510(k) · Cleared
ClearedTrueDorsal Devices
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
True Function Laboratory, Inc. · LRK Device, Anti-Snoring
Cleared on Feb 11, 2019 after a 332-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Feb 11, 2019
- Review
- 332 days
- Class
- Class II
- Product code
- LRK
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LRK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LRK device
- #1 K252531 Myosa (S1H, S1, S2, S3, S1M, S2M); Myosa for…score 16.3 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LRK devicesLRK Device, Anti-Snoring: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · LRK
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LRK
107in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LRK
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LRK
653in 2025
MAUDE reports naming product code LRK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 3 | 109 | 0 | 1 |
| 2009 | 3 | 88 | 2 | 11 |
| 2010 | 8 | 195 | 0 | 7 |
| 2011 | 10 | 134 | 0 | 69 |
| 2012 | 10 | 142 | 0 | 445 |
| 2013 | 9 | 233 | 0 | 72 |
| 2014 | 11 | 219 | 0 | 49 |
| 2015 | 6 | 117 | 0 | 28 |
| 2016 | 10 | 157 | 0 | 18 |
| 2017 | 7 | 170 | 0 | 32 |
| 2018 | 10 | 200 | 0 | 61 |
| 2019 | 13 | 150 | 0 | 56 |
| 2020 | 5 | 80 | 0 | 24 |
| 2021 | 10 | 126 | 0 | 49 |
| 2022 | 11 | 154 | 0 | 40 |
| 2023 | 5 | 156 | 0 | 50 |
| 2024 | 6 | 254 | 0 | 185 |
| 2025 | 14 | 107 | 1 | 653 |
| 2026 | 10 | 63 | 1 | — |
What is it indicated for?
The use of TrueDorsal® Devices are intended for the reduction of night time snoring and mild to moderate obstructive sleep apnea (OSA) in adults 18 years of age or older.
TrueDorsal® Device is a prescription only device that is customized by True Function Laboratory to dentist specific instructions. It is inserted and removed by the patient and adjusted by the prescribing dentist.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K180691 · printed Nov 4, 2026
Cite this page
510(k) Report. “K180691: TrueDorsal Devices.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K180691
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026