510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

Williams Cystoscopic Injection Needle

K171602510(k) TraditionalCleared Jul 28, 201757-day reviewClass II21 CFR 876.1500Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook Incorporated · FBK Endoscopic Injection Needle, Gastroenterology-Urology

Cleared on Jul 28, 2017 as substantially equivalent to K022484 (Cook Urological, Inc., 2002) after a 57-day review. Its family tree reaches back 5 generations to 1982. 1 later device descends from it. It has been recalled once.

Decided
Jul 28, 2017
Review
57 days
Class
Class II
Product code
FBK
Recalls
1
Predicates
1

Its longest line of descent runs back 5 generations to K820973 (1982). 9 ancestors in all, the oldest K812057 (1981). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1998: 1 other ancestor1981: 1 other ancestor1993: 1 other ancestor1984: 1 other ancestor2019: 1 descendant clearedK820973 · Endoscopic Injection Needle · Mill-Rose Laboratory · 1982K960519 · Martech Endoscopic Injection Needle · Martech Medical Products, Inc. · 1996K982890 · Advanced Uroscience Injection Needle · Advanced Uroscience, Inc. · 1998K990996 · Genyx Medical Injection Needle · Genyx Medical, Inc. · 1999K022484 · Cook Injection Needle · Cook Urological, Inc. · 200219801990200020102020
  1. Root · 5 generations backK820973 Endoscopic Injection NeedleMill-Rose Laboratory · 1982
  2. 4 generations backK960519 Martech Endoscopic Injection NeedleMartech Medical Products, Inc. · 1996
  3. 3 generations backK982890 Advanced Uroscience Injection NeedleAdvanced Uroscience, Inc. · 1998
  4. 2 generations backK990996 Genyx Medical Injection NeedleGenyx Medical, Inc. · 1999
  5. 1 generation backK022484 Cook Injection NeedleCook Urological, Inc. · 2002
  6. This deviceK171602 Williams Cystoscopic Injection NeedleCook Incorporated · 2017
  7. Descendant · cites it directly · 0 of its ownK182876 Uro-N CystoscopeUroviu Corporation · 2019

Most influential descendants

Showing 1 of 1 · See all
  • K182876Uro-N CystoscopeUroviu Corporation · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K820973Endoscopic Injection NeedleMill-Rose Laboratory1982—
−4K960519Martech Endoscopic Injection NeedleMartech Medical Products, Inc.1996—
−3K982890Advanced Uroscience Injection NeedleAdvanced Uroscience, Inc.1998—
−2K990996Genyx Medical Injection NeedleGenyx Medical, Inc.1999—
−1K022484Cook Injection NeedleCook Urological, Inc.2002—
0 (this device)K171602Williams Cystoscopic Injection NeedleCook Incorporated2017—
+1K182876Uro-N CystoscopeUroviu Corporation2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198410
199310
199810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K171602, 1982–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FBK device

  1. #1 K253598 InjecSURE Injection Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022484Cook Injection Needle
Summary page 4
…§876.1500, Product Code FBK Device Class/Classification Panel: Class II, Gastroenterology/Urology Predicate Device: Cook Injection Needles (Cook Urological Inc., K022484) is the predicate device for the Williams Cystoscopic Injection Needle. Device Description: The Williams Cystoscopic Injection…
Cook Urological, Inc.2002—

Also cleared against K022484: 5 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K182876Uro-N CystoscopeUroviu Corporation20190

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 16, 2026Class IIZ-0163-2027Under Investigation by firmThe female Luer lock adapter component in the affected device lots may not have been correctly seated due to misalignment and inadequate torquing during manufacturing. Potential events that may occur as a result of this issue include…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 6 companies; a new generation was cleared every 3.4 years on median.
  • None of the 9 ancestors has a recall.
  • Of its descendants, K182876 (Uroviu Corporation, 2019) has gone furthest, with 0 descendants of its own.
  • 5 other devices also cite its predicate K022484.

How does its category compare?

All FBK devices

FBK Endoscopic Injection Needle, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · FBK

3in 2025

2008: 12009: 42011: 12012: 22014: 22015: 32016: 22017: 32018: 22019: 12020: 22021: 12022: 62023: 32024: 42025: 32026 (partial year): 2
2007high 6 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FBK

155in 2025

2009: 101 days median2015: 103 days median2017: 51 days median2022: 213 days median2023: 177 days median2024: 192 days median2025: 155 days median
2007high 213 (2022) · low 51 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FBK

9in 2024

2016: 12021: 202022: 82023: 12024: 92026 (partial year): 1
2007high 20 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FBK

81in 2025

2007: 32008: 222009: 122010: 122011: 22012: 22013: 32014: 92015: 42016: 182017: 272018: 92019: 62020: 252021: 342022: 802023: 602024: 942025: 81
2007high 94 (2024) · low 2 (2011)2025

MAUDE reports naming product code FBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20081—022
20094101012
20100—012
20111—02
20122—02
20130—03
20142—09
2015310304
20162—118
2017351027
20182—09
20191—06
20202—025
20211—2034
20226213880
20233177160
20244192994
20253155081
20262—1—

What is it indicated for?

The Williams Cystoscopic Injection Needle is used for cystoscopic injection into the urethra, bladder neck, and bladder wall.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K171602: Williams Cystoscopic Injection Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K171602

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026