Piezotome Cube

K172137510(k) TraditionalCleared May 3, 2018290-day reviewClass II21 CFR 872.4120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Satelec - Acteon Group · DZI Drill, Bone, Powered

Cleared on May 3, 2018 as substantially equivalent to K112188 (Satelec - Acteon, Inc., 2012) after a 290-day review. Its family tree reaches back 5 generations to 2002.

Decided
May 3, 2018
Review
290 days
Class
Class II
Product code
DZI
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K020833 (2002). No later device cites it as a predicate yet.

  1. Root · 5 generations backK020833 Boyd Delivery UnitBoyd Industries, Inc. · 2002
  2. 4 generations backK040529 Cocoon HygienistSatelec · 2004
  3. 3 generations backK072030 Implant CenterSatelec - Acteon Group · 2007
  4. 2 generations backK091252 Implant Center 2Satelec · 2009
  5. 1 generation backK112188 Piezotome SoloSatelec - Acteon, Inc. · 2012
  6. This deviceK172137 Piezotome CubeSatelec - Acteon Group · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K020833Boyd Delivery UnitBoyd Industries, Inc.2002—
−4K040529Cocoon HygienistSatelec2004—
−3K072030Implant CenterSatelec - Acteon Group2007—
−2K091252Implant Center 2Satelec2009—
−1K112188Piezotome SoloSatelec - Acteon, Inc.2012—
0 (this device)K172137Piezotome CubeSatelec - Acteon Group2018—
FIG. 1 — Lineage of K172137, 2002–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DZI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DZI device

  1. #1 K253776 Implantmed Plus II & Piezomed Plus II Modulescore 12.1 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112188Piezotome Solo
Summary page 5
…Manufacturer Product Code 510(k) number Date Cleared PIEZOTOME SOLO SATELEC DZI K112188 Feb 03, 2012 PIEZOTOME SOLO LED IV –DEVICE DESCRIPTION SATELEC CUBE is an piezoelectric device that uses micro-vib…
Satelec - Acteon, Inc.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 2.5 years on median.
  • None of the 5 ancestors has a recall.

How does its category compare?

All DZI devices

DZI Drill, Bone, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · DZI

1in 2025

2007: 22008: 42009: 52011: 22012: 42014: 12015: 32016: 12018: 32020: 32023: 12024: 22025: 12026 (partial year): 2
2007high 5 (2009) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DZI

300in 2020

2008: 171 days median2009: 220 days median2012: 191 days median2015: 123 days median2018: 290 days median2020: 300 days median
2007high 300 (2020) · low 123 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DZI

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DZI

39in 2025

2007: 532008: 452009: 222010: 152011: 422012: 252013: 572014: 502015: 392016: 432017: 382018: 732019: 502020: 552021: 842022: 632023: 632024: 582025: 39
2007high 84 (2021) · low 15 (2010)2025

MAUDE reports naming product code DZI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—053
20084171045
20095220122
20100—015
20112—042
20124191025
20130—057
20141—050
20153123039
20161—043
20170—038
20183290073
20190—050
20203300055
20210—084
20220—063
20231—063
20242—058
20251—039
20262—0—

What is it indicated for?

The PIEZOTOME CUBE is an ultrasonic surgical system that supply utilities to and serve as a base for dental tips. The PIEZOTOME CUBE consist of a control unit and handpiece intended for use in intraoral surgery procedures, including osteotomy, osteoplasty, periodontics and implantology.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172137: Piezotome Cube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172137

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026