510(k) Report

510(k) · Cleared

Cleared

Follicle Aspiration Set, Reduced Single Lumen

K172050510(k) TraditionalCleared Nov 21, 2017138-day reviewClass II21 CFR 884.6100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vitrolife Sweden AB · MQE Needle, Assisted Reproduction

Cleared on Nov 21, 2017 as substantially equivalent to K082727 (Vitrolife Sweden AB, 2009) after a 138-day review. Its family tree reaches back 2 generations to 1999.

Decided
Nov 21, 2017
Review
138 days
Class
Class II
Product code
MQE
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K991273 (1999). No later device cites it as a predicate yet.

  1. Root · 2 generations backK991273 Swemed Follicle Aspiration Set, Double Lumen, Single Lumen, and Luer…Swemed Lab International AB · 1999
  2. 1 generation backK082727 Follicle Aspiration Set, Reduced Single LumenVitrolife Sweden AB · 2009
  3. This deviceK172050 Follicle Aspiration Set, Reduced Single LumenVitrolife Sweden AB · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K991273Swemed Follicle Aspiration Set, Double Lumen, Single Lumen, and Luer NeedleSwemed Lab International AB1999—
−1K082727Follicle Aspiration Set, Reduced Single LumenVitrolife Sweden AB2009—
0 (this device)K172050Follicle Aspiration Set, Reduced Single LumenVitrolife Sweden AB2017—
FIG. 1 — Lineage of K172050, 1999–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQE device

  1. #1 K240523 VitaVitro® Single Lumen Oocyte Retrieval…score 8.3 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082727Follicle Aspiration Set, Reduced Single Lumen
Summary page 4
…II Product Code MQE (Needle, Assisted Reproduction) Predicate Follicle Aspiration Set, Reduced Single Lumen (K082727). This predicate device has not been subjected to a design-…
Vitrolife Sweden AB2009—

Also cleared against K082727: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 9.5 years on median.
  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K082727.

How does its category compare?

All MQE devices

MQE Needle, Assisted Reproduction: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · MQE

2in 2024

2009: 12012: 12014: 12017: 42018: 12019: 32024: 22026 (partial year): 1
2007high 4 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQE

197in 2019

2017: 234 days median2019: 197 days median
2007high 234 (2017) · low 197 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQE

1in 2008

2008: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQE

37in 2025

2010: 22011: 12013: 42014: 32016: 182017: 32018: 52019: 52020: 12022: 22023: 372024: 202025: 37
2007high 37 (2023) · low 0 (2007)2025

MAUDE reports naming product code MQE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—10
20091—00
20100—02
20110—01
20121—00
20130—04
20141—03
20150—00
20160—018
2017423403
20181—05
2019319705
20200—01
20210—00
20220—02
20230—037
20242—020
20250—037
20261—0—

What is it indicated for?

Intended for flushing and/or aspiration of oocytes from ovarian follicles.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172050: Follicle Aspiration Set, Reduced Single Lumen.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172050

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026