510(k) Report

510(k) · Cleared

Cleared

ToxCO

K173238510(k) TraditionalCleared Apr 4, 2019546-day reviewClass II21 CFR 868.1430

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bedfont Scientific, Ltd. · CCJ Analyzer, Gas, Carbon-Monoxide, Gaseous-Phase

Cleared on Apr 4, 2019 as substantially equivalent to K082315 (Bedfont Scientific, Ltd., 2010) after a 546-day review. Its family tree reaches back 1 generation to 2010.

Decided
Apr 4, 2019
Review
546 days
Class
Class II
Product code
CCJ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K082315 (2010). No later device cites it as a predicate yet.

K082315 · EC50 Micro+ Smokerlyzer · Bedfont Scientific, Ltd. · 20100
  1. Root · 1 generation backK082315 EC50 Micro+ SmokerlyzerBedfont Scientific, Ltd. · 2010
  2. This deviceK173238 ToxCOBedfont Scientific, Ltd. · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K082315EC50 Micro+ SmokerlyzerBedfont Scientific, Ltd.2010—
0 (this device)K173238ToxCOBedfont Scientific, Ltd.2019—
FIG. 1 — Lineage of K173238, 2010–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCJ device

  1. #1 K253119 CoSense ETCO Monitorscore 12.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082315EC50 Micro+ Smokerlyzer
Summary page 5
…: Bedfont Scientific Ltd Device Trade Name: Micro+™ Smokerlyzer Device 510(k): K082315 Reference only Predicate Device Manufacturer: Bedfont Scientific Ltd Device T…
Bedfont Scientific, Ltd.2010—
†K070259EC50 Toxco+ Breath Carbon Monoxide MonitorBedfont Scientific, Ltd.2008—

Also cleared against K082315: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K082315.

How does its category compare?

All CCJ devices

CCJ Analyzer, Gas, Carbon-Monoxide, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · CCJ

2in 2021

2008: 22010: 12012: 12014: 12015: 12017: 12018: 12019: 12021: 22026 (partial year): 1
2007high 2 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCJ

Too few CCJ 510(k)s in any year since 2007 to give a median.

Recalls per year · CCJ

No recall names CCJ since 2007.

Adverse event reports per year · CCJ

No MAUDE report names CCJ since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—00
20090—00
20101—00
20110—00
20121—00
20130—00
20141—00
20151—00
20160—00
20171—00
20181—00
20191—00
20200—00
20212—00
20220—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

The ToxCO® breath Carbon Monoxide monitor and accessories are used by healthcare professionals to determine levels of Carbon Monoxide (CO) poisoning.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K173238: ToxCO.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173238

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026