510(k) · Cleared
ClearedRetiCapture
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ilooda Co,., Ltd. · HKI Camera, Ophthalmic, Ac-Powered
Cleared on Jul 27, 2018 as substantially equivalent to K120982 (Medimaging Integrated Solutions, Inc. (Miis), 2012) after a 260-day review. Its family tree reaches back 4 generations to 2001.
- Decided
- Jul 27, 2018
- Review
- 260 days
- Class
- Class II
- Product code
- HKI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K003376 (2001). 5 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK003376 Welch Allyn 11800 OpthalmoscopeWelch Allyn, Inc. · 2001
- 3 generations backK092056 Optomed Smartscope, Model M3-1 EY1Optomed OY · 2009
- 2 generations backK110986 Optomed Smartscope M5 EY3 and M5 ES1Optomed OY · 2011
- 1 generation backK120982 Digital Eye-Fundus CameraMedimaging Integrated Solutions, Inc. (Miis) · 2012
- This deviceK173474 RetiCaptureIlooda Co,., Ltd. · 2018
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K003376 | Welch Allyn 11800 Opthalmoscope | Welch Allyn, Inc. | 2001 | — |
| −3 | K092056 | Optomed Smartscope, Model M3-1 EY1 | Optomed OY | 2009 | — |
| −2 | K110986 | Optomed Smartscope M5 EY3 and M5 ES1 | Optomed OY | 2011 | — |
| −1 | K120982 | Digital Eye-Fundus Camera | Medimaging Integrated Solutions, Inc. (Miis) | 2012 | — |
| 0 (this device) | K173474 | RetiCapture | Ilooda Co,., Ltd. | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HKI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HKI device
- #1 K253176 TearViewscore 12.7 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K120982 | Digital Eye-Fundus CameraSummary page 4…e devices Applicant Device Name 510(k) Number Medimaging Integrated MiiS Horus Scope DEC 100 K120982 Solution Inc. 1… | 2012 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 5.8 years on median.
- None of the 5 ancestors has a recall.
- 2 other devices also cite its predicate K120982.
How does its category compare?
All HKI devicesHKI Camera, Ophthalmic, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · HKI
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HKI
167in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HKI
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HKI
1in 2023
MAUDE reports naming product code HKI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 3 |
| 2008 | 5 | 29 | 0 | 1 |
| 2009 | 11 | 104 | 0 | 1 |
| 2010 | 6 | 140 | 0 | 0 |
| 2011 | 7 | 160 | 0 | 0 |
| 2012 | 5 | 179 | 1 | 2 |
| 2013 | 7 | 141 | 0 | 22 |
| 2014 | 4 | 135 | 0 | 3 |
| 2015 | 0 | — | 0 | 3 |
| 2016 | 4 | 146 | 1 | 66 |
| 2017 | 2 | — | 1 | 20 |
| 2018 | 6 | 71 | 1 | 14 |
| 2019 | 4 | 73 | 0 | 0 |
| 2020 | 5 | 182 | 0 | 5 |
| 2021 | 4 | 155 | 0 | 3 |
| 2022 | 1 | — | 0 | 1 |
| 2023 | 5 | 259 | 0 | 1 |
| 2024 | 3 | 28 | 0 | 0 |
| 2025 | 4 | 167 | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
RetiCapture is a digital hand-held (portable) eye-fundus camera used to record digital photographs and video of fundus of the human eye and surrounding area.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K173474 · printed Nov 6, 2026
Cite this page
510(k) Report. “K173474: RetiCapture.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173474
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026