510(k) · Cleared
ClearedA.B. DENTAL DEVICES Dental Implants System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
A.B. Dental Device, Ltd. · NHA Abutment, Implant, Dental, Endosseous
Cleared on Jul 15, 2019 as substantially equivalent to K162482 (A.B. Dental Device, Ltd., 2017) and 2 other predicates after a 311-day review. Its family tree reaches back 16 generations to 1996.
- Decided
- Jul 15, 2019
- Review
- 311 days
- Class
- Class II
- Product code
- NHA
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 16 generations to K960026 (1996). 264 ancestors in all, the oldest K781060 (1978). No later device cites it as a predicate yet.
- Root · 16 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
- 12 generations between
- 3 generations backK112440 AB Dental Devices Implants and AccessoriesA.B. Dental Devices, Ltd. · 2012
- 2 generations backK132125 A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd. · 2014
- 1 generation backK162482 A.B. DENTAL DEVICES Dental Implants SystemA.B. Dental Device, Ltd. · 2017
- This deviceK182455 A.B. DENTAL DEVICES Dental Implants SystemA.B. Dental Device, Ltd. · 2019
Show all 16 generations
- Root · 16 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
- 15 generations backK964330 Biohorizons Dental Implant System (Name Subject to Change)BioHorizons Implant Systems, Inc. · 1997
- 14 generations backK972313 The Maestro SystemBioHorizons Implant Systems, Inc. · 1997
- 13 generations backK020133 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 12 generations backK020645 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 11 generations backK022795 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 10 generations backK030463 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2003 · Recalled
- 9 generations backK032351 The Maestro System 3.0MM Diameter ImplantBioHorizons Implant Systems, Inc. · 2003
- 8 generations backK041938 Maximus OS (Overdenture System)BioHorizons Implant Systems, Inc. · 2004 · Recalled
- 7 generations backK052419 Maximus 3.0 and OS ImplantsBioHorizons Implant Systems, Inc. · 2005
- 6 generations backK093321 Biohorizons Laser-Lok 3.0 Implant SystemBioHorizons Implant Systems, Inc. · 2010 · Recalled
- 5 generations backK100985 Biohorizons Simple Solutions with Laser-LokBioHorizons Implant Systems, Inc. · 2010
- 4 generations backK103691 Biohorizons Abutments for ZimmerBioHorizons Implant Systems, Inc. · 2011 · Recalled
- 3 generations backK112440 AB Dental Devices Implants and AccessoriesA.B. Dental Devices, Ltd. · 2012
- 2 generations backK132125 A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd. · 2014
- 1 generation backK162482 A.B. DENTAL DEVICES Dental Implants SystemA.B. Dental Device, Ltd. · 2017
- This deviceK182455 A.B. DENTAL DEVICES Dental Implants SystemA.B. Dental Device, Ltd. · 2019
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −16 | K960026 | Biohorizons Dental Implant System | BioHorizons Implant Systems, Inc. | 1996 | — |
| −15 | K964330 | Biohorizons Dental Implant System (Name Subject to Change) | BioHorizons Implant Systems, Inc. | 1997 | — |
| −14 | K972313 | The Maestro System | BioHorizons Implant Systems, Inc. | 1997 | — |
| −13 | K020133 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −12 | K020645 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −11 | K022795 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −10 | K030463 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2003 | 1 |
| −9 | K032351 | The Maestro System 3.0MM Diameter Implant | BioHorizons Implant Systems, Inc. | 2003 | — |
| −8 | K041938 | Maximus OS (Overdenture System) | BioHorizons Implant Systems, Inc. | 2004 | 2 |
| −7 | K052419 | Maximus 3.0 and OS Implants | BioHorizons Implant Systems, Inc. | 2005 | — |
| −6 | K093321 | Biohorizons Laser-Lok 3.0 Implant System | BioHorizons Implant Systems, Inc. | 2010 | 1 |
| −5 | K100985 | Biohorizons Simple Solutions with Laser-Lok | BioHorizons Implant Systems, Inc. | 2010 | — |
| −4 | K103691 | Biohorizons Abutments for Zimmer | BioHorizons Implant Systems, Inc. | 2011 | 1 |
| −3 | K112440 | AB Dental Devices Implants and Accessories | A.B. Dental Devices, Ltd. | 2012 | — |
| −2 | K132125 | A.B. Dental Devices Dental Implants System | A.B. Dental Devices, Ltd. | 2014 | — |
| −1 | K162482 | A.B. DENTAL DEVICES Dental Implants System | A.B. Dental Device, Ltd. | 2017 | — |
| 0 (this device) | K182455 | A.B. DENTAL DEVICES Dental Implants System | A.B. Dental Device, Ltd. | 2019 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1982 | 1 | 0 |
| 1984 | 1 | 0 |
| 1985 | 1 | 0 |
| 1986 | 2 | 0 |
| 1987 | 2 | 0 |
| 1988 | 1 | 0 |
| 1989 | 5 | 0 |
| 1990 | 7 | 0 |
| 1991 | 3 | 0 |
| 1992 | 4 | 0 |
| 1993 | 13 | 0 |
| 1994 | 13 | 0 |
| 1995 | 11 | 0 |
| 1996 | 16 | 0 |
| 1997 | 6 | 0 |
| 1998 | 8 | 0 |
| 1999 | 12 | 0 |
| 2000 | 8 | 0 |
| 2001 | 13 | 0 |
| 2002 | 15 | 0 |
| 2003 | 15 | 0 |
| 2004 | 17 | 0 |
| 2005 | 10 | 0 |
| 2006 | 17 | 0 |
| 2007 | 19 | 0 |
| 2008 | 9 | 0 |
| 2009 | 11 | 0 |
| 2010 | 4 | 0 |
| 2011 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NHA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NHA device
- #1 K222288 DESS Dental Smart Solutionsscore 30.6 · 19 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K162482 | A.B. DENTAL DEVICES Dental Implants SystemSummary page 4…tment, implant, dental, endosseous Classification: 21 CFR §872.3630 Endosseous dental implant abutment Product Code: NHA Predicate Devices K162482 A.B. DENTAL DEVICES® Dental Implants System (primary) K131215 A.B. DENTAL DEVICES® Dental Implants System (reference) K112440, DE… | 2017 |
| * | K132125 | A.B. Dental Devices Dental Implants SystemSummary page 8…Predicate P4S-3.75,15- Predicate P4L-3.75,25 (1,2,3) (1, 3) 510(k) Subject K132125 K162482 Number Material Ti-6Al-4V ELI Ti-6Al-4V ELI Ti-6Al-4… | 2014 |
| * | K111357 | Straumann Narrow Neck Crossfit (NNC) 03.3MM Dental Implant SystemSummary page 4…TAL DEVICES® Dental Implants System (primary) K131215 A.B. DENTAL DEVICES® Dental Implants System (reference) K112440, DENTAL DEVICES® Dental Implants System (reference) K111357 Straumann Crossfit SLA 3.3 mm (reference) Device Description A.B. DENTAL DEVICES® Dental Implants System consists of narrow (XXX… | 2011 |
| † | K112440 | AB Dental Devices Implants and Accessories | 2012 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 23 years and passes through 3 companies; a new generation was cleared every 10 months on median.
- 35 of the 264 ancestors have a recall of any class.
- 2 other devices also cite its predicate K162482.
How does its category compare?
All NHA devicesNHA Abutment, Implant, Dental, Endosseous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · NHA
40in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NHA
147in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NHA
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · NHA
838in 2025
MAUDE reports naming product code NHA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 38 | 91 | 1 | 1 |
| 2008 | 31 | 90 | 2 | 8 |
| 2009 | 30 | 95 | 0 | 30 |
| 2010 | 19 | 162 | 0 | 61 |
| 2011 | 31 | 130 | 5 | 56 |
| 2012 | 25 | 171 | 1 | 5 |
| 2013 | 22 | 184 | 1 | 143 |
| 2014 | 27 | 160 | 0 | 146 |
| 2015 | 29 | 151 | 1 | 858 |
| 2016 | 38 | 202 | 36 | 314 |
| 2017 | 31 | 188 | 2 | 577 |
| 2018 | 31 | 200 | 1 | 591 |
| 2019 | 28 | 160 | 0 | 530 |
| 2020 | 38 | 153 | 7 | 458 |
| 2021 | 29 | 211 | 0 | 546 |
| 2022 | 33 | 142 | 0 | 497 |
| 2023 | 51 | 147 | 3 | 618 |
| 2024 | 43 | 158 | 0 | 635 |
| 2025 | 40 | 147 | 1 | 838 |
| 2026 | 23 | 169 | 3 | — |
What is it indicated for?
A.B. DENTAL DEVICES® Dental Implants System is indicated for use in surgical and restorative applications for placement in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, in order to restore the patient's chewing function. A.B. DENTAL DEVICES® Dental Implants System is indicated also for immediate loading when good primary stability is achieved and with appropriate occlusal loading.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K182455 · printed Nov 6, 2026
Cite this page
510(k) Report. “K182455: A.B. DENTAL DEVICES Dental Implants System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K182455
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026