510(k) Report

510(k) · Cleared

Cleared

Atellica IM BRAHMS Procalcitonin (PCT)

K181002510(k) TraditionalCleared Jul 16, 201891-day reviewClass II21 CFR 866.3215

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics, Inc. · PMT Device To Detect And Measure Procalcitonin (Pct) In Human Clinical Specimens

Cleared on Jul 16, 2018 as substantially equivalent to DEN150009 (Brahms GmbH, 2016) and 1 other predicate after a 91-day review. Its family tree reaches back 4 generations to 2007.

Decided
Jul 16, 2018
Review
91 days
Class
Class II
Product code
PMT
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K071146 (2007). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK071146 Vidas B.R.a.H.M.S. PCT AssaybioMerieux, Inc. · 2007 · Recalled
  2. 3 generations backK160911 Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc. · 2016
  3. 2 generations backK162827 Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc. · 2017
  4. 1 generation backK171338 B R A H M S PCT sensitive KRYPTORBrahms GmbH · 2017
  5. This deviceK181002 Atellica IM BRAHMS Procalcitonin (PCT)Siemens Healthcare Diagnostics, Inc. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K071146Vidas B.R.a.H.M.S. PCT AssaybioMerieux, Inc.20071
−3K160911Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc.2016—
−2K162827Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc.2017—
−1K171338B R A H M S PCT sensitive KRYPTORBrahms GmbH2017—
0 (this device)K181002Atellica IM BRAHMS Procalcitonin (PCT)Siemens Healthcare Diagnostics, Inc.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K181002, 2007–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PMT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PMT device

  1. #1 K200236 VITROS BRAHMS PCT Reagent Pack and Calibratorsscore -0.2 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN150009B.R.A.H.M.S PCT sensitive KRYPTOR
Summary page 5
…JIT Regulation Number 21 CFR 862.1150 7. Predicate Devices: Device Name: B.R.A.H.M.S PCT sensitive KRYPTOR 510(k) Number: DEN150009; k171338 Manufacturer: B.R.A.H.M.S GmbH (Thermo Fisher Scientific) 8. Intended Use: Same as Indications for Use 9. Indica…
Brahms GmbH2016—
*K171338B R A H M S PCT sensitive KRYPTOR
Summary page 5
…JIT Regulation Number 21 CFR 862.1150 7. Predicate Devices: Device Name: B.R.A.H.M.S PCT sensitive KRYPTOR 510(k) Number: DEN150009; k171338 Manufacturer: B.R.A.H.M.S GmbH (Thermo Fisher Scientific) 8. Intended Use: Same as Indications for Use 9. Indications for…
Brahms GmbH2017—

Also cleared against DEN150009: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 1.1 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 4 other devices also cite its predicate DEN150009.

How does its category compare?

All PMT devices

PMT Device To Detect And Measure Procalcitonin (Pct) In Human Clinical Specimens: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · PMT

1in 2020

2016: 32018: 12020: 1
2007high 3 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PMT

Too few PMT 510(k)s in any year since 2007 to give a median.

Recalls per year · PMT

No recall names PMT since 2007.

Adverse event reports per year · PMT

1in 2025

2017: 42018: 32019: 12020: 12023: 22024: 12025: 1
2007high 4 (2017) · low 0 (2007)2025

MAUDE reports naming product code PMT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20163—00
20170—04
20181—03
20190—01
20201—01
20210—00
20220—00
20230—02
20240—01
20250—01
20260—0—

What is it indicated for?

The Atellica® IM BRAHMS Procalcitonin (PCT) assay is for in vitro diagnostic use in the quantitative determination of procalcitonin in human serum and plasma (EDTA, lithium heparin, and sodium heparin) using the Atellica® IM Analyzer. The Atellica IM BRAHMS PCT assay is intended for use, in conjunction with other laboratory findings and clinical assessments, as an aid in: • The risk assessment of critically ill patients on their first day of ICU…

Read the full statement (179 words)

The Atellica® IM BRAHMS Procalcitonin (PCT) assay is for in vitro diagnostic use in the quantitative determination of procalcitonin in human serum and plasma (EDTA, lithium heparin, and sodium heparin) using the Atellica® IM Analyzer.

The Atellica IM BRAHMS PCT assay is intended for use, in conjunction with other laboratory findings and clinical assessments, as an aid in:

• The risk assessment of critically ill patients on their first day of ICU admission for progression to severe sepsis and septic shock.

• Assessing the cumulative 28-day risk of all-cause mortality for patients diagnosed with severe sepsis or septic shock in the ICU or when obtained in the emergency department or other medical wards prior to ICU admission, using percent change in PCT level over time.

• Decision-making on antibiotic therapy for patients with suspected or confirmed lower respiratory tract infections (LRTI) – defined as community-acquired pneumonia (CAP), acute bronchitis, and acute exacerbation of chronic obstructive pulmonary disease (AECOPD) – in an inpatient setting or an emergency department.

• Decision-making on antibiotic discontinuation for patients with suspected or confirmed sepsis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K181002: Atellica IM BRAHMS Procalcitonin (PCT).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181002

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026