audifon Tinnitus-Module

K171243510(k) AbbreviatedCleared Oct 19, 2017174-day reviewClass II21 CFR 874.3400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Audiofon USA, Inc. · KLW Masker, Tinnitus

Cleared on Oct 19, 2017 as substantially equivalent to K130514 (Audifon-USA, Inc., 2013) after a 174-day review. Its family tree reaches back 3 generations to 2001.

Decided
Oct 19, 2017
Review
174 days
Class
Class II
Product code
KLW
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K003558 (2001). No later device cites it as a predicate yet.

  1. Root · 3 generations backK003558 Tci Combi (Tinnitus Control Instrument Combination)Siemens Hearing Instruments, Inc. · 2001
  2. 2 generations backK091552 Switch TRTAudifon GmbH & Co. KG · 2009
  3. 1 generation backK130514 Audifon Arriva Cic, IS, IS+, M, S, S+, X TRT, Audifon Vico, Audifon…Audifon-USA, Inc. · 2013
  4. This deviceK171243 audifon Tinnitus-ModuleAudiofon USA, Inc. · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K003558Tci Combi (Tinnitus Control Instrument Combination)Siemens Hearing Instruments, Inc.2001—
−2K091552Switch TRTAudifon GmbH & Co. KG2009—
−1K130514Audifon Arriva Cic, IS, IS+, M, S, S+, X TRT, Audifon Vico, Audifon Prado…Audifon-USA, Inc.2013—
0 (this device)K171243audifon Tinnitus-ModuleAudiofon USA, Inc.2017—
FIG. 1 — Lineage of K171243, 2001–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KLW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KLW device

  1. #1 K260413 Levo Gen 2 Tinnitus Therapy Systemscore 11.8 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130514Audifon Arriva Cic, IS, IS+, M, S, S+, X TRT, Audifon Vico, Audifon Prado, Audifon Elia…
Summary page 4
…D-99625 Kölleda Germany 10. Predicate Device Identification: K130514 audifon vico TRT devices 11. Date of Preparation Ap…
Audifon-USA, Inc.2013—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 4.3 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All KLW devices

KLW Masker, Tinnitus: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · KLW

1in 2024

2007: 22008: 22009: 22010: 12011: 42012: 12013: 42014: 42015: 42016: 32017: 22018: 22020: 22023: 32024: 12026 (partial year): 2
2007high 4 (2011) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KLW

261in 2023

2011: 58 days median2013: 150 days median2014: 164 days median2015: 107 days median2016: 114 days median2023: 261 days median
2007high 261 (2023) · low 58 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KLW

No recall names KLW since 2007.

Adverse event reports per year · KLW

4in 2015

2007: 12009: 12010: 12011: 12012: 12015: 4
2007high 4 (2015) · low 0 (2008)2025

MAUDE reports naming product code KLW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—01
20082—00
20092—01
20101—01
201145801
20121—01
2013415000
2014416400
2015410704
2016311400
20172—00
20182—00
20190—00
20202—00
20210—00
20220—00
2023326100
20241—00
20250—00
20262—0—

What is it indicated for?

audifon Tinnitus-Module is a tool intended to generate sound as part of a Tinnitus Retraining Therapy (TRT) protocol designed to provide temporary relief for people experiencing tinnitus symptoms. The module can be embedded in a hearing aid.

audifon Tinnitus-Module is intended for adults over 18 years of age.

audifon Tinnitus-Module is targeted for licensed hearing care professionals who are familiar with the evaluation and treatment of tinnitus and hearing losses. The fitting of audifon Tinnitus-Module must be done by a hearing care professional participating in a tinnitus management program.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K171243: audifon Tinnitus-Module.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K171243

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026