the treatment of proximal humeral fractures. Bone preparation instrumentation has not been validated to accommodate its use in a non-fracture press-fit application.

GLOBAL UNITE Humeral Stems, in conjunction with existing DELTA XTEND Epiphyseal Components, are indicated for use in reverse shoulder arthroplasty in treatment of a grossly deficient rotator cuff joint with severe arthropathy or a previously failed joint replacement with a grossly deficient rotator cuff joint. The patient’s joint must be anatomically and structurally suited to receive the reverse implant(s), and a functional deltoid muscle is necessary to use the device.

When used in a total shoulder arthroplasty, the GLOBAL UNITE Implants are to be used with DePuy glenoid components. The glenoid components are for cemented use only. GLOBAL UNITE Humeral Implants are for cemented or uncemented use.

When used in a reverse shoulder arthroplasty, the GLOBAL UNITE and DELTA XTEND Humeral Implants are to be used with the HA-coated DELTA XTEND Metaglene Devices. The metaglene implants are intended for uncemented use only with additional screw fixation. The HA-coated DELTA XTEND Humeral Implants are intended for uncemented use only. GLOBAL UNITE humeral implants are for cemented or uncemented use. The DELTA XTEND epiphyseal components are HA-coated and are intended for uncemented use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K170748: GLOBAL UNITE Platform Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170748

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026