510(k) Report

510(k) · Cleared

Cleared

SeaSpine NewPort Spinal System

K180176510(k) TraditionalCleared Feb 20, 201829-day reviewClass II21 CFR 888.3070

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

SeaSpine Orthopedics Corporation · NKB Thoracolumbosacral Pedicle Screw System

Cleared on Feb 20, 2018 as substantially equivalent to K161535 (SeaSpine Orthopedics Corporation, 2016) and 6 other predicates after a 29-day review. Its family tree reaches back 12 generations to 1990.

Decided
Feb 20, 2018
Review
29 days
Class
Class II
Product code
NKB
Recalls
None
Predicates
7

Its longest line of descent runs back 12 generations to K901587 (1990). 57 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2016: 1 other ancestor2009: 1 other ancestor2005: 6 other ancestors2006: 2 other ancestors2003: 6 other ancestors2002: 2 other ancestors2000: 2 other ancestors1999: 2 other ancestors1998: 1 other ancestor1997: 2 other ancestors1996: 1 other ancestor1994: 3 other ancestors2004: 3 other ancestors1995: 3 other ancestors2001: 2 other ancestors1993: 2 other ancestors1992: 5 other ancestors1990: 1 other ancestorK901587 · TSRH Sacral L-Connector · Danek Medical, Inc. · 1990K950099 · Synergy (TM) TI Posterior Spinal System · Buckman Co., Inc. · 1997×2: 2 generations cleared close together, K973836 (1998), K974749 (1998) K993503 · Haider-Ucr Spinal System · International Advanced Medical Enterprises, Inc. · 2000K021623 · Ucr Spinal System, 5.5MM, 8.0MM Screws & Instruments · Iame, Inc. · 2002K032739 · Ucr Spinal System · Seaspine · 2003K043232 · Ucr Spinal System · Seaspine · 2004 · recalledK051663 · Malibu Spinal System · Seaspine, Inc. · 2005K061342 · Malibu Spinal System · Seaspine, Inc. · 2006 · recalledK072605 · Malibu Spinal System · Seaspine, Inc. · 2007K122571 · Malibu Spinal System with the Daytona Deformity System · Seaspine, Inc. · 20121990199520002005201020152020
  1. Root · 12 generations backK901587 TSRH Sacral L-ConnectorDanek Medical, Inc. · 1990
  2. 8 generations between
  3. 3 generations backK061342 Malibu Spinal SystemSeaspine, Inc. · 2006 · Recalled
  4. 2 generations backK072605 Malibu Spinal SystemSeaspine, Inc. · 2007
  5. 1 generation backK122571 Malibu Spinal System with the Daytona Deformity SystemSeaspine, Inc. · 2012
  6. This deviceK180176 SeaSpine NewPort Spinal SystemSeaSpine Orthopedics Corporation · 2018
Show all 12 generations
  1. Root · 12 generations backK901587 TSRH Sacral L-ConnectorDanek Medical, Inc. · 1990
  2. 11 generations backK950099 Synergy (TM) TI Posterior Spinal SystemBuckman Co., Inc. · 1997
  3. 10 generations backK973836 Synergy 6.35MM SS Rod with Screws for Anterior Use, Part of the…Cross Medical Products, Inc. · 1998
  4. 9 generations backK974749 Synergy Closed Variable Locking Screw (VLS), Part of the Cross…Cross Medical Products, Inc. · 1998
  5. 8 generations backK993503 Haider-Ucr Spinal SystemInternational Advanced Medical Enterprises, Inc. · 2000
  6. 7 generations backK021623 Ucr Spinal System, 5.5MM, 8.0MM Screws & InstrumentsIame, Inc. · 2002
  7. 6 generations backK032739 Ucr Spinal SystemSeaspine · 2003
  8. 5 generations backK043232 Ucr Spinal SystemSeaspine · 2004 · Recalled
  9. 4 generations backK051663 Malibu Spinal SystemSeaspine, Inc. · 2005
  10. 3 generations backK061342 Malibu Spinal SystemSeaspine, Inc. · 2006 · Recalled
  11. 2 generations backK072605 Malibu Spinal SystemSeaspine, Inc. · 2007
  12. 1 generation backK122571 Malibu Spinal System with the Daytona Deformity SystemSeaspine, Inc. · 2012
  13. This deviceK180176 SeaSpine NewPort Spinal SystemSeaSpine Orthopedics Corporation · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K901587TSRH Sacral L-ConnectorDanek Medical, Inc.1990—
−11K950099Synergy (TM) TI Posterior Spinal SystemBuckman Co., Inc.1997—
−10K973836Synergy 6.35MM SS Rod with Screws for Anterior Use, Part of the Cross…Cross Medical Products, Inc.1998—
−9K974749Synergy Closed Variable Locking Screw (VLS), Part of the Cross Medical-Synergy…Cross Medical Products, Inc.1998—
−8K993503Haider-Ucr Spinal SystemInternational Advanced Medical Enterprises, Inc.2000—
−7K021623Ucr Spinal System, 5.5MM, 8.0MM Screws & InstrumentsIame, Inc.2002—
−6K032739Ucr Spinal SystemSeaspine2003—
−5K043232Ucr Spinal SystemSeaspine20041
−4K051663Malibu Spinal SystemSeaspine, Inc.2005—
−3K061342Malibu Spinal SystemSeaspine, Inc.20061
−2K072605Malibu Spinal SystemSeaspine, Inc.2007—
−1K122571Malibu Spinal System with the Daytona Deformity SystemSeaspine, Inc.2012—
0 (this device)K180176SeaSpine NewPort Spinal SystemSeaSpine Orthopedics Corporation2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199250
199320
199430
199530
199610
199720
199810
199920
200020
200120
200220
200360
200430
200560
200620
200910
201610
FIG. 1 — Lineage of K180176, 1990–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NKB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NKB device

  1. #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (7)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K161535SeaSpine® NewPort™ Spinal System
Summary page 4
…PREDICATE Device SeaSpine SeaSpine NewPort Spinal K161535 NKB Orthopedics System…
SeaSpine Orthopedics Corporation2016—
*K083089Newport Spinal System
Summary page 4
…Predicate Devices SeaSpine SeaSpine NewPort Spinal K083089 NKB Orthopedics System…
Seaspine, Inc.20092
*K122571Malibu Spinal System with the Daytona Deformity System
Summary page 4
…Orthopedics System Corporation K122571, K072605, SeaSpine NKB K061342, K051942,…
Seaspine, Inc.2012—
*K072605Malibu Spinal System
Summary page 4
…Orthopedics System Corporation K122571, K072605, SeaSpine NKB K061342, K051942,…
Seaspine, Inc.2007—
*K061342Malibu Spinal System
Summary page 4
…Corporation K122571, K072605, SeaSpine NKB K061342, K051942, SeaSpine Malibu System Orthopedics K051663…
Seaspine, Inc.20061
*K051942Malibu Spinal System
Summary page 4
…Corporation K122571, K072605, SeaSpine NKB K061342, K051942, SeaSpine Malibu System Orthopedics K051663…
Seaspine, Inc.200511
*K051663Malibu Spinal System
Summary page 4
…SeaSpine NKB K061342, K051942, SeaSpine Malibu System Orthopedics K051663 Corporation…
Seaspine, Inc.2005—

Also cleared against K161535: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 8 companies; a new generation was cleared every 1.3 years on median.
  • 6 of the 57 ancestors have a recall of any class.
  • 1 other device also cites its predicate K161535.

How does its category compare?

All NKB devices

NKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · NKB

24in 2025

2007: 382008: 362009: 442010: 372011: 482012: 602013: 352014: 462015: 552016: 502017: 632018: 562019: 392020: 482021: 322022: 342023: 442024: 392025: 242026 (partial year): 30
2007high 63 (2017) · low 24 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NKB

61in 2025

2007: 87 days median2008: 59 days median2009: 71 days median2010: 111 days median2011: 84 days median2012: 79 days median2013: 73 days median2014: 90 days median2015: 90 days median2016: 84 days median2017: 69 days median2018: 61 days median2019: 84 days median2020: 68 days median2021: 61 days median2022: 88 days median2023: 72 days median2024: 57 days median2025: 61 days median2026 (partial year): 91 days median
2007high 111 (2010) · low 57 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NKB

1in 2025

2007: 42008: 52009: 332010: 42011: 32012: 132014: 3, 1 Class I2015: 32016: 12017: 12018: 32019: 12020: 12022: 52023: 22024: 32025: 12026 (partial year): 3
2007high 33 (2009) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · NKB

1,171in 2025

2007: 342008: 822009: 1712010: 4622011: 5772012: 1,7472013: 1,9622014: 1,6712015: 1,4462016: 1,5852017: 1,6182018: 1,6842019: 1,9152020: 2,0762021: 1,7452022: 1,3392023: 9192024: 1,6142025: 1,171
2007high 2,076 (2020) · low 34 (2007)2025

MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073887434
20083659582
2009447133171
2010371114462
201148843577
20126079131,747
2013357301,962
201446903 (1)1,671
2015559031,446
2016508411,585
2017636911,618
2018566131,684
2019398411,915
2020486812,076
2021326101,745
2022348851,339
202344722919
2024395731,614
2025246111,171
202630913—

What is it indicated for?

The SeaSpine NewPort Spinal System is intended for posterior, non-cervical pedicle fixation to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine for the following indications: - Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc…

Read the full statement (150 words)

The SeaSpine NewPort Spinal System is intended for posterior, non-cervical pedicle fixation to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine for the following indications:

- Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies,

- Severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusions by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion,

- spondylolisthesis,

- trauma (i.e., fracture or dislocation),

- spinal stenosis,

- deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis),

- spinal tumor,

- pseudoarthrosis, and/or

- failed previous fusion.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K180176: SeaSpine NewPort Spinal System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K180176

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026