510(k) · Cleared
ClearedSILC® Fixation System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Globus Medical, Inc. · OWI Bone Fixation Cerclage, Sublaminar
Cleared on Oct 26, 2017 as substantially equivalent to K133482 (Globus Medical, Inc., 2014) and 1 other predicate after a 77-day review. Its family tree reaches back 10 generations to 1995. 1 later device descends from it.
- Decided
- Oct 26, 2017
- Review
- 77 days
- Class
- Class II
- Product code
- OWI
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 10 generations to K950697 (1995). 78 ancestors in all, the oldest K781443 (1978). 1 later device descends from it, 1 citing it directly.
- Root · 10 generations backK950697 Depuy Motech Moss Miami Spinal System - Pedicle FixationDepuy Motech · 1995
- 6 generations between
- 3 generations backK120099 Range Spinal System (Mesa and Denali)K2m, Inc. · 2012
- 2 generations backK143350 Nile Alternative FixationK2m, Inc. · 2015
- 1 generation backK163181 TRANSLACE™ Spinal Tethering SystemMedtronic Sofamor Danek USA, Inc. · 2017
- This deviceK172417 SILC® Fixation SystemGlobus Medical, Inc. · 2017
- Descendant · cites it directly · 0 of its ownK230565 HILINE™ Fixation SystemGlobus Medical, Inc. · 2023
Show all 10 generations
- Root · 10 generations backK950697 Depuy Motech Moss Miami Spinal System - Pedicle FixationDepuy Motech · 1995
- 9 generations backK050461 Xia 4.5 Spinal SystemStryker Spine · 2005
- 8 generations backK052761 Modification to: Xia 4.5 Spinal SystemStryker Spine · 2005
- 7 generations backK060361 Xia Spinal System, Xia 4.5 Spinal SystemStryker Spine · 2006 · Recalled
- 6 generations backK060979 Xia Titanium and 4.5 Spinal SystemsStryker Spine · 2006
- 5 generations backK082942 Modfication to: Expedium Spine SystemDepuy Spine, Inc. · 2008
- 4 generations backK090230 Expedium Spine SystemDepuy Spine, Inc. · 2009
- 3 generations backK120099 Range Spinal System (Mesa and Denali)K2m, Inc. · 2012
- 2 generations backK143350 Nile Alternative FixationK2m, Inc. · 2015
- 1 generation backK163181 TRANSLACE™ Spinal Tethering SystemMedtronic Sofamor Danek USA, Inc. · 2017
- This deviceK172417 SILC® Fixation SystemGlobus Medical, Inc. · 2017
Most influential descendants
Showing 1 of 1 · See all- K230565HILINE™ Fixation SystemGlobus Medical, Inc. · 2023 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K950697 | Depuy Motech Moss Miami Spinal System - Pedicle Fixation | Depuy Motech | 1995 | — |
| −9 | K050461 | Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −8 | K052761 | Modification to: Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −7 | K060361 | Xia Spinal System, Xia 4.5 Spinal System | Stryker Spine | 2006 | 1 |
| −6 | K060979 | Xia Titanium and 4.5 Spinal Systems | Stryker Spine | 2006 | — |
| −5 | K082942 | Modfication to: Expedium Spine System | Depuy Spine, Inc. | 2008 | — |
| −4 | K090230 | Expedium Spine System | Depuy Spine, Inc. | 2009 | — |
| −3 | K120099 | Range Spinal System (Mesa and Denali) | K2m, Inc. | 2012 | — |
| −2 | K143350 | Nile Alternative Fixation | K2m, Inc. | 2015 | — |
| −1 | K163181 | TRANSLACE™ Spinal Tethering System | Medtronic Sofamor Danek USA, Inc. | 2017 | — |
| 0 (this device) | K172417 | SILC® Fixation System | Globus Medical, Inc. | 2017 | — |
| +1 | K230565 | HILINE™ Fixation System | Globus Medical, Inc. | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1992 | 1 | 0 |
| 1993 | 2 | 0 |
| 1994 | 1 | 0 |
| 1996 | 3 | 0 |
| 1997 | 3 | 0 |
| 1998 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 5 | 0 |
| 2001 | 6 | 0 |
| 2002 | 1 | 0 |
| 2003 | 6 | 0 |
| 2004 | 6 | 0 |
| 2005 | 6 | 0 |
| 2006 | 4 | 0 |
| 2007 | 2 | 0 |
| 2008 | 7 | 0 |
| 2009 | 2 | 0 |
| 2010 | 1 | 0 |
| 2011 | 3 | 0 |
| 2012 | 2 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2023 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OWI device
- #1 K253615 Invictus Bands Systemscore 20.7 · 33 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K133482 | Silc Fixation SystemSummary page 4…0 Bone Fixation Cerclage Product Code OWI Regulatory Class II, Panel Code 87 Predicate(s): Primary: SILC® Fixation System (K133482) Additional: Medtronic TRANSLACE™ Spinal Tethering System (K163181) Purpose: The purpose… | 2014 |
| * | K163181 | TRANSLACE™ Spinal Tethering SystemSummary page 4…l Code 87 Predicate(s): Primary: SILC® Fixation System (K133482) Additional: Medtronic TRANSLACE™ Spinal Tethering System (K163181) Purpose: The purpose of this submission is to request clearance for additional implants of the SILC® Fixation System. Device De… | 2017 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K230565 | HILINE™ Fixation System | 2023 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 6 companies; a new generation was cleared every 2.2 years on median.
- 3 of the 78 ancestors have a recall of any class.
- Of its descendants, K230565 (Globus Medical, Inc., 2023) has gone furthest, with 0 descendants of its own.
- 2 other devices also cite its predicate K133482.
How does its category compare?
All OWI devicesOWI Bone Fixation Cerclage, Sublaminar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.
FDA decisions per year · OWI
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · OWI
60in 2020
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OWI
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OWI
6in 2025
MAUDE reports naming product code OWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 2 | — | 0 | 0 |
| 2014 | 3 | 92 | 0 | 1 |
| 2015 | 3 | 93 | 0 | 1 |
| 2016 | 5 | 98 | 0 | 6 |
| 2017 | 7 | 77 | 0 | 6 |
| 2018 | 4 | 156 | 0 | 2 |
| 2019 | 3 | 51 | 0 | 13 |
| 2020 | 3 | 60 | 1 | 8 |
| 2021 | 1 | — | 0 | 5 |
| 2022 | 1 | — | 0 | 6 |
| 2023 | 2 | — | 0 | 4 |
| 2024 | 0 | — | 0 | 3 |
| 2025 | 0 | — | 0 | 6 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The SILC® Fixation System consists of temporary implants for use in orthopedic surgery. The system is intended to provide temporary stabilization as a bone anchor during the development of solid bony fusion and aid in the repair of bone fractures. The indications for use include the following applications: * Spinal trauma surgery, used in sublaminar, interspinous, or facet wiring techniques; * Spinal reconstructive surgery, incorporated into constructs…
Read the full statement (132 words)
The SILC® Fixation System consists of temporary implants for use in orthopedic surgery. The system is intended to provide temporary stabilization as a bone anchor during the development of solid bony fusion and aid in the repair of bone fractures. The indications for use include the following applications:
* Spinal trauma surgery, used in sublaminar, interspinous, or facet wiring techniques;
* Spinal reconstructive surgery, incorporated into constructs for the purpose of correction of spinal deformities such as idiopathic and neuromuscular scoliosis in patients 8 years of age and older, adult scoliosis, kyphosis, and spondylolisthesis;
* Spinal degenerative surgery, as an adjunct to spinal fusions.
The SILC® Fixation System may also be used in conjunction with other medical implants made of similar metals whenever “wiring” may help secure the attachment of other implants.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K172417 · printed Nov 6, 2026
Cite this page
510(k) Report. “K172417: SILC® Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172417
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026