ClearedArm Type Automatic Blood Pressure Monitor BP310A, BP313A, BP351A, BP362A, BP366A, BP369A, BP380A, BP389A, BP-JC312
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shenzhen Jiacom Technology CO ., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive
Cleared on Jan 26, 2018 as substantially equivalent to K131558 (Shenzhen Pango Electronic Co., Ltd., 2013) after a 126-day review. Its family tree reaches back 5 generations to 2000.
- Decided
- Jan 26, 2018
- Review
- 126 days
- Class
- Class II
- Product code
- DXN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K001670 (2000). No later device cites it as a predicate yet.
- Root · 5 generations backK001670 Automatic Blood Pressure Monitor with Intellisense, Model Hem-757Omron Healthcare, Inc. · 2000
- 4 generations backK030358 KD-622 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co., · 2003
- 3 generations backK070828 KD-595 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co., · 2007
- 2 generations backK102988 Electronic Blood Presure MonitorShenzhen Pango Electronic Co., Ltd. · 2010
- 1 generation backK131558 PG-800B Series, Including PG-800BD, PG-800B-1, PG-800BD-1, PG-800B3…Shenzhen Pango Electronic Co., Ltd. · 2013
- This deviceK172896 Arm Type Automatic Blood Pressure Monitor BP310A, BP313A, BP351A…Shenzhen Jiacom Technology CO ., Ltd. · 2018
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K001670 | Automatic Blood Pressure Monitor with Intellisense, Model Hem-757 | Omron Healthcare, Inc. | 2000 | — |
| −4 | K030358 | KD-622 Fully Automatic Electronic Blood Pressure Monitor | Kodon (Tianjin)Electronic&Electrical Apparatus Co., | 2003 | — |
| −3 | K070828 | KD-595 Fully Automatic Electronic Blood Pressure Monitor | Kodon (Tianjin)Electronic&Electrical Apparatus Co., | 2007 | — |
| −2 | K102988 | Electronic Blood Presure Monitor | Shenzhen Pango Electronic Co., Ltd. | 2010 | — |
| −1 | K131558 | PG-800B Series, Including PG-800BD, PG-800B-1, PG-800BD-1, PG-800B3, PG-800B4… | Shenzhen Pango Electronic Co., Ltd. | 2013 | — |
| 0 (this device) | K172896 | Arm Type Automatic Blood Pressure Monitor BP310A, BP313A, BP351A, BP362A… | Shenzhen Jiacom Technology CO ., Ltd. | 2018 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DXN device
- #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K131558 | PG-800B Series, Including PG-800BD, PG-800B-1, PG-800BD-1, PG-800B3, PG-800B4…Summary page 6…) Summary Ref.: M0792016-arm 5. Identification of Predicate Device 510(k) Number: K131558 Product Name: Electronic Blood Pressure Monitor 6. Non-Clinical Test Conclusion Non clinical tests were conducted… | 2013 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 4 companies; a new generation was cleared every 3.3 years on median.
- None of the 5 ancestors has a recall.
- 2 other devices also cite its predicate K131558.
How does its category compare?
All DXN devicesDXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · DXN
28in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXN
142in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DXN
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXN
239in 2025
MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 118 | 0 | 21 |
| 2008 | 23 | 82 | 1 | 8 |
| 2009 | 46 | 73 | 3 | 17 |
| 2010 | 43 | 94 | 0 | 14 |
| 2011 | 34 | 72 | 1 | 10 |
| 2012 | 36 | 116 | 0 | 19 |
| 2013 | 34 | 150 | 1 | 72 |
| 2014 | 29 | 133 | 0 | 47 |
| 2015 | 30 | 97 | 0 | 62 |
| 2016 | 30 | 144 | 1 | 54 |
| 2017 | 33 | 184 | 0 | 90 |
| 2018 | 22 | 235 | 0 | 617 |
| 2019 | 33 | 156 | 1 | 96 |
| 2020 | 24 | 198 | 0 | 130 |
| 2021 | 23 | 190 | 0 | 162 |
| 2022 | 25 | 137 | 0 | 155 |
| 2023 | 35 | 182 | 0 | 162 |
| 2024 | 17 | 107 | 3 | 270 |
| 2025 | 28 | 142 | 0 | 239 |
| 2026 | 29 | 147 | 0 | — |
What is it indicated for?
Arm Type Automatic Blood Pressure Monitor is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population via non-invasive oscillometric technique in which an inflatable cuff is wrapped around the arm. It can be used at medical facilities or at home. The intended arm circumference is 22-32 cm.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K172896 · printed Nov 6, 2026
Cite this page
510(k) Report. “K172896: Arm Type Automatic Blood Pressure Monitor BP310A, BP313A, BP351A, BP362A, BP366A, BP369A, BP380A, BP389A, BP-JC312.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172896
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026