Cook Incorporated · EZN Dilator, Catheter, Ureteral

Cleared on May 2, 2018 as substantially equivalent to K851144 (Van-Tec, Inc., 1985) after a 119-day review. Its family tree reaches back 1 generation to 1985.

Decided
May 2, 2018
Review
119 days
Class
Class II
Product code
EZN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K851144 (1985). No later device cites it as a predicate yet.

K851144 · Ureteral Dilation Set · Van-Tec, Inc. · 198519851990199520002005201020152020
K851144 · Ureteral Dilation Set · Van-Tec, Inc. · 19850
  1. Root · 1 generation backK851144 Ureteral Dilation SetVan-Tec, Inc. · 1985
  2. This deviceK180028 Cook 810 Set, Desilets-Hoffman Introducer SetCook Incorporated · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K851144Ureteral Dilation SetVan-Tec, Inc.1985—
0 (this device)K180028Cook 810 Set, Desilets-Hoffman Introducer SetCook Incorporated2018—
FIG. 1 — Lineage of K180028, 1985–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EZN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EZN device

  1. #1 K250910 Optilume® High Pressure Urological Balloon…score 10.0 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K851144Ureteral Dilation Set
Summary page 4
…EZN, Gastroenterology/Urology Predicate Device:  Boston Scientific’s 8/10 Dilator/Sheath Set, cleared for commercial distribution under 510(k) number K851144 Device Description: The Ureteral Introducer Sets is a bundle of two Ureteral Introducer Sets, composed of the Cook® 810 Set and…
Van-Tec, Inc.1985—

Also cleared against K851144: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K851144.

How does its category compare?

All EZN devices

EZN Dilator, Catheter, Ureteral: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · EZN

1in 2025

2013: 22017: 12018: 42019: 12020: 12023: 12025: 1
2007high 4 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EZN

175in 2018

2018: 175 days median
2007high 175 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EZN

9in 2007

2007: 9
2007high 9 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EZN

79in 2025

2007: 232008: 532009: 1242010: 522011: 542012: 382013: 272014: 282015: 302016: 192017: 652018: 582019: 562020: 402021: 412022: 512023: 832024: 492025: 79
2007high 124 (2009) · low 19 (2016)2025

MAUDE reports naming product code EZN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—923
20080—053
20090—0124
20100—052
20110—054
20120—038
20132—027
20140—028
20150—030
20160—019
20171—065
20184175058
20191—056
20201—040
20210—041
20220—051
20231—083
20240—049
20251—079
20260—0—

What is it indicated for?

The Cook 810 Set is used for retrograde or antegrade ureteral access and to facilitate wire guide exchange.

The Desilets-Hoffman Introducer Set is used for retrograde or antegrade ureteral access and to facilitate wire guide exchange.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K180028: Cook 810 Set, Desilets-Hoffman Introducer Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K180028

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.