510(k) Report

510(k) · Cleared

Cleared

ACISTCVi® Contrast Delivery System

K171646510(k) TraditionalCleared Feb 16, 2018256-day reviewClass II21 CFR 870.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Acist Medical Systems, Inc. · DXT Injector And Syringe, Angiographic

Cleared on Feb 16, 2018 as substantially equivalent to K991103 (Acist Medical Systems, 2000) and 1 other predicate after a 256-day review. Its family tree reaches back 4 generations to 1982. 4 later devices descend from it.

Decided
Feb 16, 2018
Review
256 days
Class
Class II
Product code
DXT
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K822536 (1982). 7 ancestors in all. 4 later devices descend from it, 2 citing it directly.

Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant K991103 · Modification to Acist CL 100H · Acist Medical Systems · 2000 · recalledK984058 · Acist Injector System, Model CL100 H · Acist Medical Systems · 1999K963982 · Acist Angiographic Injector · Invasatec · 1997K822536 · MARK V · Medrad, Inc. · 19820
  1. Root · 4 generations backK822536 MARK VMedrad, Inc. · 1982
  2. 3 generations backK963982 Acist Angiographic InjectorInvasatec · 1997
  3. 2 generations backK984058 Acist Injector System, Model CL100 HAcist Medical Systems · 1999
  4. 1 generation backK991103 Modification to Acist CL 100HAcist Medical Systems · 2000 · Recalled
  5. This deviceK171646 ACISTCVi® Contrast Delivery SystemAcist Medical Systems, Inc. · 2018
  6. Descendant · cites it directly · 2 of its ownK191060 ACIST CVI1 Contrast Delivery System, A1000 Syringe Kit, A1000V…Acist Medical Systems, Inc. · 2019
  7. Descendant · 2 generations on · 1 of its ownK203004 ACIST CVi1 Contrast Delivery System, ACIST CVi Contrast Delivery…Acist Medical Systems, Inc. · 2020
  8. Descendant · cites it directly · 0 of its ownK252653 ACIST Pro Diagnostic System (019304); Processing Unit Bed Mount…Acist Medical Systems, Inc. · 2026
  9. Descendant · 3 generations on · 0 of its ownK252638 VeraPro S100 Multi-Use Syringe (018808); VeraPro S100 LV1 Low…Acist Medical Systems, Inc. · 2026

Most influential descendants

Showing 4 of 4 · See all
  • K191060ACIST CVI1 Contrast Delivery System, A1000 Syringe Kit, A1000V Syringe Kit, BT2000…Acist Medical Systems, Inc. · 2019 · cites it directly2descendants
  • K203004ACIST CVi1 Contrast Delivery System, ACIST CVi Contrast Delivery SystemAcist Medical Systems, Inc. · 2020 · 2 generations on1descendant
  • K252653ACIST Pro Diagnostic System (019304); Processing Unit Bed Mount; AngioTouch Module…Acist Medical Systems, Inc. · 2026 · cites it directly0descendants
  • K252638VeraPro S100 Multi-Use Syringe (018808); VeraPro S100 LV1 Low Viscosity Single-Use…Acist Medical Systems, Inc. · 2026 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K822536MARK VMedrad, Inc.1982—
−3K963982Acist Angiographic InjectorInvasatec1997—
−2K984058Acist Injector System, Model CL100 HAcist Medical Systems1999—
−1K991103Modification to Acist CL 100HAcist Medical Systems20003
0 (this device)K171646ACISTCVi® Contrast Delivery SystemAcist Medical Systems, Inc.2018—
+1K191060ACIST CVI1 Contrast Delivery System, A1000 Syringe Kit, A1000V Syringe Kit…Acist Medical Systems, Inc.2019—
+2K203004ACIST CVi1 Contrast Delivery System, ACIST CVi Contrast Delivery SystemAcist Medical Systems, Inc.2020—
+1K252653ACIST Pro Diagnostic System (019304); Processing Unit Bed Mount; AngioTouch…Acist Medical Systems, Inc.2026—
+3K252638VeraPro S100 Multi-Use Syringe (018808); VeraPro S100 LV1 Low Viscosity…Acist Medical Systems, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199610
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202010
202620
FIG. 1 — Lineage of K171646, 1982–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXT device

  1. #1 K253048 High Pressure Syringe; Pressure Connecting…score 13.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K991103Modification to Acist CL 100H
Summary page 4
…Name Contrast Delivery System Product Code DXT Classification Class II, 21 CFR Part 870.1650, Angiographic injector and syringe Primary K991103 ACIST Angiographic Contrast Management Injector Predicate System, Model CMS2000 Device Secondary…
Acist Medical Systems20003
*K984231Angiographic Contrast Management System, Model Part a and Part B
Summary page 4
…Primary K991103 ACIST Angiographic Contrast Management Injector Predicate System, Model CMS2000 Device Secondary K984231 ACIST Angiographic Contrast Management System Predicate Device Reference K010390 ACIST Angiographic Contr…
Invasatec20004
†K010390Acist Angiographic Injection System, Model R2000-CMSAcist Medical Systems, Inc.20011
†K040298Acist Antiographic Injection System Contrast Management Disposable KitsAcist Medical Systems, Inc.20043
†K151048CT Expres 3D Contrast Media Delivery System, Bottle Spike Type B, Day Set III HP…Bracco Injeneering2016—

Also cleared against K991103: 1 other device →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191060ACIST CVI1 Contrast Delivery System, A1000 Syringe Kit, A1000V Syringe Kit, BT2000…Acist Medical Systems, Inc.20192
K252653ACIST Pro Diagnostic System (019304); Processing Unit Bed Mount; AngioTouch Module…Acist Medical Systems, Inc.20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 36 years and passes through 4 companies; a new generation was cleared every 15.2 years on median.
  • 2 of the 7 ancestors have a recall of any class.
  • Of its descendants, K191060 (Acist Medical Systems, Inc., 2019) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K991103.

How does its category compare?

All DXT devices

DXT Injector And Syringe, Angiographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · DXT

1in 2025

2007: 32008: 22009: 62010: 12011: 42013: 22014: 62015: 72016: 82017: 72018: 92019: 42020: 32021: 12023: 12024: 42025: 12026 (partial year): 7
2007high 9 (2018) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXT

138in 2024

2007: 182 days median2009: 137 days median2011: 69 days median2014: 144 days median2015: 153 days median2016: 172 days median2017: 183 days median2018: 93 days median2019: 96 days median2020: 154 days median2024: 138 days median2026 (partial year): 264 days median
2007high 264 (2026) · low 69 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXT

10in 2024

2007: 42008: 32009: 72010: 32011: 32012: 72015: 12018: 22020: 12021: 12023: 22024: 102026 (partial year): 6
2007high 10 (2024) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXT

97in 2025

2007: 1072008: 1682009: 1882010: 1242011: 1332012: 1352013: 1412014: 972015: 1352016: 1522017: 1282018: 1292019: 1212020: 932021: 1322022: 1112023: 1172024: 1182025: 97
2007high 188 (2009) · low 93 (2020)2025

MAUDE reports naming product code DXT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731824107
20082—3168
200961377188
20101—3124
20114693133
20120—7135
20132—0141
20146144097
201571531135
201681720152
201771830128
20189932129
20194960121
20203154193
20211—1132
20220—0111
20231—2117
2024413810118
20251—097
202672646—

What is it indicated for?

The ACIST|CVi® Contrast Delivery System is indicated for controlled administration of radiopaque contrast media and saline to human subjects while undergoing angiographic procedures. The ACIST|CVi® Contrast Delivery System is specifically indicated for use in angiographic procedures for the delivery of ISOVUE (Iopamidol Injection) contrast media as supplied in an Imaging Bulk Package (IBP), for a maximum of ten (10) hours. The Syringe Kit must be…

Read the full statement (128 words)

The ACIST|CVi® Contrast Delivery System is indicated for controlled administration of radiopaque contrast media and saline to human subjects while undergoing angiographic procedures.

The ACIST|CVi® Contrast Delivery System is specifically indicated for use in angiographic procedures for the delivery of ISOVUE (Iopamidol Injection) contrast media as supplied in an Imaging Bulk Package (IBP), for a maximum of ten (10) hours. The Syringe Kit must be discarded after six (6) patient procedures. The Manifold Kit and AngioTouch Hand Controller Kit must be discarded after each patient procedure.

The ACIST|CVi® Contrast Delivery System is to be used only by and under quasi-continuous supervision of trained health care professionals in an appropriate licensed health care facility, in a room designated for radiological procedures that involve intravascular administration of a contrast agent.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K171646: ACISTCVi® Contrast Delivery System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K171646

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026