510(k) Report

510(k) · Cleared

Cleared

BriefCase

K190072510(k) TraditionalCleared Apr 15, 201990-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aidoc Medical, Ltd. · QAS Radiological Computer-Assisted Triage And Notification Software

Cleared on Apr 15, 2019 as substantially equivalent to K180647 (Aidoc Medical, Ltd., 2018) after a 90-day review. Its family tree reaches back 2 generations to 2018. 30 later devices descend from it.

Decided
Apr 15, 2019
Review
90 days
Class
Class II
Product code
QAS
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to DEN170073 (2018). 30 later devices descend from it, 5 citing it directly.

Descendants, by year cleared 2022: 9 descendants cleared2021: 2 descendants cleared2020: 2 descendants cleared2023: 3 descendants cleared2024: 6 descendants cleared2026: 5 descendants cleared2025: 3 descendants clearedDEN170073 · ContaCT · Viz.Al, Inc. · 2018K180647 · BriefCase · Aidoc Medical, Ltd. · 2018201620182020202220242026
Descendants, by generation 1 generation forward: 5 descendants2 generations forward: 11 descendants3 generations forward: 12 descendants4 generations forward: 2 descendants K180647 · BriefCase · Aidoc Medical, Ltd. · 2018DEN170073 · ContaCT · Viz.Al, Inc. · 20180
  1. Root · 2 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 1 generation backK180647 BriefCaseAidoc Medical, Ltd. · 2018
  3. This deviceK190072 BriefCaseAidoc Medical, Ltd. · 2019
  4. Descendant · cites it directly · 18 of its ownK201020 BriefCaseAidoc Medical, Ltd. · 2020
  5. Descendant · cites it directly · 17 of its ownK203508 BriefCaseAidoc Medical, Ltd. · 2020
  6. Descendant · cites it directly · 5 of its ownK210237 Cina ChestAvicenna.Ai · 2021
  7. Descendant · 2 generations on · 4 of its ownK222329 BriefCaseAidoc Medical, Ltd. · 2022
  8. Descendant · 3 generations on · 2 of its ownK251406 BriefCase-TriageAidoc Medical, Ltd. · 2025

Showing 5 of 30 descendants. See all descendants

Descendants cleared per year

2020: 22021: 22022: 92023: 32024: 62025: 32026: 5
2020high 9 (2022) · low 2 (2020)2026

Most influential descendants

Showing 5 of 30 · See all
  • K201020BriefCaseAidoc Medical, Ltd. · 2020 · cites it directly18descendants
  • K203508BriefCaseAidoc Medical, Ltd. · 2020 · cites it directly17descendants
  • K210237Cina ChestAvicenna.Ai · 2021 · cites it directly5descendants
  • K222329BriefCaseAidoc Medical, Ltd. · 2022 · 2 generations on4descendants
  • K251406BriefCase-TriageAidoc Medical, Ltd. · 2025 · 3 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2DEN170073ContaCTViz.Al, Inc.2018—
−1K180647BriefCaseAidoc Medical, Ltd.2018—
0 (this device)K190072BriefCaseAidoc Medical, Ltd.2019—
+1K201020BriefCaseAidoc Medical, Ltd.2020—
+1K203508BriefCaseAidoc Medical, Ltd.2020—
+1K210237Cina ChestAvicenna.Ai2021—
+2K222329BriefCaseAidoc Medical, Ltd.2022—
+3K251406BriefCase-TriageAidoc Medical, Ltd.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202020
202120
202290
202330
202460
202530
202650
FIG. 1 — Lineage of K190072, 2018–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAS device

  1. #1 K203508 BriefCasescore 25.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180647BriefCase
Summary page 4
…device Regulatory Class: Class II Product Code: QAS (21 C.F.R. 892.2080) Predicate Device: BriefCase (K180647, for ICH triage) Device Description BriefCase is a radiological computer-assisted triage and notification software device. The…
Aidoc Medical, Ltd.2018—

Also cleared against K180647: 11 other devices →

What descends from it? (30)

See all 30

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K201020BriefCaseAidoc Medical, Ltd.202018
K203508BriefCaseAidoc Medical, Ltd.202017
K210237Cina ChestAvicenna.Ai20215
K202992BriefCase, RIB Fractures Triage (RibFx)Aidoc Medical, Ltd.20212
K220499Rapid PE Triage and Notification (PETN)Ischemaview, Inc.20221

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 1 year and passes through 2 companies; a new generation was cleared every 8 months on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K201020 (Aidoc Medical, Ltd., 2020) has gone furthest, with 18 descendants of its own.
  • 11 other devices also cite its predicate K180647.

How does its category compare?

All QAS devices

QAS Radiological Computer-Assisted Triage And Notification Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · QAS

15in 2025

2018: 32019: 52020: 122021: 52022: 152023: 112024: 122025: 152026 (partial year): 11
2007high 15 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAS

101in 2025

2019: 111 days median2020: 112 days median2021: 86 days median2022: 116 days median2023: 98 days median2024: 136 days median2025: 101 days median2026 (partial year): 104 days median
2007high 136 (2024) · low 86 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QAS

No recall names QAS since 2007.

Adverse event reports per year · QAS

No MAUDE report names QAS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20183—00
2019511100
20201211200
202158600
20221511600
2023119800
20241213600
20251510100
2026111040—

What is it indicated for?

BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of non-enhanced head CT and CTPA images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of Intracranial Hemorrhage (ICH) and Pulmonary Embolism (PE) pathologies. For the PE pathology, the software is only intended to be used on…

Read the full statement (191 words)

BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of non-enhanced head CT and CTPA images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of Intracranial Hemorrhage (ICH) and Pulmonary Embolism (PE) pathologies. For the PE pathology, the software is only intended to be used on single-energy exams.

BriefCase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a standalone desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device.

The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190072: BriefCase.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K190072

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026