Orthofix Srl · OBT Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
Cleared on Jan 9, 2018 as substantially equivalent to K093442 (Orthofix, Inc., 2010) after a 174-day review. Its family tree reaches back 2 generations to 2003. 1 later device descends from it.
- Decided
- Jan 9, 2018
- Review
- 174 days
- Class
- Class II
- Product code
- OBT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K031493 (2003). 1 later device descends from it, 1 citing it directly.
- Root · 2 generations backK031493 Growth Guidance PlateUniversity of Utah/School of Medicine · 2003
- 1 generation backK093442 Guided Growth SystemOrthofix, Inc. · 2010
- This deviceK172183 Guided Growth Plate System PlusOrthofix Srl · 2018
- Descendant · cites it directly · 0 of its ownK180624 Guided Growth Plate System PlusOrthofix Srl · 2018
Most influential descendants
Showing 1 of 1 · See all- K180624Guided Growth Plate System PlusOrthofix Srl · 2018 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K031493 | Growth Guidance Plate | University of Utah/School of Medicine | 2003 | — |
| −1 | K093442 | Guided Growth System | Orthofix, Inc. | 2010 | — |
| 0 (this device) | K172183 | Guided Growth Plate System Plus | Orthofix Srl | 2018 | — |
| +1 | K180624 | Guided Growth Plate System Plus | Orthofix Srl | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OBT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OBT device
- #1 K220190 The GIRO Growth Modulation Systemscore 5.1 · 4 generations · no Class I recall
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K093442 | Guided Growth SystemSummary page 4…ic, epiphysiodesis Class Class Il Regulation Number | 21 CFR 888.3030 Product Code OBT Name of Predicate Device 510(k) # Manufacturer Guided Growth System Quad-Plate K093442 Orthofix Srl Description The Guided Growth Plate System Plus is designed for the gradual correction of pediatric congenital as… | 2010 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K180624 | Guided Growth Plate System Plus | 2018 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 7.6 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K180624 (Orthofix Srl, 2018) has gone furthest, with 0 descendants of its own.
- 2 other devices also cite its predicate K093442.
How does its category compare?
All OBT devicesOBT Plate, Bone, Growth Control, Pediatric, Epiphysiodesis: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · OBT
1in 2022
2026 to Oct 25, outlined.
Median 510(k) review, days · OBT
Too few OBT 510(k)s in any year since 2007 to give a median.
Recalls per year · OBT
No recall names OBT since 2007.
Adverse event reports per year · OBT
2in 2025
MAUDE reports naming product code OBT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 1 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 2 | — | 0 | 0 |
| 2019 | 1 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 3 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 1 | — | 0 | 1 |
| 2023 | 0 | — | 0 | 1 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 2 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Guided Growth Plate System Plus is intended for redirecting the growth of long bones.
It is indicated for gradually correcting angular growth deformities in growing children. Specific conditions/diseases for which the device will be indicated include: valgus, varus or flexion, extension deformities of the knee (femur and/or tibia); valgus, varus, or plantar flexion deformities of the ankle; valgus or varus deformities of the elbow (humerus), and radial or ulnar deviation, flexion or extension deformities of the wrist (radius).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K172183 · printed Nov 6, 2026
Cite this page
510(k) Report. “K172183: Guided Growth Plate System Plus.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172183
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026