510(k) Report

510(k) · Cleared

Cleared

Catalyst CSR 3 Peg Glenoids

K173812510(k) TraditionalCleared Mar 9, 201884-day reviewClass II21 CFR 888.3650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Catalyst Orthoscience, Inc. · KWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

Cleared on Mar 9, 2018 as substantially equivalent to K152825 (Catalyst Orthoscience, LLC, 2016) and 2 other predicates after an 84-day review. Its family tree reaches back 12 generations to 1993. 1 later device descends from it.

Decided
Mar 9, 2018
Review
84 days
Class
Class II
Product code
KWT
Recalls
None
Predicates
3

Its longest line of descent runs back 12 generations to K920362 (1993). 84 ancestors in all, the oldest K790987 (1979). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1998: 2 other ancestors2013: 1 other ancestor2011: 1 other ancestor2009: 2 other ancestors2003: 6 other ancestors2000: 6 other ancestors2010: 1 other ancestor2007: 2 other ancestors2006: 5 other ancestors2005: 1 other ancestor2001: 10 other ancestors1999: 9 other ancestors1995: 2 other ancestors1991: 3 other ancestors2004: 6 other ancestors2002: 1 other ancestor1997: 1 other ancestor1996: 4 other ancestors1994: 2 other ancestors1992: 2 other ancestors1987: 2 other ancestors1980: 2 other ancestors1979: 1 other ancestor2019: 1 descendant clearedK920362 · 3M Modular Shoulder System · 3M Health Care, Ltd. · 1993K002683 · WMT Ultra-Fit Modular Shoulder System · Wrightmedicaltechnologyinc · 2000K032679 · Aequalis Shoulder Fracture System · Tornier · 2003K043077 · Modification to Aequalis Shoulder Fracture System; Aequalis Shoulder System · Tornier · 2004K060209 · Aequalis Shoulder Fracture System & Aequalis Shoulder System · Tornier · 2006K081707 · Aequalis Shoulder Fracture and Shoulder Systems · Tornier, Inc. · 2008×3: 3 generations cleared close together, K093430 (2010), K103419 (2010), K111379 (2011) K121220 · Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/Right · Exactech, Inc. · 2012 · recalledK150583 · Aequalis PerFORM+ Shoulder System · Tornier, Inc. · 2015K152825 · Catalyst CSR Shoulder System · Catalyst Orthoscience, LLC · 201619801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 7 other ancestors3 generations back: 14 other ancestors4 generations back: 16 other ancestors5 generations back: 20 other ancestors6 generations back: 12 other ancestors7 generations back: 2 other ancestors 1 generation forward: 1 descendant K152825 · Catalyst CSR Shoulder System · Catalyst Orthoscience, LLC · 2016K150583 · Aequalis PerFORM+ Shoulder System · Tornier, Inc. · 2015K121220 · Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/Right · Exactech, Inc. · 2012 · recalledK111379 · Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large / Extra-Large, Left / Right · Exactech, Inc. · 2011 · recalledK103419 · Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TM · Exactech, Inc. · 2010 · recalledK093430 · Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage, Glenoid Contd. · Exactech, Inc. · 2010 · recalledK081707 · Aequalis Shoulder Fracture and Shoulder Systems · Tornier, Inc. · 2008K060209 · Aequalis Shoulder Fracture System & Aequalis Shoulder System · Tornier · 2006K043077 · Modification to Aequalis Shoulder Fracture System; Aequalis Shoulder System · Tornier · 2004K032679 · Aequalis Shoulder Fracture System · Tornier · 2003K002683 · WMT Ultra-Fit Modular Shoulder System · Wrightmedicaltechnologyinc · 2000K920362 · 3M Modular Shoulder System · 3M Health Care, Ltd. · 1993−10−50
  1. Root · 12 generations backK920362 3M Modular Shoulder System3M Health Care, Ltd. · 1993
  2. 8 generations between
  3. 3 generations backK121220 Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small…Exactech, Inc. · 2012 · Recalled
  4. 2 generations backK150583 Aequalis PerFORM+ Shoulder SystemTornier, Inc. · 2015
  5. 1 generation backK152825 Catalyst CSR Shoulder SystemCatalyst Orthoscience, LLC · 2016
  6. This deviceK173812 Catalyst CSR 3 Peg GlenoidsCatalyst Orthoscience, Inc. · 2018
  7. Descendant · cites it directly · 0 of its ownK191811 Catalyst OrthoScience CSR Shoulder SystemCatalyst Orthoscience, Inc. · 2019
Show all 12 generations
  1. Root · 12 generations backK920362 3M Modular Shoulder System3M Health Care, Ltd. · 1993
  2. 11 generations backK002683 WMT Ultra-Fit Modular Shoulder SystemWrightmedicaltechnologyinc · 2000
  3. 10 generations backK032679 Aequalis Shoulder Fracture SystemTornier · 2003
  4. 9 generations backK043077 Modification to Aequalis Shoulder Fracture System; Aequalis Shoulder…Tornier · 2004
  5. 8 generations backK060209 Aequalis Shoulder Fracture System & Aequalis Shoulder SystemTornier · 2006
  6. 7 generations backK081707 Aequalis Shoulder Fracture and Shoulder SystemsTornier, Inc. · 2008
  7. 6 generations backK093430 Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech…Exactech, Inc. · 2010 · Recalled
  8. 5 generations backK103419 Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc. · 2010 · Recalled
  9. 4 generations backK111379 Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium…Exactech, Inc. · 2011 · Recalled
  10. 3 generations backK121220 Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small…Exactech, Inc. · 2012 · Recalled
  11. 2 generations backK150583 Aequalis PerFORM+ Shoulder SystemTornier, Inc. · 2015
  12. 1 generation backK152825 Catalyst CSR Shoulder SystemCatalyst Orthoscience, LLC · 2016
  13. This deviceK173812 Catalyst CSR 3 Peg GlenoidsCatalyst Orthoscience, Inc. · 2018

Most influential descendants

Showing 1 of 1 · See all
  • K191811Catalyst OrthoScience CSR Shoulder SystemCatalyst Orthoscience, Inc. · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K9203623M Modular Shoulder System3M Health Care, Ltd.1993—
−11K002683WMT Ultra-Fit Modular Shoulder SystemWrightmedicaltechnologyinc2000—
−10K032679Aequalis Shoulder Fracture SystemTornier2003—
−9K043077Modification to Aequalis Shoulder Fracture System; Aequalis Shoulder SystemTornier2004—
−8K060209Aequalis Shoulder Fracture System & Aequalis Shoulder SystemTornier2006—
−7K081707Aequalis Shoulder Fracture and Shoulder SystemsTornier, Inc.2008—
−6K093430Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage…Exactech, Inc.20101
−5K103419Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc.20102
−4K111379Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large /…Exactech, Inc.20112
−3K121220Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/RightExactech, Inc.20122
−2K150583Aequalis PerFORM+ Shoulder SystemTornier, Inc.2015—
−1K152825Catalyst CSR Shoulder SystemCatalyst Orthoscience, LLC2016—
0 (this device)K173812Catalyst CSR 3 Peg GlenoidsCatalyst Orthoscience, Inc.2018—
+1K191811Catalyst OrthoScience CSR Shoulder SystemCatalyst Orthoscience, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198020
198720
199130
199220
199420
199520
199640
199710
199820
199990
200060
2001100
200210
200360
200460
200510
200650
200720
200920
201010
201110
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K173812, 1993–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWT device

  1. #1 K231657 AGILON® XO Shoulder Replacement Systemscore 17.7 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K152825Catalyst CSR Shoulder System
Summary page 4
…ned cemented prosthesis; Class II Product Code: KWT Substantially Equivalent Devices w Catalyst OrthoScience CSR Shoulder System, K152825 w DePuy Anchor Peg Glenoid, K981487 w Tornier Aequalis PerFORM+ Shoul…
Catalyst Orthoscience, LLC2016—
*K981487Depuy Global Shoulder Glenoid
Summary page 4
…WT Substantially Equivalent Devices w Catalyst OrthoScience CSR Shoulder System, K152825 w DePuy Anchor Peg Glenoid, K981487 w Tornier Aequalis PerFORM+ Shoulder System, K150583 Device Description: The Catalyst CSR Shoulder…
DePuy Orthopaedics, Inc.1998—
*K150583Aequalis PerFORM+ Shoulder System
Summary page 4
…CSR Shoulder System, K152825 w DePuy Anchor Peg Glenoid, K981487 w Tornier Aequalis PerFORM+ Shoulder System, K150583 Device Description: The Catalyst CSR Shoulder System is a bone preserving total shoulder prosthesis designed for use in patients…
Tornier, Inc.2015—

Also cleared against K152825: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191811Catalyst OrthoScience CSR Shoulder SystemCatalyst Orthoscience, Inc.20190

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 7 companies; a new generation was cleared every 1.8 years on median.
  • 21 of the 84 ancestors have a recall of any class.
  • Of its descendants, K191811 (Catalyst Orthoscience, Inc., 2019) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K152825.

How does its category compare?

All KWT devices

KWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · KWT

4in 2025

2007: 12010: 12011: 52012: 12013: 12014: 12015: 22016: 22017: 12018: 22019: 42020: 12021: 12022: 12023: 12024: 12025: 42026 (partial year): 1
2007high 5 (2011) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWT

242in 2025

2011: 165 days median2019: 91 days median2025: 242 days median
2007high 242 (2025) · low 91 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWT

1in 2023

2008: 12010: 72012: 22013: 12016: 12017: 12018: 12019: 32023: 1
2007high 7 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWT

749in 2025

2007: 322008: 482009: 582010: 712011: 1122012: 832013: 1132014: 1682015: 1762016: 4452017: 5602018: 4802019: 4192020: 2152021: 2282022: 2732023: 3612024: 6012025: 749
2007high 749 (2025) · low 32 (2007)2025

MAUDE reports naming product code KWT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—032
20080—148
20090—058
20101—771
201151650112
20121—283
20131—1113
20141—0168
20152—0176
20162—1445
20171—1560
20182—1480
20194913419
20201—0215
20211—0228
20221—0273
20231—1361
20241—0601
202542420749
20261—0—

What is it indicated for?

The Catalyst CSR Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases of the glenohumeral joint where hemi- or total shoulder arthroplasty is determined by the surgeon to be the preferred method of treatment. The Catalyst CSR Shoulder System is intended for use in patients with the following conditions where the humeral head, neck and glenoid vault are of sufficient bone stock and the rotator cuff is intact or reconstructable.

• Osteoarthritis

• Avascular Necrosis

• Rheumatoid Arthritis

• Post-traumatic Arthritis

• Correction of functional deformity

Both components of the Catalyst CSR Shoulder System are intended for cemented use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K173812: Catalyst CSR 3 Peg Glenoids.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173812

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026