510(k) · Cleared
ClearedMedline Disposable Electronic Thermometer Probe Cover
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medline Industries, Inc. · FLL Continuous Measurement Thermometer
Cleared on Jan 17, 2018 as substantially equivalent to K030580 (Welch Allyn, Inc., 2003) after a 110-day review. Its family tree reaches back 1 generation to 2003.
- Decided
- Jan 17, 2018
- Review
- 110 days
- Class
- Class II
- Product code
- FLL
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K030580 (2003). No later device cites it as a predicate yet.
- Root · 1 generation backK030580 Suretemp PlusWelch Allyn, Inc. · 2003 · Recalled
- This deviceK173113 Medline Disposable Electronic Thermometer Probe CoverMedline Industries, Inc. · 2018
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K030580 | Suretemp Plus | Welch Allyn, Inc. | 2003 | 1 |
| 0 (this device) | K173113 | Medline Disposable Electronic Thermometer Probe Cover | Medline Industries, Inc. | 2018 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FLL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FLL device
- #1 K191829 Microlife Non-Contact Infrared Forehead…score 26.7 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K030580 | Suretemp PlusSummary page 4…roduct Code: FLL Classification Panel: General Hospital Device Class: Class II Regulation #: 21 CFR 880.2910 Predicate Device The Welch Allyn SureTemp Plus Thermometer (K030580) is identified herein as the predicate device of the Medline Disposable Electronic Thermometer Probe Cover. Please note that the… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has a recall.
- 1 other device also cites its predicate K030580.
How does its category compare?
All FLL devicesFLL Continuous Measurement Thermometer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · FLL
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FLL
131in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FLL
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FLL
73in 2025
MAUDE reports naming product code FLL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 81 | 0 | 4 |
| 2008 | 14 | 59 | 0 | 13 |
| 2009 | 13 | 84 | 0 | 9 |
| 2010 | 24 | 88 | 0 | 9 |
| 2011 | 20 | 113 | 1 | 18 |
| 2012 | 17 | 126 | 0 | 26 |
| 2013 | 14 | 149 | 0 | 16 |
| 2014 | 7 | 199 | 0 | 54 |
| 2015 | 3 | 270 | 1 | 53 |
| 2016 | 22 | 157 | 0 | 58 |
| 2017 | 16 | 174 | 2 | 118 |
| 2018 | 35 | 209 | 1 | 51 |
| 2019 | 22 | 198 | 5 | 52 |
| 2020 | 21 | 194 | 0 | 53 |
| 2021 | 43 | 218 | 0 | 115 |
| 2022 | 24 | 218 | 0 | 142 |
| 2023 | 17 | 295 | 0 | 101 |
| 2024 | 13 | 223 | 0 | 118 |
| 2025 | 6 | 131 | 1 | 73 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
The Medline Disposable Electronic Thermometer Probe Covers are intended for use as barriers between any SureTemp and SureTemp Plus digital thermometer probe and users' oral, rectal, or axillary measuring sites to avoid possible contamination and infection during temperature measuring. The probe covers are non-sterile and intended for single use only.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K173113 · printed Nov 6, 2026
Cite this page
510(k) Report. “K173113: Medline Disposable Electronic Thermometer Probe Cover.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173113
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026