510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Merit Pursue Microcatheter

K173548510(k) TraditionalCleared Mar 30, 2018134-day reviewClass II21 CFR 870.1250Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Merit Medical Systems, Inc. · DQY Catheter, Percutaneous

Cleared on Mar 30, 2018 as substantially equivalent to K042568 (Boston Scientific Corp, 2004) after a 134-day review. Its family tree reaches back 4 generations to 1996. It has been recalled once.

Decided
Mar 30, 2018
Review
134 days
Class
Class II
Product code
DQY
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to K960806 (1996). 5 ancestors in all, the oldest K925813 (1994). No later device cites it as a predicate yet.

  1. Root · 4 generations backK960806 Turbo TrackerTarget Therapeutics · 1996
  2. 3 generations backK994155 Excelsior 1018 MicrocatheterBoston Scientific, Target · 2000
  3. 2 generations backK013789 Excelsior SL-10 Microcatheter, Models 168581, 168381, 168181, 168189Boston Scientific, Target · 2001 · Recalled
  4. 1 generation backK042568 Excelsior 1018 and SL-10 MicrocathetersBoston Scientific Corp · 2004 · Recalled
  5. This deviceK173548 Merit Pursue MicrocatheterMerit Medical Systems, Inc. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K960806Turbo TrackerTarget Therapeutics1996—
−3K994155Excelsior 1018 MicrocatheterBoston Scientific, Target2000—
−2K013789Excelsior SL-10 Microcatheter, Models 168581, 168381, 168181, 168189Boston Scientific, Target20012
−1K042568Excelsior 1018 and SL-10 MicrocathetersBoston Scientific Corp20047
0 (this device)K173548Merit Pursue MicrocatheterMerit Medical Systems, Inc.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
FIG. 1 — Lineage of K173548, 1996–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042568Excelsior 1018 and SL-10 Microcatheters
Summary page 4
…-Shaped Microcatheter Classification Name: Percutaneous catheter Premarket Notification: K042568 Manufacturer: Stryker Predicate Premarket Notification Reference Predicate #2: Device…
Boston Scientific Corp20047
†K172081Maestro MicrocatheterMerit Medical Systems, Inc.20171

Also cleared against K042568: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 6, 2023Class IIZ-0628-2024Package design/selectionThe sterility of microcatheter and infusion system devices cannot be guaranteed.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 4.3 years on median.
  • 2 of the 5 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K042568.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The Microcatheter is intended for general intravascular use, including peripheral and coronary vasculature. Once the subselective region has been accessed, the Microcatheter can be used for the controlled and selective infusion of diagnostics, embolic, or therapeutic materials into vessels. The catheter should not be used in the cerebral vessels.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K173548: Merit Pursue Microcatheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K173548

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026