510(k) · Cleared
ClearedDRX-Revolution Nano Mobile X-ray System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Carestream Health, Inc. · IZL System, X-Ray, Mobile
Cleared on Feb 5, 2018 as substantially equivalent to K170755 (Carestream Health, Inc., 2017) after a 41-day review. Its family tree reaches back 3 generations to 2004. 2 later devices descend from it.
- Decided
- Feb 5, 2018
- Review
- 41 days
- Class
- Class II
- Product code
- IZL
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K041763 (2004). 2 later devices descend from it, 1 citing it directly.
- Root · 3 generations backK041763 Shimadzu Mobile X-Ray System Mux-100D SeriesShimadzu Corp. · 2004 · Recalled
- 2 generations backK120062 DRX-Revolution Mobile X-Ray SystemCarestream Health, Inc. · 2012 · Recalled
- 1 generation backK170755 DRX-Revolution Nano Mobile X-ray SystemCarestream Health, Inc. · 2017
- This deviceK173924 DRX-Revolution Nano Mobile X-ray SystemCarestream Health, Inc. · 2018
- Descendant · cites it directly · 1 of its ownK201488 RoverMicro-X, Ltd. · 2020
- Descendant · 2 generations on · 0 of its ownK211423 RoverMicro-X Limited · 2021 · Recalled
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K041763 | Shimadzu Mobile X-Ray System Mux-100D Series | Shimadzu Corp. | 2004 | 1 |
| −2 | K120062 | DRX-Revolution Mobile X-Ray System | Carestream Health, Inc. | 2012 | 7 |
| −1 | K170755 | DRX-Revolution Nano Mobile X-ray System | Carestream Health, Inc. | 2017 | — |
| 0 (this device) | K173924 | DRX-Revolution Nano Mobile X-ray System | Carestream Health, Inc. | 2018 | — |
| +1 | K201488 | Rover | Micro-X, Ltd. | 2020 | — |
| +2 | K211423 | Rover | Micro-X Limited | 2021 | 10 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IZL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IZL device
- #1 K242015 TOPAZ Mobile X-ray System (Models : TOPAZ-32D…score 19.9 · 19 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K170755 | DRX-Revolution Nano Mobile X-ray SystemSummary page 4…DRX- Revolution Nano Mobile X-ray System Manufactured by: Carestream Health, Inc. 510(k) No.: K170755 (June 21, 2012) Classification Regulation: 21 CFR 892.1720… | 2017 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K201488 | Rover | 2020 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 5.2 years on median.
- 2 of the 3 ancestors have a recall of any class.
- Of its descendants, K201488 (Micro-X, Ltd., 2020) has gone furthest, with 1 descendant of its own.
How does its category compare?
All IZL devicesIZL System, X-Ray, Mobile: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · IZL
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IZL
153in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IZL
47in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IZL
27in 2025
MAUDE reports naming product code IZL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 30 | 7 | 16 |
| 2008 | 4 | 49 | 0 | 27 |
| 2009 | 3 | 125 | 0 | 35 |
| 2010 | 3 | 65 | 4 | 75 |
| 2011 | 6 | 66 | 6 | 118 |
| 2012 | 3 | 83 | 5 | 24 |
| 2013 | 0 | — | 10 | 17 |
| 2014 | 7 | 104 | 4 | 51 |
| 2015 | 4 | 88 | 4 | 30 |
| 2016 | 6 | 47 | 0 | 33 |
| 2017 | 7 | 45 | 0 | 35 |
| 2018 | 8 | 47 | 0 | 27 |
| 2019 | 9 | 33 | 2 | 40 |
| 2020 | 9 | 43 | 1 | 48 |
| 2021 | 13 | 48 | 0 | 47 |
| 2022 | 16 | 89 | 1 | 32 |
| 2023 | 3 | 55 | 6 | 77 |
| 2024 | 9 | 159 | 5 | 39 |
| 2025 | 11 | 153 | 47 | 27 |
| 2026 | 6 | 157 | 5 | — |
What is it indicated for?
The device is designed to perform radiographic x-ray examinations on pediatric and adult patients, in all patient treatment areas.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K173924 · printed Nov 6, 2026
Cite this page
510(k) Report. “K173924: DRX-Revolution Nano Mobile X-ray System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173924
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026