510(k) Report

510(k) · Cleared

Cleared

MUTARS Proximal Femur Replacement System

K181778510(k) TraditionalCleared Mar 25, 2019265-day reviewClass II21 CFR 888.3353

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Implantcast GmbH · MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Cleared on Mar 25, 2019 as substantially equivalent to K965164 (Howmedica Corp., 1997) and 1 other predicate after a 265-day review. Its family tree reaches back 1 generation to 1997. 3 later devices descend from it.

Decided
Mar 25, 2019
Review
265 days
Class
Class II
Product code
MEH
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K965164 (1997). 2 ancestors in all. 3 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor2026: 1 descendant cleared2024: 1 descendant cleared2020: 1 descendant clearedReference device: K163577 · Ecofit® Hip System · Implantcast GmbH · 2017 · recalledK965164 · Howmedica Modular Replacement System-Proximal Femur · Howmedica Corp. · 19971995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants K965164 · Howmedica Modular Replacement System-Proximal Femur · Howmedica Corp. · 19970
  1. Root · 1 generation backK965164 Howmedica Modular Replacement System-Proximal FemurHowmedica Corp. · 1997
  2. This deviceK181778 MUTARS Proximal Femur Replacement SystemImplantcast GmbH · 2019
  3. Descendant · cites it directly · 2 of its ownK200045 MUTARS Cemented Femoral StemsImplantcast GmbH · 2020
  4. Descendant · cites it directly · 1 of its ownK240391 MUTARS® femoral stem cemented 160 mm and 200 mmImplantcast GmbH · 2024
  5. Descendant · cites it directly · 0 of its ownK260037 implantcast Packaging System UpdateImplantcast GmbH · 2026

Most influential descendants

Showing 3 of 3 · See all
  • K200045MUTARS Cemented Femoral StemsImplantcast GmbH · 2020 · cites it directly2descendants
  • K240391MUTARS® femoral stem cemented 160 mm and 200 mmImplantcast GmbH · 2024 · cites it directly1descendant
  • K260037implantcast Packaging System UpdateImplantcast GmbH · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K965164Howmedica Modular Replacement System-Proximal FemurHowmedica Corp.1997—
0 (this device)K181778MUTARS Proximal Femur Replacement SystemImplantcast GmbH2019—
+1K200045MUTARS Cemented Femoral StemsImplantcast GmbH2020—
+1K240391MUTARS® femoral stem cemented 160 mm and 200 mmImplantcast GmbH2024—
+1K260037implantcast Packaging System UpdateImplantcast GmbH2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202410
202610
FIG. 1 — Lineage of K181778, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MEH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MEH device

  1. #1 K210581 Actis DuoFix Hip Prosthesis- Collarlessscore 23.9 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K965164Howmedica Modular Replacement System-Proximal Femur
Summary page 4
…52.5798 [email protected] March 21, 2019 Proximal Femur Replacement 21 CFR §888.3353 21 CFR §888.3390 II MEH, LZO0, Stryker GMRS Proximal Femoral Replacement System (K965164, K023087) Ecofit Hip System (K163577) K181778 Page 2 of 2 Indications for Use: The MUTARS® Proximal Femur Repl…
Howmedica Corp.1997—
*K023087Global Modular Replacement System (GMRS)
Summary page 4
…[email protected] March 21, 2019 Proximal Femur Replacement 21 CFR §888.3353 21 CFR §888.3390 II MEH, LZO0, Stryker GMRS Proximal Femoral Replacement System (K965164, K023087) Ecofit Hip System (K163577) K181778 Page 2 of 2 Indications for Use: The MUTARS® Proximal Femur Replacement S…
Howmedica Osteonics Corp.20022
†K163577Ecofit® Hip SystemImplantcast GmbH20171

Also cleared against K965164: 3 other devices →

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200045MUTARS Cemented Femoral StemsImplantcast GmbH20202
K240391MUTARS® femoral stem cemented 160 mm and 200 mmImplantcast GmbH20241
K260037implantcast Packaging System UpdateImplantcast GmbH20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K200045 (Implantcast GmbH, 2020) has gone furthest, with 2 descendants of its own.
  • 3 other devices also cite its predicate K965164.

How does its category compare?

All MEH devices

MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · MEH

5in 2025

2007: 22008: 62009: 62010: 52011: 52012: 62013: 12015: 22016: 62017: 32018: 22019: 12020: 32021: 32022: 32023: 22024: 62025: 52026 (partial year): 1
2007high 6 (2008) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MEH

87in 2025

2008: 79 days median2009: 65 days median2010: 226 days median2011: 95 days median2012: 131 days median2016: 163 days median2017: 209 days median2020: 131 days median2021: 83 days median2022: 150 days median2024: 91 days median2025: 87 days median
2007high 226 (2010) · low 65 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MEH

1in 2025

2007: 32008: 802009: 512010: 162011: 42012: 32014: 12015: 12016: 42017: 12018: 32020: 12025: 12026 (partial year): 1
2007high 80 (2008) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MEH

470in 2025

2007: 252008: 2612009: 5392010: 4622011: 4192012: 1,6062013: 1,2952014: 1,1962015: 4902016: 3472017: 3832018: 3372019: 3352020: 3382021: 3722022: 3162023: 3342024: 3542025: 470
2007high 1,606 (2012) · low 25 (2007)2025

MAUDE reports naming product code MEH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—325
200867980261
200966551539
2010522616462
20115954419
2012613131,606
20131—01,295
20140—11,196
20152—1490
201661634347
201732091383
20182—3337
20191—0335
202031311338
20213830372
202231500316
20232—0334
20246910354
20255871470
20261—1—

What is it indicated for?

The MUTARS® Proximal Femur Replacement System is a modular hip replacement system offering various components that can be combined to replace the hip joint and address major bone defects with various options depending upon the size and location of the defects of each patient. The MUTARS® Proximal Femur System is intended to for uncemented use in total hip arthroplasty for the following indications: - Proximal femur replacement in oncology cases where…

Read the full statement (117 words)

The MUTARS® Proximal Femur Replacement System is a modular hip replacement system offering various components that can be combined to replace the hip joint and address major bone defects with various options depending upon the size and location of the defects of each patient.

The MUTARS® Proximal Femur System is intended to for uncemented use in total hip arthroplasty for the following indications:

- Proximal femur replacement in oncology cases where radical resection and replacement of bone is required.

- Limb salvage procedures including surgical intervention for severe trauma, failed previous prosthesis, and/or oncology indications, where radical resection and replacement of the bone is required.

Use of this prosthesis is generally only indicated in skeletally mature patients

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K181778: MUTARS Proximal Femur Replacement System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181778

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026