510(k) Report

510(k) · Cleared

Cleared

BD Cathena Safety IV Catheter

K172506510(k) TraditionalCleared Sep 17, 201730-day reviewClass II21 CFR 880.5200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton, Dickinson and Company · FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

Cleared on Sep 17, 2017 as substantially equivalent to K110443 (Becton, Dickinson & CO, 2011) and 1 other predicate after a 30-day review. Its family tree reaches back 5 generations to 1986. 4 later devices descend from it.

Decided
Sep 17, 2017
Review
30 days
Class
Class II
Product code
FOZ
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K854773 (1986). 19 ancestors in all, the oldest K801941 (1980). 4 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 1 other ancestor2004: 1 other ancestor2002: 3 other ancestors2001: 1 other ancestor1999: 2 other ancestors1997: 1 other ancestor1981: 2 other ancestors1980: 1 other ancestor2003: 1 other ancestor1986: 1 other ancestor2020: 2 descendants cleared2022: 1 descendant cleared2025: 1 descendant clearedK854773 · Supercath a.V. Fistula · Togo Medikit Co., Ltd. · 1986K050114 · Supercath Z3V · Togo Medikit Co., Ltd. · 2005K081953 · Supercath 5 · Togo Medikit Co., Ltd. · 2009K093546 · Supercath 5 Model SP120-XX-XX, SP125-XX-XX · Togo Medikit Co., Ltd. · 2009K110443 · BD Insyte Autoguard BC · Becton, Dickinson & CO · 201119801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 4 other ancestors3 generations back: 6 other ancestors4 generations back: 1 other ancestor5 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant4 generations forward: 1 descendant K110443 · BD Insyte Autoguard BC · Becton, Dickinson & CO · 2011K093546 · Supercath 5 Model SP120-XX-XX, SP125-XX-XX · Togo Medikit Co., Ltd. · 2009K081953 · Supercath 5 · Togo Medikit Co., Ltd. · 2009K050114 · Supercath Z3V · Togo Medikit Co., Ltd. · 2005K854773 · Supercath a.V. Fistula · Togo Medikit Co., Ltd. · 1986−50
  1. Root · 5 generations backK854773 Supercath a.V. FistulaTogo Medikit Co., Ltd. · 1986
  2. 4 generations backK050114 Supercath Z3VTogo Medikit Co., Ltd. · 2005
  3. 3 generations backK081953 Supercath 5Togo Medikit Co., Ltd. · 2009
  4. 2 generations backK093546 Supercath 5 Model SP120-XX-XX, SP125-XX-XXTogo Medikit Co., Ltd. · 2009
  5. 1 generation backK110443 BD Insyte Autoguard BCBecton, Dickinson & CO · 2011
  6. This deviceK172506 BD Cathena Safety IV CatheterBecton, Dickinson and Company · 2017
  7. Descendant · cites it directly · 3 of its ownK192493 BD Cathena (TM) Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2020
  8. Descendant · 2 generations on · 2 of its ownK201717 BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2020
  9. Descendant · 3 generations on · 1 of its ownK220584 BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2022 · Recalled
  10. Descendant · 4 generations on · 0 of its ownK251155 BD Cathena™ Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2025

Most influential descendants

Showing 4 of 4 · See all
  • K192493BD Cathena (TM) Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2020 · cites it directly3descendants
  • K201717BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2020 · 2 generations on2descendants
  • K220584BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2022 · 3 generations on1descendant
  • K251155BD Cathena™ Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc. · 2025 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K854773Supercath a.V. FistulaTogo Medikit Co., Ltd.1986—
−4K050114Supercath Z3VTogo Medikit Co., Ltd.2005—
−3K081953Supercath 5Togo Medikit Co., Ltd.2009—
−2K093546Supercath 5 Model SP120-XX-XX, SP125-XX-XXTogo Medikit Co., Ltd.2009—
−1K110443BD Insyte Autoguard BCBecton, Dickinson & CO2011—
0 (this device)K172506BD Cathena Safety IV CatheterBecton, Dickinson and Company2017—
+1K192493BD Cathena (TM) Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc.2020—
+2K201717BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc.2020—
+3K220584BD Cathena Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc.20222
+4K251155BD Cathena™ Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
198120
198610
199710
199920
200110
200230
200310
200410
201110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202020
202210
202510
FIG. 1 — Lineage of K172506, 1986–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FOZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FOZ device

  1. #1 K243403 BD Nexiva™ Closed IV Catheter Systemscore 14.8 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110443BD Insyte Autoguard BC
Summary page 4
…Classification Panel: General Hospital Predicate Trade Name: BD InsyteTM AutoguardTM BC Device 510(k) Reference: K110443 (BD Insyte Common Name: Peripheral Intravascular or IV Catheter Autoguard BC) Regulation Number:…
Becton, Dickinson & CO2011—
*K111236Introcan Safety (R) 3 Closed IV Catheter 18GA X 1-3/4 (45MM) and 18GA X 1-1/4 (32MM) /…
Summary page 4
…ion Panel: General Hospital Predicate Trade Name: Introcan Safety® 3 Closed IV Catheter Device 510(k) Reference: K111236 (Introcan Safety Common Name: Peripheral Intravascular or IV Catheter 3) Regulation Number:…
B.Braun Melsungen AG20111

Also cleared against K110443: 6 other devices →

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K192493BD Cathena (TM) Safety IV CatheterBecton Dickinson Infusion Therapy Systems, Inc.20203

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 3 companies; a new generation was cleared every 3.8 years on median.
  • 6 of the 19 ancestors have a recall of any class.
  • Of its descendants, K192493 (Becton Dickinson Infusion Therapy Systems, Inc., 2020) has gone furthest, with 3 descendants of its own.
  • 6 other devices also cite its predicate K110443.

How does its category compare?

All FOZ devices

FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · FOZ

11in 2025

2007: 62008: 92009: 92010: 32011: 62012: 132013: 42014: 92015: 102016: 92017: 92018: 12019: 82020: 102021: 42022: 82023: 92024: 62025: 112026 (partial year): 7
2007high 13 (2012) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FOZ

91in 2025

2007: 159 days median2008: 103 days median2009: 30 days median2010: 28 days median2011: 132 days median2012: 122 days median2013: 104 days median2014: 99 days median2015: 107 days median2016: 63 days median2017: 51 days median2019: 140 days median2020: 191 days median2021: 242 days median2022: 183 days median2023: 129 days median2024: 190 days median2025: 91 days median2026 (partial year): 203 days median
2007high 242 (2021) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FOZ

4in 2023

2007: 162009: 232010: 1152013: 22014: 42016: 3, 1 Class I2017: 222018: 42019: 32020: 32021: 12022: 4, 2 Class I2023: 4, 2 Class I2026 (partial year): 2
2007high 115 (2010) · low 0 (2008)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · FOZ

5,110in 2025

2007: 3742008: 4222009: 5082010: 3702011: 7862012: 5602013: 6402014: 8152015: 7292016: 9252017: 1,9662018: 3,3052019: 4,3652020: 3,7972021: 4,6742022: 4,1332023: 4,4302024: 4,7722025: 5,110
2007high 5,110 (2025) · low 370 (2010)2025

MAUDE reports naming product code FOZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007615916374
200891030422
200993023508
2010328115370
201161320786
2012131220560
201341042640
20149994815
2015101070729
20169633 (1)925
2017951221,966
20181—43,305
2019814034,365
20201019133,797
2021424214,674
202281834 (2)4,133
202391294 (2)4,430
2024619004,772
2025119105,110
202672032—

What is it indicated for?

BD Cathena Safety IV Catheters are intended to be inserted into a patient’s peripheral vascular system for short term use to sample blood, monitor blood pressure, or administer fluids. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy, procedure being performed, fluids being infused, and duration of therapy. The catheters are suitable for use with power injectors set to a maximum pressure of 325 psi (2240 kPa).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172506: BD Cathena Safety IV Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172506

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026