510(k) Report

510(k) · Cleared

Cleared

Powder Free Blue Nitrile Examination Gloves, Tested for Use with Chemotherapy Drugs

K181130510(k) TraditionalCleared Aug 10, 2018102-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hebei Titans Hongsen Medical Technology Co., Ltd. · LZC Medical Glove, Specialty

Cleared on Aug 10, 2018 as substantially equivalent to K163146 (Hebei Hongsen Plastics Technology Co, Ltd., 2017) after a 102-day review. Its family tree reaches back 4 generations to 2004.

Decided
Aug 10, 2018
Review
102 days
Class
Class I
Product code
LZC
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K042805 (2004). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK042805 Powder Free Nitrile Patient Examination Gloves, Blue Colored…Perusahaan Getah Asas Sdn. Bhd. · 2004
  2. 3 generations backK081089 Kimberly-Clark Sterling Nitrile & Nitrile-Xtra Powder-Free Exam…Kimberly-Clark Corp. · 2008
  3. 2 generations backK141982 Dermagrip Powder Free Blue Nitrile Patient Examination Gloves…Wrp Asia Pacific Sdn. Bhd. · 2015
  4. 1 generation backK163146 POWDER FREE Blue Nitrile GLOVES, Tested for Use with Chemotherapy…Hebei Hongsen Plastics Technology Co, Ltd. · 2017
  5. This deviceK181130 Powder Free Blue Nitrile Examination Gloves, Tested for Use with…Hebei Titans Hongsen Medical Technology Co., Ltd. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K042805Powder Free Nitrile Patient Examination Gloves, Blue Colored Non-SterilePerusahaan Getah Asas Sdn. Bhd.2004—
−3K081089Kimberly-Clark Sterling Nitrile & Nitrile-Xtra Powder-Free Exam Gloves with…Kimberly-Clark Corp.2008—
−2K141982Dermagrip Powder Free Blue Nitrile Patient Examination Gloves, Non-Sterile…Wrp Asia Pacific Sdn. Bhd.2015—
−1K163146POWDER FREE Blue Nitrile GLOVES, Tested for Use with Chemotherapy DrugsHebei Hongsen Plastics Technology Co, Ltd.2017—
0 (this device)K181130Powder Free Blue Nitrile Examination Gloves, Tested for Use with Chemotherapy…Hebei Titans Hongsen Medical Technology Co., Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
FIG. 1 — Lineage of K181130, 2004–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZC device

  1. #1 K201390 Medline Powder-Free Light Blue Nitrile Exam…score 19.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K163146POWDER FREE Blue Nitrile GLOVES, Tested for Use with Chemotherapy Drugs
Summary page 7
…ollowing drugs have low permeation times: Carmustine (BCNU): 8.5 minutes and Thiotepa: 36.1 minutes 5. Predicate Device Identification 510(k) Number: K163146 Product Name: POWDER FREE Blue Nitrile GLOVES, Tested for Use with Chemotherapy Drugs Manufacturer: HEBEI HONGSEN PLAST…
Hebei Hongsen Plastics Technology Co, Ltd.2017—

Also cleared against K163146: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 5 companies; a new generation was cleared every 3.6 years on median.
  • None of the 5 ancestors has a recall.
  • 1 other device also cites its predicate K163146.

How does its category compare?

All LZC devices

LZC Medical Glove, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · LZC

1in 2025

2007: 12008: 32009: 52010: 52012: 42015: 12016: 32017: 62018: 62019: 72020: 32021: 32022: 72025: 12026 (partial year): 1
2007high 7 (2019) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZC

85in 2022

2008: 166 days median2009: 253 days median2010: 68 days median2012: 149 days median2016: 258 days median2017: 121 days median2018: 105 days median2019: 200 days median2020: 167 days median2021: 94 days median2022: 85 days median
2007high 258 (2016) · low 68 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZC

1in 2021

2008: 12011: 42021: 12026 (partial year): 1
2007high 4 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZC

10in 2025

2009: 12011: 12012: 12013: 12014: 32016: 52017: 72018: 62019: 82020: 12021: 22022: 22023: 12024: 162025: 10
2007high 16 (2024) · low 0 (2007)2025

MAUDE reports naming product code LZC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
2008316610
2009525301
201056800
20110—41
2012414901
20130—01
20140—03
20151—00
2016325805
2017612107
2018610506
2019720008
2020316701
202139412
202278502
20230—01
20240—016
20251—010
20261—1—

What is it indicated for?

The Powder Free Blue Nitrile Examination Gloves, Tested for Use with Chemotherapy Drugs is a disposable device intended for medical purposes that is worn on the examiner’s hands to prevent contamination between patient and examiner. The proposed device was tested for use with Chemotherapy Drugs as per ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs: Chemotherapy Drug Permeation The following chemicals…

Read the full statement (264 words)

The Powder Free Blue Nitrile Examination Gloves, Tested for Use with Chemotherapy Drugs is a disposable device intended for medical purposes that is worn on the examiner’s hands to prevent contamination between patient and examiner.

The proposed device was tested for use with Chemotherapy Drugs as per ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs:

Chemotherapy Drug Permeation

The following chemicals have been tested with proposed device.

Chemotherapy Drug Concentration Breakthrough Detection Time in Minutes

Bleomycin 15 mg/ml (15,000 ppm) >240

Busulfan 6 mg/ml (6,000 ppm) >240

Carboplatin 10 mg/ml (10,000ppm) >240

Carmustine (BCNU) 3.3 mg/ml (3,300ppm) 8.5 (12.7, 13.4, 8.5)

Cisplatin 1.0 mg/ml (1,000ppm) >240

Cyclophosphamide(Cytoxan) 20.0 mg/ml (20,000ppm) >240

Cytarabine 100 mg/ml (100,000ppm) >240

Cytovene 10 mg/ml (10,000ppm) >240

Dacarbazine(DTIC) 10.0 mg/ml (10,000ppm) >240

Daunorubicin 5 mg/ml (5,000ppm) >240

Docetaxel 10.0 mg/ml(10,000ppm) >240

Doxorubicin Hydrochloride 2.0 mg/ml (2,000ppm) >240

Ellence 2 mg/ml (2,000ppm) >240

Etoposide(Toposar) 20.0 mg/ml(20,000ppm) >240

Fludarabine 25 mg/ml(25,000ppm) >240

Fluorouracil 50 mg/ml(50,000ppm) >240

Gemcitabine (Gemzar) 38 mg/ml(38,000ppm) >240

Idarubicin 1 mg/ml (1,000ppm) >240

Ifosfamide 50.0 mg/ml (50,000ppm) >240

Irinotecan 20.0 mg/ml (20,000ppm) >240

Mechlorethamine HCI 1.0 mg/ml (1,000ppm) >240

Melphalan 5 mg/ml (5,000ppm) >240

Methotrexate 25mg/ml (25,000ppm) >240

Mitomycin C 0.5 mg/ml (500 ppm) >240

Mitoxantrone 2.0 mg/ml(2,000ppm) >240

Oxaliplatin 2.0 mg/ml(2,000ppm) >240

Paclitaxel (Taxol) 6.0 mg/ml(6,000ppm) >240

Rituximab 10 mg/ml(10,000ppm) >240

Thiotepa 10.0 mg/ml (10,000ppm) 36.1 (51.2, 36.1, 45.6)

Trisenox 0.1 mg/ml (100ppm) >240

Vincristine Sulfate 1.0 mg/ml (1,000ppm) >240

Vinorelbine 10 mg/ml(10,000ppm) >240

*Please note that the following drugs have low permeation times:

Carmustine (BCNU): 8.5 minutes and Thiotepa: 36.1 minutes

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K181130: Powder Free Blue Nitrile Examination Gloves, Tested for Use with Chemotherapy Drugs.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181130

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026