K172311510(k) TraditionalCleared Dec 15, 2017136-day reviewClass II21 CFR 870.2920

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biotricity, Inc. · DXH Transmitters And Receivers, Electrocardiograph, Telephone

Cleared on Dec 15, 2017 as substantially equivalent to K141813 (RhythMedix, LLC, 2014) after a 136-day review. Its family tree reaches back 7 generations to 1997. 1 later device descends from it.

Decided
Dec 15, 2017
Review
136 days
Class
Class II
Product code
DXH
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K963725 (1997). 17 ancestors in all, the oldest K960499 (1996). 1 later device descends from it, 1 citing it directly.

  1. Root · 7 generations backK963725 Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device…Card Guard, Ltd. · 1997
  2. 6 generations backK012223 CG-2211 Selfcheck Ecg TransmitterCard Guard Scientific Survival, Ltd. · 2001
  3. 5 generations backK042254 PMP4 Selfcheck EcgCard Guard Scientific Survival, Ltd. · 2005
  4. 4 generations backK060911 CG-6108 Arrhythmia Ecg Event RecorderCard Guard Scientific Survival, Ltd. · 2006
  5. 3 generations backK083535 Heartrak Smart EcatUniversal Medical, Inc. · 2008
  6. 2 generations backK131699 Emotion Ecg MobileMega Electronics, Ltd. · 2013
  7. 1 generation backK141813 Rhythmstar SystemRhythMedix, LLC · 2014
  8. This deviceK172311 BioFlux DeviceBiotricity, Inc. · 2017
  9. Descendant · cites it directly · 0 of its ownK233864 ASSURE Wearable ECGKestra Medical Technologies, Inc. · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K233864ASSURE Wearable ECGKestra Medical Technologies, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K963725Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified)Card Guard, Ltd.1997—
−6K012223CG-2211 Selfcheck Ecg TransmitterCard Guard Scientific Survival, Ltd.2001—
−5K042254PMP4 Selfcheck EcgCard Guard Scientific Survival, Ltd.2005—
−4K060911CG-6108 Arrhythmia Ecg Event RecorderCard Guard Scientific Survival, Ltd.2006—
−3K083535Heartrak Smart EcatUniversal Medical, Inc.2008—
−2K131699Emotion Ecg MobileMega Electronics, Ltd.2013—
−1K141813Rhythmstar SystemRhythMedix, LLC2014—
0 (this device)K172311BioFlux DeviceBiotricity, Inc.2017—
+1K233864ASSURE Wearable ECGKestra Medical Technologies, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199710
199910
200010
200110
200310
200410
200510
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K172311, 1997–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXH device

  1. #1 K243438 MEMO Patch M (MPT-E08R-UNC01)score 12.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141813Rhythmstar System
Summary page 4
…ially equivalent in intended use and similar technological characteristics the following device, Rhythmedix, LLC. RhythmStar System which was cleared under K141813. K172311 Pg. 1 of 6 6 IV.…
RhythMedix, LLC2014—

Also cleared against K141813: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233864ASSURE Wearable ECGKestra Medical Technologies, Inc.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 6 companies; a new generation was cleared every 3.3 years on median.
  • None of the 17 ancestors has a recall.
  • Of its descendants, K233864 (Kestra Medical Technologies, Inc., 2024) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K141813.

How does its category compare?

All DXH devices

DXH Transmitters And Receivers, Electrocardiograph, Telephone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · DXH

4in 2025

2007: 32008: 72009: 22010: 22012: 12013: 32014: 62015: 42016: 12017: 52018: 42019: 62020: 52021: 32022: 42023: 12025: 42026 (partial year): 1
2007high 7 (2008) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXH

322in 2025

2007: 202 days median2008: 41 days median2013: 206 days median2014: 186 days median2015: 142 days median2017: 150 days median2018: 294 days median2019: 177 days median2020: 141 days median2021: 107 days median2022: 150 days median2025: 322 days median
2007high 322 (2025) · low 41 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXH

1in 2015

2008: 42011: 32015: 12026 (partial year): 1
2007high 4 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXH

27in 2025

2009: 12010: 42011: 12012: 12013: 12014: 12016: 52017: 42020: 52021: 22022: 62023: 42024: 22025: 27
2007high 27 (2025) · low 0 (2007)2025

MAUDE reports naming product code DXH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007320200
200874140
20092—01
20102—04
20110—31
20121—01
2013320601
2014618601
2015414210
20161—05
2017515004
2018429400
2019617700
2020514105
2021310702
2022415006
20231—04
20240—02
20254322027
20261—1—

What is it indicated for?

The bioflux Device is intended for use by patients who either have or are at risk of having cardiac disease and those that demonstrate intermittent symptoms indicative of cardiac disease and require cardiac monitoring on a continuing basis for up to 30 days. The device continuously records ECG data and upon detection by an ECG analysis algorithm or manually initiated by the patient, automatically delivers the recorded cardiac activity to the server where…

Read the full statement (141 words)

The bioflux Device is intended for use by patients who either have or are at risk of having cardiac disease and those that demonstrate intermittent symptoms indicative of cardiac disease and require cardiac monitoring on a continuing basis for up to 30 days. The device continuously records ECG data and upon detection by an ECG analysis algorithm or manually initiated by the patient, automatically delivers the recorded cardiac activity to the server where it is presented and can be reviewed by a medical professional.

The data received from the bioflux device can be used by another device for arrhythmia analysis, reporting and signal measurements. The bioflux device is not intended to sound any alarms. The device does not deliver any therapy, administer any drugs, provide interpretive or diagnostic statements or provide for any life support.

bioflux is for prescription use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K172311: BioFlux Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172311

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026