510(k) · Cleared
ClearedHalo Closed Vial Adaptor (Multiple Models based on 13, 20 or 28mm Vial Neck Size), Halo Closed Syringe Adaptor, Halo Closed Line Adaptor, Closed Vial Adaptor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
J & J Solutions, Inc. D/B/A/ Corvida Medical · ONB Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System
Cleared on Aug 17, 2018 as substantially equivalent to K150486 (J & J Solutions, Inc. D/B/A/ Corvida Medical, 2015) after a 165-day review. Its family tree reaches back 9 generations to 1988.
- Decided
- Aug 17, 2018
- Review
- 165 days
- Class
- Class II
- Product code
- ONB
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K883614 (1988). 16 ancestors in all. No later device cites it as a predicate yet.
- Root · 9 generations backK883614 Cytoguard (R)Survival Technology, Inc. · 1988
- 5 generations between
- 3 generations backK123213 BD Phaseal Closed System Transfer DeviceBecton, Dickinson & CO · 2013 · Recalled
- 2 generations backK130197 BD Phaseal Closed System Transfer Device - P55Becton, Dickinson and Company · 2013 · Recalled
- 1 generation backK150486 HaloJ & J Solutions, Inc. D/B/A/ Corvida Medical · 2015 · Recalled
- This deviceK180574 Halo Closed Vial Adaptor (Multiple Models based on 13, 20 or 28mm…J & J Solutions, Inc. D/B/A/ Corvida Medical · 2018
Show all 9 generations
- Root · 9 generations backK883614 Cytoguard (R)Survival Technology, Inc. · 1988
- 8 generations backK972527 Phaseal, System for Sealed Handling of Chemotherapeutic AgentsQuality System Consulting · 1997
- 7 generations backK980381 Phaseal, Closed System Forhandling of Parenteral Drugs, Additional…Carmel Pharma Ab. · 1998
- 6 generations backK023747 PhasealCarmel Pharma Ab. · 2002
- 5 generations backK110023 Infusion Adapter C100Carmel Pharma Ab. · 2011
- 4 generations backK120384 Protector, Injector, ConnectorBd Medical-Medical Surgical Systems · 2012
- 3 generations backK123213 BD Phaseal Closed System Transfer DeviceBecton, Dickinson & CO · 2013 · Recalled
- 2 generations backK130197 BD Phaseal Closed System Transfer Device - P55Becton, Dickinson and Company · 2013 · Recalled
- 1 generation backK150486 HaloJ & J Solutions, Inc. D/B/A/ Corvida Medical · 2015 · Recalled
- This deviceK180574 Halo Closed Vial Adaptor (Multiple Models based on 13, 20 or 28mm…J & J Solutions, Inc. D/B/A/ Corvida Medical · 2018
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K883614 | Cytoguard (R) | Survival Technology, Inc. | 1988 | — |
| −8 | K972527 | Phaseal, System for Sealed Handling of Chemotherapeutic Agents | Quality System Consulting | 1997 | — |
| −7 | K980381 | Phaseal, Closed System Forhandling of Parenteral Drugs, Additional… | Carmel Pharma Ab. | 1998 | — |
| −6 | K023747 | Phaseal | Carmel Pharma Ab. | 2002 | — |
| −5 | K110023 | Infusion Adapter C100 | Carmel Pharma Ab. | 2011 | — |
| −4 | K120384 | Protector, Injector, Connector | Bd Medical-Medical Surgical Systems | 2012 | — |
| −3 | K123213 | BD Phaseal Closed System Transfer Device | Becton, Dickinson & CO | 2013 | 2 |
| −2 | K130197 | BD Phaseal Closed System Transfer Device - P55 | Becton, Dickinson and Company | 2013 | 1 |
| −1 | K150486 | Halo | J & J Solutions, Inc. D/B/A/ Corvida Medical | 2015 | 1 |
| 0 (this device) | K180574 | Halo Closed Vial Adaptor (Multiple Models based on 13, 20 or 28mm Vial Neck… | J & J Solutions, Inc. D/B/A/ Corvida Medical | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1995 | 1 | 0 |
| 2000 | 1 | 0 |
| 2006 | 1 | 0 |
| 2009 | 2 | 0 |
| 2014 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ONB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ONB device
- #1 K240171 ProSeal™ Injector Plus (Model no. 421050)score 18.2 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K150486 | HaloSummary page 5…21 CFR 880.5440 MANUFACTURER Corvida Medical 2945 Lone Oak Drive, Suite 150 Eagan, Minnesota 55121 PREDICATE DEVICE Trade Name: Halo® (K150486) Common/Usual Name: Closed Antineoplastic and Hazardous Drug Reconstitution and Transfer… | 2015 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 30 years and passes through 7 companies; a new generation was cleared every 2.4 years on median.
- 6 of the 16 ancestors have a recall of any class.
How does its category compare?
All ONB devicesONB Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · ONB
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ONB
60in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · ONB
38in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · ONB
934in 2025
MAUDE reports naming product code ONB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 1 |
| 2013 | 3 | 58 | 0 | 2 |
| 2014 | 2 | — | 0 | 3 |
| 2015 | 3 | 235 | 0 | 4 |
| 2016 | 0 | — | 1 | 13 |
| 2017 | 2 | — | 0 | 66 |
| 2018 | 6 | 249 | 0 | 228 |
| 2019 | 1 | — | 1 (1) | 464 |
| 2020 | 3 | 213 | 4 | 442 |
| 2021 | 3 | 277 | 0 | 548 |
| 2022 | 1 | — | 1 | 448 |
| 2023 | 3 | 175 | 1 | 456 |
| 2024 | 8 | 102 | 1 | 686 |
| 2025 | 6 | 60 | 38 | 934 |
| 2026 | 0 | — | 3 | — |
What is it indicated for?
The Halo® system is an airtight and leak proof closed system drug transfer device (CSTD) that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug or vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills. The Halo® system also prevents microbial ingress for up to 7 days.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K180574 · printed Nov 5, 2026
Cite this page
510(k) Report. “K180574: Halo Closed Vial Adaptor (Multiple Models based on 13, 20 or 28mm Vial Neck Size), Halo Closed Syringe Adaptor, Halo Closed Line Adaptor, Closed Vial Adaptor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K180574
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026