# K180560: Sherlock 3CG+ T ip Confirmation System

- Pathway: 510(k) (Traditional)
- Applicant: C.R. Bard, Inc.
- Decided: Jun 18, 2018 after 109 days
- Product code: LJS (Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days)
- Device class: 2
- Regulation: 21 CFR 880.5970
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 12 generations back to K001901 (2000). 36 ancestors in all.
1 later device descends from it; 1 cites it directly.
0 of 38 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K141634: Nautilus Delta, Romedex International Srl (2015) Summary page 4.
- K140345: The Sherlock 3CG Tip Confirmation System (TCS), C.R. Bard, Inc. (2014) Summary page 4.

## Most influential descendants
- K252792: PM2™ System with ECGuide™ Connector (2025), 0 descendants of its own

## Indications for use
The Sherlock 3CG+™ Tip Confirmation System (TCS) is indicated for navigation and positioning of central venous access devices (CVADs) of at least 2 Fr in size. The Sherlock 3CG+™ TCS provides real-time catheter tip location information by using catheter navigation technology along with the patient's cardiac electrical activity and is indicated for use as an alternative method to chest X-ray and fluoroscopy for CVAD tip placement confirmation of approaches from the superior vena cava. In adult patients and in adolescents (greater than 12 through 21 years of age), the Sherlock 3CG+™ TCS can be used with CVADs such as peripherally inserted central catheters (PICCs), central venous catheters (CVCs), implantable ports, and hemodialysis catheters; in children (greater than 2 to 12 years of age), in infants (greater than 1 month to 2 years of age), and in neonates (from birth to 1 month of age), the Sherlock 3CG+™ TCS can be used with PICCs and with centrally inserted central catheters (CICCs). In each specific age group, the CVAD type and size must be chosen and the CVAD must be used according to the CVAD’s indications and instructions for use. Limiting but not contraindicated situations for this method are in patients where alterations of cardiac rhythm change the presentation of the P-wave as in atrial fibrillation, atrial flutter, severe tachycardia, and pacemaker driven rhythm. In such patients, who are easily identifiable prior to catheter insertion, the use of an additional method is required to confirm catheter tip location.