# K180696: Medline Green Ambidextrous Powder-Free Nitrile Examination Gloves with Colloidal Oatmeal (Tested for use with Chemotherapy Drugs)

- Pathway: 510(k) (Traditional)
- Applicant: Medline Industries, Inc.
- Decided: Apr 30, 2018 after 45 days
- Product code: LZA (Polymer Patient Examination Glove)
- Device class: 1
- Regulation: 21 CFR 880.6250
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 2 generations back to K160562 (2016). 2 ancestors in all.
7 later devices descend from it; 1 cites it directly.
0 of 10 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K162982: Medline Nitrile Powder-Free Examination Glove with Colloidal Oatmeal USP (Tested for Use with Chemotherapy Drugs), Medline Industries, Inc. (2017) Summary page 4.

## Most influential descendants
- K192315: Medline Green Ambidextrous Power-Free Nitrile Examination Gloves with Colloidal Oatmeal USP (Tested for Use with Chemotherapy Drugs) (2020), 6 descendants of its own
- K211220: Nitrile Patient Examination Gloves Blue Tested For Use With Chemotherapy Drugs, Nitrile Patient Examination Gloves Blue Violet Tested For Use With Chemotherapy Drugs (2021), 5 descendants of its own
- K213040: Nitrile Patient Examination Gloves Blue Tested For Use With Chemotherapy Drugs,  Nitrile Patient Examination Gloves Blue Violet Tested For Use With Chemotherapy Drugs,Nitrile Patient Examination Gloves Black Tested For Use With Chemotherapy Drugs (2022), 3 descendants of its own
- K261793: Powder-free Nitrile Examination Gloves Tested for Use With Chemotherapy Drugs and Fentanyl Citrate (Blue and Black Color) (2026), 0 descendants of its own
- K221747: Nitrile Patient Examination Gloves Tested For Use With Chemotherapy Drugs (2022), 0 descendants of its own

## Indications for use
A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner’s hand to prevent contamination between patient and examiner. These gloves were tested for use with chemotherapy drugs as per ASTM D6978-05 (Reapproved 2013) Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs. Carmustine (BCNU) 3.3 mg/ml 13.2 minutes Cisplatin 1.0 mg/ml >240 minutes Cyclophosphamide (Cytoxan) 20.0 mg/ml >240 minutes Dacarbazine (DTIC)10.0 mg/ml >240 minutes Doxorubicin Hydrochloride 2.0 mg/ml >240 minutes Etoposide (Toposar) 20.0 mg/ml >240 minutes Fluorouracil 50.0 mg/ml >240 minutes Methotrexate 25.0 mg/ml >240 minutes Mitomycin C 0.5 mg/ml >240 minutes Paclitaxel (Taxol) 6.0 mg/ml >240 minutes Thiotepa 10.0 mg/ml 44.0 minutes Vincristine Sulfate 1.0 mg/ml >240 minutes Please note that the following drug has extremely low permeation times: Carmustine (BCNU) (3.3 mg/ml) 13.2 minutes Please note that the following drug has low permeation times: Thiotepa (10.0 mg/ml) 44.0 minutes