510(k) Report

510(k) · Cleared

Cleared

DeepCT

K182875510(k) TraditionalCleared Jul 10, 2019271-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Deep01 Limited · QAS Radiological Computer-Assisted Triage And Notification Software

Cleared on Jul 10, 2019 as substantially equivalent to DEN170073 (Viz.Al, Inc., 2018) and 1 other predicate after a 271-day review. Its family tree reaches back 2 generations to 2018.

Decided
Jul 10, 2019
Review
271 days
Class
Class II
Product code
QAS
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to DEN170073 (2018). No later device cites it as a predicate yet.

DEN170073 · ContaCT · Viz.Al, Inc. · 2018K180647 · BriefCase · Aidoc Medical, Ltd. · 2018201620182020
  1. Root · 2 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 1 generation backK180647 BriefCaseAidoc Medical, Ltd. · 2018
  3. This deviceK182875 DeepCTDeep01 Limited · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2DEN170073ContaCTViz.Al, Inc.2018—
−1K180647BriefCaseAidoc Medical, Ltd.2018—
0 (this device)K182875DeepCTDeep01 Limited2019—
FIG. 1 — Lineage of K182875, 2018–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAS device

  1. #1 K203508 BriefCasescore 25.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN170073ContaCT
Summary page 5
…logical Computer-Assisted Triage And Notification Software (21 CFR 892.2080) Regulatory Class: II Product Code: QAS III. PREDICATE DEVICE DEN170073, ContaCT K180647, BriefCase IV. DEVICE DESCRIPTION This software is used to analyze the head computed tomography…
Viz.Al, Inc.2018—
*K180647BriefCase
Summary page 5
…riage And Notification Software (21 CFR 892.2080) Regulatory Class: II Product Code: QAS III. PREDICATE DEVICE DEN170073, ContaCT K180647, BriefCase IV. DEVICE DESCRIPTION This software is used to analyze the head computed tomography image of a patien…
Aidoc Medical, Ltd.2018—

Also cleared against DEN170073: 9 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 1 year and passes through 3 companies; a new generation was cleared every 11 months on median.
  • None of the 2 ancestors has a recall.
  • 9 other devices also cite its predicate DEN170073.

How does its category compare?

All QAS devices

QAS Radiological Computer-Assisted Triage And Notification Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · QAS

15in 2025

2018: 32019: 52020: 122021: 52022: 152023: 112024: 122025: 152026 (partial year): 11
2007high 15 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAS

101in 2025

2019: 111 days median2020: 112 days median2021: 86 days median2022: 116 days median2023: 98 days median2024: 136 days median2025: 101 days median2026 (partial year): 104 days median
2007high 136 (2024) · low 86 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QAS

No recall names QAS since 2007.

Adverse event reports per year · QAS

No MAUDE report names QAS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20183—00
2019511100
20201211200
202158600
20221511600
2023119800
20241213600
20251510100
2026111040—

What is it indicated for?

DeepCT is a notification-only, parallel workflow tool for use by hospital networks and trained clinicians to identify and communicate images of specific patients to a specialist, independent of standard of care workflow. DeepCT uses an artificial intelligence algorithm to analyze images for findings suggestive of a pre-specified clinical condition and to notify an appropriate medical specialist of these findings in parallel to standard of care image…

Read the full statement (175 words)

DeepCT is a notification-only, parallel workflow tool for use by hospital networks and trained clinicians to identify and communicate images of specific patients to a specialist, independent of standard of care workflow.

DeepCT uses an artificial intelligence algorithm to analyze images for findings suggestive of a pre-specified clinical condition and to notify an appropriate medical specialist of these findings in parallel to standard of care image interpretation. Identification of suspected findings is not for diagnostic use beyond notification. Specifically, the device analyzes non-contrast CT images of the brain acquired in the acute setting and sends notifications to a specialist that a suspected ICH (intracranial hemorrhage) has been identified and recommends review of those images.

Notified clinicians are responsible for viewing non-contrast CT images of the brain on a diagnostic viewer and engaging in appropriate patient evaluation and relevant discussion with a treating specialist before making care-related decisions or requests. DeepCT is limited to analysis of imaging data and should not be used in-lieu of full patient evaluation or relied upon to make or confirm diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K182875: DeepCT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K182875

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026