510(k) · Cleared
ClearedPRECICE UNYTE System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nuvasive Specialized Orthopedics, Inc. · HSB Rod, Fixation, Intramedullary And Accessories
Cleared on Aug 24, 2017 after a 48-day review. The FDA summary names no predicate by number. 17 later devices descend from it.
- Decided
- Aug 24, 2017
- Review
- 48 days
- Class
- Class II
- Product code
- HSB
- Recalls
- None
- Predicates
- 0
17 later devices descend from it, 1 citing it directly.
- This deviceK172061 PRECICE UNYTE SystemNuvasive Specialized Orthopedics, Inc. · 2017
- Descendant · cites it directly · 16 of its ownK172628 PRECICE SystemNuvasive Specialized Orthopedics, Inc. · 2017
- Descendant · 2 generations on · 13 of its ownK173129 PRECICE SystemNuvasive Specialized Orthopedics, Inc. · 2017
- Descendant · 3 generations on · 12 of its ownK180503 PRECICE STRYDE SystemNuvasive Specialized Orthopedics, Inc. · 2018 · Recalled
- Descendant · 3 generations on · 6 of its ownK182170 PRECICE® BONE TRANSPORT™ SystemNuvasive Specialized Orthopedics, Inc. · 2019 · Recalled
- Descendant · 4 generations on · 4 of its ownK193016 PRECICE Bone Transport SystemNuvasive Specialized Orthopedics, Inc. · 2020 · Recalled
Showing 5 of 17 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 17 · See all- K172628PRECICE SystemNuvasive Specialized Orthopedics, Inc. · 2017 · cites it directly16descendants
- K173129PRECICE SystemNuvasive Specialized Orthopedics, Inc. · 2017 · 2 generations on13descendants
- K180503PRECICE STRYDE SystemNuvasive Specialized Orthopedics, Inc. · 2018 · 3 generations on12descendants
- K182170PRECICE® BONE TRANSPORT™ SystemNuvasive Specialized Orthopedics, Inc. · 2019 · 3 generations on6descendants
- K193016PRECICE Bone Transport SystemNuvasive Specialized Orthopedics, Inc. · 2020 · 4 generations on4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K172061 | PRECICE UNYTE System | Nuvasive Specialized Orthopedics, Inc. | 2017 | — |
| +1 | K172628 | PRECICE System | Nuvasive Specialized Orthopedics, Inc. | 2017 | — |
| +2 | K173129 | PRECICE System | Nuvasive Specialized Orthopedics, Inc. | 2017 | — |
| +3 | K180503 | PRECICE STRYDE System | Nuvasive Specialized Orthopedics, Inc. | 2018 | 1 |
| +3 | K182170 | PRECICE® BONE TRANSPORT™ System | Nuvasive Specialized Orthopedics, Inc. | 2019 | 1 |
| +4 | K193016 | PRECICE Bone Transport System | Nuvasive Specialized Orthopedics, Inc. | 2020 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 2 | 0 |
| 2018 | 1 | 0 |
| 2019 | 2 | 0 |
| 2020 | 5 | 0 |
| 2023 | 3 | 0 |
| 2024 | 1 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HSB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HSB device
- #1 K200869 Gamma3 Systemscore 19.8 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (17)
See all 171 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K172628 | PRECICE System | 2017 | 16 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K172628 (Nuvasive Specialized Orthopedics, Inc., 2017) has gone furthest, with 16 descendants of its own.
How does its category compare?
All HSB devicesHSB Rod, Fixation, Intramedullary And Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.
FDA decisions per year · HSB
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HSB
106in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HSB
18in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HSB
2,911in 2025
MAUDE reports naming product code HSB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 8 | 68 | 0 | 162 |
| 2008 | 11 | 57 | 9 | 184 |
| 2009 | 18 | 86 | 81 | 334 |
| 2010 | 14 | 117 | 18 | 454 |
| 2011 | 16 | 78 | 2 | 662 |
| 2012 | 17 | 112 | 7 | 1,079 |
| 2013 | 18 | 105 | 14 | 1,773 |
| 2014 | 19 | 147 | 3 | 1,474 |
| 2015 | 22 | 111 | 3 | 1,671 |
| 2016 | 8 | 124 | 6 | 1,920 |
| 2017 | 23 | 119 | 66 | 1,447 |
| 2018 | 17 | 134 | 56 | 3,526 |
| 2019 | 13 | 132 | 6 | 2,517 |
| 2020 | 17 | 112 | 6 | 3,299 |
| 2021 | 10 | 94 | 2 | 4,111 |
| 2022 | 12 | 172 | 1 | 2,733 |
| 2023 | 11 | 162 | 1 | 2,219 |
| 2024 | 13 | 195 | 1 | 2,869 |
| 2025 | 15 | 106 | 18 | 2,911 |
| 2026 | 18 | 151 | 1 | — |
https://510kreport.com/device/K172061 · printed Nov 6, 2026
Cite this page
510(k) Report. “K172061: PRECICE UNYTE System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172061
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026