K170889510(k) TraditionalCleared Apr 26, 201733-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wrightmedicaltechnologyinc · HWC Screw, Fixation, Bone

Cleared on Apr 26, 2017 as substantially equivalent to K082320 (Wrightmedicaltechnologyinc, 2008) after a 33-day review. Its family tree reaches back 1 generation to 2008.

Decided
Apr 26, 2017
Review
33 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K082320 (2008). No later device cites it as a predicate yet.

K082320 · Darco Small Screw · Wrightmedicaltechnologyinc · 20082006200820102012201420162018
K082320 · Darco Small Screw · Wrightmedicaltechnologyinc · 20080
  1. Root · 1 generation backK082320 Darco Small ScrewWrightmedicaltechnologyinc · 2008
  2. This deviceK170889 HV Screw SystemWrightmedicaltechnologyinc · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K082320Darco Small ScrewWrightmedicaltechnologyinc2008—
0 (this device)K170889HV Screw SystemWrightmedicaltechnologyinc2017—
FIG. 1 — Lineage of K170889, 2008–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082320Darco Small Screw
Summary page 4
…metallic bone fixation fastener Device Product Code, Device Panel: HWC - Orthopedic 3. Predicate Device: K082320- WrightTM Compression Screw 4. Device Description The HV Screws are cannulated screws offered in 3.0mm diameter, var…
Wrightmedicaltechnologyinc2008—

Also cleared against K082320: 17 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 17 other devices also cite its predicate K082320.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

The HV Screw is indicated for fixation of bone fractures or for bone reconstruction. Examples include:

* Mono or Bi-Cortical osteotomies in the foot or hand

* Distal or Proximal metatarsal or metacarpal osteotomies

* Fusion of the first metatarsophalangeal joint and interphalangeal joint

* Fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.)

* Akin type osteotomy

* Arthrodesis base first metatarsal cuneiform joint to reposition and stabilize metatarsus varus primus

* Talar/navicular arthrodesis

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K170889: HV Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K170889

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026