510(k) Report

510(k) · Cleared

Cleared

Bi-Flex Evo

K182144510(k) SpecialCleared Sep 7, 201830-day reviewClass II21 CFR 876.5130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Promepla Sam · KNY Accessories, Catheter, G-U

Cleared on Sep 7, 2018 as substantially equivalent to K140441 (Promepla Sam, 2014) after a 30-day review. Its family tree reaches back 5 generations to 1996.

Decided
Sep 7, 2018
Review
30 days
Class
Class II
Product code
KNY
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K961904 (1996). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK961904 AQ Hydrophilic DilatorsCook Urological, Inc. · 1996
  2. 4 generations backK981611 Snap-N-Peel IntroducersCircon Corp. · 1998
  3. 3 generations backK051593 Uropass Ureteral Access Sheath, Model 61224Acmi Corporation · 2005 · Recalled
  4. 2 generations backK120160 Rocamed Rocaus PlatinumPromepla Sam · 2012
  5. 1 generation backK140441 BI-Flex Ureteral Access SheathPromepla Sam · 2014
  6. This deviceK182144 Bi-Flex EvoPromepla Sam · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K961904AQ Hydrophilic DilatorsCook Urological, Inc.1996—
−4K981611Snap-N-Peel IntroducersCircon Corp.1998—
−3K051593Uropass Ureteral Access Sheath, Model 61224Acmi Corporation20052
−2K120160Rocamed Rocaus PlatinumPromepla Sam2012—
−1K140441BI-Flex Ureteral Access SheathPromepla Sam2014—
0 (this device)K182144Bi-Flex EvoPromepla Sam2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
199920
200310
FIG. 1 — Lineage of K182144, 1996–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNY device

  1. #1 K260919 Transurethral Catheter Safety Valve (TUCSV)…score 11.8 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140441BI-Flex Ureteral Access Sheath
Summary page 4
…N° Product name Manufacturer 510(k) number 1 Bi-Flex Ureteral Access Sheath PROMEPLA SAM K140441 Section 5 CONFIDENTIAL Page 1 of 2…
Promepla Sam2014—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 4.2 years on median.
  • 1 of the 9 ancestors has a recall of any class.

How does its category compare?

All KNY devices

KNY Accessories, Catheter, G-U: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · KNY

1in 2018

2009: 12011: 12012: 12013: 22014: 32017: 12018: 12026 (partial year): 1
2007high 3 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNY

103in 2014

2014: 103 days median
2007high 103 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNY

1in 2024

2011: 12024: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KNY

3in 2025

2007: 152008: 192009: 102010: 122011: 62012: 52013: 82014: 72015: 132016: 192017: 212018: 172019: 192020: 362021: 172022: 192023: 132024: 52025: 3
2007high 36 (2020) · low 3 (2025)2025

MAUDE reports naming product code KNY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—015
20080—019
20091—010
20100—012
20111—16
20121—05
20132—08
2014310307
20150—013
20160—019
20171—021
20181—017
20190—019
20200—036
20210—017
20220—019
20230—013
20240—15
20250—03
20261—0—

What is it indicated for?

The BiFlex Evo is intended to be a conduit for passage of endoscopes and other urological devices for the purpose of performing ureteroscopy procedures. The dual working lumen dilator with luer lock connections allows the user to insert guidewires and fluids

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K182144: Bi-Flex Evo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K182144

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026