510(k) Report

510(k) · Cleared

Cleared

Large Screws Range

K172596510(k) SpecialCleared Oct 2, 201734-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Newclip Technics · HWC Screw, Fixation, Bone

Cleared on Oct 2, 2017 as substantially equivalent to K160617 (Newclip Technics, 2016) and 2 other predicates after a 34-day review. Its family tree reaches back 6 generations to 1996. 4 later devices descend from it.

Decided
Oct 2, 2017
Review
34 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to K962823 (1996). 13 ancestors in all. 4 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor2000: 1 other ancestor2001: 1 other ancestor1997: 1 other ancestor1996: 2 other ancestors1999: 1 other ancestor2018: 1 descendant cleared2022: 1 descendant cleared2021: 1 descendant cleared2026: 1 descendant clearedReference device: K143061 · Activ Ankle Locking Plating System · Newclip Technics · 2015K962823 · Synthes Sterile 3.0 MM Cannulated Screw and Threaded Washer · Synthes (Usa) · 1996K993762 · I.CO.S Screw · New Deal, S.A. · 2000K011821 · Modification to the I.C.O.S Screw · New Deal, S.A. · 2001K050346 · Stabilization Screw · New Deal, S.A. · 2005 · recalledK071639 · Qwix Positioning Screw · Newdeal Sas · 2007 · recalledK160617 · Large Screws Range · Newclip Technics · 20161995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors3 generations back: 3 other ancestors4 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 3 descendants K160617 · Large Screws Range · Newclip Technics · 2016K071639 · Qwix Positioning Screw · Newdeal Sas · 2007 · recalledK050346 · Stabilization Screw · New Deal, S.A. · 2005 · recalledK011821 · Modification to the I.C.O.S Screw · New Deal, S.A. · 2001K993762 · I.CO.S Screw · New Deal, S.A. · 2000K962823 · Synthes Sterile 3.0 MM Cannulated Screw and Threaded Washer · Synthes (Usa) · 1996−50
  1. Root · 6 generations backK962823 Synthes Sterile 3.0 MM Cannulated Screw and Threaded WasherSynthes (Usa) · 1996
  2. 5 generations backK993762 I.CO.S ScrewNew Deal, S.A. · 2000
  3. 4 generations backK011821 Modification to the I.C.O.S ScrewNew Deal, S.A. · 2001
  4. 3 generations backK050346 Stabilization ScrewNew Deal, S.A. · 2005 · Recalled
  5. 2 generations backK071639 Qwix Positioning ScrewNewdeal Sas · 2007 · Recalled
  6. 1 generation backK160617 Large Screws RangeNewclip Technics · 2016
  7. This deviceK172596 Large Screws RangeNewclip Technics · 2017
  8. Descendant · cites it directly · 3 of its ownK173641 Activ AnkleNewclip Technics · 2018
  9. Descendant · 2 generations on · 0 of its ownK261511 Xpert AnkleNewclip Technics · 2026
  10. Descendant · 2 generations on · 0 of its ownK221395 Footmotion Plating SystemNewclip Technics · 2022
  11. Descendant · 2 generations on · 0 of its ownK213214 Xpert WristNewclip Technics · 2021

Most influential descendants

Showing 4 of 4 · See all
  • K173641Activ AnkleNewclip Technics · 2018 · cites it directly3descendants
  • K261511Xpert AnkleNewclip Technics · 2026 · 2 generations on0descendants
  • K221395Footmotion Plating SystemNewclip Technics · 2022 · 2 generations on0descendants
  • K213214Xpert WristNewclip Technics · 2021 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K962823Synthes Sterile 3.0 MM Cannulated Screw and Threaded WasherSynthes (Usa)1996—
−5K993762I.CO.S ScrewNew Deal, S.A.2000—
−4K011821Modification to the I.C.O.S ScrewNew Deal, S.A.2001—
−3K050346Stabilization ScrewNew Deal, S.A.20054
−2K071639Qwix Positioning ScrewNewdeal Sas20071
−1K160617Large Screws RangeNewclip Technics2016—
0 (this device)K172596Large Screws RangeNewclip Technics2017—
+1K173641Activ AnkleNewclip Technics2018—
+2K261511Xpert AnkleNewclip Technics2026—
+2K221395Footmotion Plating SystemNewclip Technics2022—
+2K213214Xpert WristNewclip Technics2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199710
199910
200010
200110
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202110
202210
202610
FIG. 1 — Lineage of K172596, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160617Large Screws Range
Summary page 4
…art. 888.3040) 3. Primary predicate or legally marketed devices which are substantially equivalent: x Large Screws Range of Newclip Technics (K160617) Secondary predicate or legally marketed devices which are substantially equivalent: x Asnis III Cannu…
Newclip Technics2016—
*K000080Asnis Iii Cannulated Screw System
Summary page 4
…predicate or legally marketed devices which are substantially equivalent: x Asnis III Cannulated Screw System of Howmedica Osteonics Corp. (K000080 and K024060) Reference device: x Activ Ankle Locking Plating System of Newclip Technics (K143061)…
Howmedica Osteonics Corp.20001
*K024060Modification to Asnis Iii Cannulated Screw System
Summary page 4
…legally marketed devices which are substantially equivalent: x Asnis III Cannulated Screw System of Howmedica Osteonics Corp. (K000080 and K024060) Reference device: x Activ Ankle Locking Plating System of Newclip Technics (K143061)…
Howmedica Osteonics Corp.2002—
†K143061Activ Ankle Locking Plating SystemNewclip Technics2015—

Also cleared against K160617: 1 other device →

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173641Activ AnkleNewclip Technics20183

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 4 companies; a new generation was cleared every 3.3 years on median.
  • 3 of the 13 ancestors have a recall of any class.
  • Of its descendants, K173641 (Newclip Technics, 2018) has gone furthest, with 3 descendants of its own.
  • 1 other device also cites its predicate K160617.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

The Large Screws range is indicated for the fixation of bone fractures, pseudarthroses, fusions and osteotomies of foot and ankle as well as medium and large bone fragments including radius, humerus, femur, tibia in adults.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K172596: Large Screws Range.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172596

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026