# K183071: VLIFT-s Vertebral Body Replacement System

- Pathway: 510(k) (Special)
- Applicant: Stryker Spine
- Decided: Jan 10, 2019 after 66 days
- Product code: PLR (Spinal Vertebral Body Replacement Device - Cervical)
- Device class: 2
- Regulation: 21 CFR 888.3060
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 17 generations back to K003155 (2001). 86 ancestors in all.
4 later devices descend from it; 2 cite it directly.
0 of 91 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K172032: Modulift Vertebral Body Replacement (VBR) System, Aesculap Implants Systems, Inc. (2017) Summary page 4.
- K180673: Normandy VBR System, Zavation Medical Products, LLC (2018) Summary page 4.
- K162315: FORTIFY Corpectomy Spacers, Globus Medical, Inc. (2017) Summary page 4.
- K152568: C-VBR, Cardinal Spine, LLC (2016) Summary page 4.
- K151651: NuVasive X-CORE Mini Cervical Expandable VBR System, Nu Vasive, Incorporated (2015) Summary page 4.
- K091946: Vlift-S Vertebral Body Replacement System, Models 488812XX, 488814XX, 488816XX, 488818XX, Stryker Spine (2009) Summary page 4.
- K060416: Obelisc Vertebral Body Replacement Device, Ulrich GmbH & Co. KG (2006) Summary page 4.

## Most influential descendants
- K241468: Vertiwedge® Intraosseous System (2024), 1 descendant of its own
- K221490: Tritanium C Anterior Cervical Cage, Tritanium PL Cage, Tritanium TL Curved Posterior Lumbar Cage, Tritanium X PL Expandable Posterior Lumbar Cage, Tritanium X TL Expandable Curved Posterior Lumbar Cage, Stryker Spine VLIFT Vertebral Body Replacement System, VLIFT-s Vertebral Body Replacement System, Ascential IBD PEEKc Spacer, Aero-AL Lumbar Cage System, Aero-LL Lumbar Cage System, Aero-C Cervical Cage System, AVS Aria PEEK Spacer, AVS Anchor-C Cervical Cage System, AVS Anchor-L Spacer (2023), 1 descendant of its own
- K261810: Vertiwedge® Intraosseous System (2026), 0 descendants of its own
- K262061: Tritanium® C Anterior Cervical Cage; Tritanium® PL Cage; Tritanium® TL Curved Posterior Lumbar Cage; Aero® -C Cervical Cage System; AVS® Anchor-C Cervical Cage System; AVS® TL PEEK Spacer; AVS® PL PEEK Spacers; AVS® Navigator PEEK Spacer; AVS® AS PEEK Spacer; Monterey™ AL Interbody System; Aleutian IBF System; Cascadia Interbody System; Chesapeake Stabilization System; Sahara Stabilization System; SANTORINI™ Corpectomy Cage System; MOJAVE Interbody System; VLIFT VERTEBRAL BODY REPLACEM (2026), 0 descendants of its own

## Indications for use
VLIFT®-s Vertebral Body Replacement System is indicated for use in the cervical spine (C3-C7) and the thoracolumbar spine (T1-L5) in skeletally mature patients for partial or total replacement of a diseased, collapsed, damaged, or unstable vertebral body due to tumor, osteomyelitis, trauma (i.e., fracture), or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissue in degenerative disorders. The VLIFT®-s Vertebral Body Replacement System is intended for use with autograft or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft, as an adjunct to fusion. The VLIFT®-s Vertebral Body Replacement System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical, thoracic, and lumbar spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon's discretion. The VLIFT®-s Vertebral Body Replacement System is intended to be used with FDA-cleared supplemental spinal fixation systems that have been labeled for use in the cervical, thoracic, and/or lumbar spine (i.e., posterior screw and rod systems, anterior plate systems, and anterior screw and rod systems). When used at more than two levels, supplemental fixation should include posterior fixation.

Source page: https://510kreport.com/device/K183071
Methodology: https://510kreport.com/methodology
