510(k) Report

510(k) · Cleared

Recalled · Class II · 2025

Xpert BCR-ABL Ultra, GeneXpert Dx System, GeneXpert Infinity-48s and GeneXpert Infinity-80 Systems

K190076510(k) TraditionalCleared Sep 27, 2019254-day reviewClass II21 CFR 866.6060Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cepheid · OYX Bcr/Abl1 Monitoring Test

Cleared on Sep 27, 2019 as substantially equivalent to DEN160003 (Asuragen, Inc., 2016) after a 254-day review. Its family tree reaches back 1 generation to 2016. It has been recalled once.

Decided
Sep 27, 2019
Review
254 days
Class
Class II
Product code
OYX
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to DEN160003 (2016). No later device cites it as a predicate yet.

DEN160003 · Quantidex qPCR BCR-ABL IS Kit · Asuragen, Inc. · 2016201620182020
DEN160003 · Quantidex qPCR BCR-ABL IS Kit · Asuragen, Inc. · 20160
  1. Root · 1 generation backDEN160003 Quantidex qPCR BCR-ABL IS KitAsuragen, Inc. · 2016
  2. This deviceK190076 Xpert BCR-ABL Ultra, GeneXpert Dx System, GeneXpert Infinity-48s and…Cepheid · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1DEN160003Quantidex qPCR BCR-ABL IS KitAsuragen, Inc.2016—
0 (this device)K190076Xpert BCR-ABL Ultra, GeneXpert Dx System, GeneXpert Infinity-48s and GeneXpert…Cepheid2019—
FIG. 1 — Lineage of K190076, 2016–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OYX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OYX device

  1. #1 K252243 Fastplex™ BCR-ABL (p210) %IS digital PCR Kitscore 12.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN160003Quantidex qPCR BCR-ABL IS Kit
Summary page 4
…Pathology (88) Advisory Panel Prescription Use Yes Predicate Device Asuragen QuantideX qPCR BCR-ABL IS Kit [DEN160003] Xpert BCR-ABL Ultra 510(k) Page 1 Device Intended Use: The X…
Asuragen, Inc.2016—

Also cleared against DEN160003: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 30, 2025Class IIZ-0959-2026Process designInvitro diagnostic test kits with specimens that have elevated white blood cell count (>30,000 cell) may cause inaccurate results.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate DEN160003.

How does its category compare?

All OYX devices

OYX Bcr/Abl1 Monitoring Test: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · OYX

1in 2023

2016: 12017: 12019: 22023: 12026 (partial year): 1
2007high 2 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OYX

Too few OYX 510(k)s in any year since 2007 to give a median.

Recalls per year · OYX

2in 2025

2025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OYX

4in 2025

2024: 12025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code OYX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—00
20171—00
20180—00
20192—00
20200—00
20210—00
20220—00
20231—00
20240—01
20250—24
20261—0—

What is it indicated for?

The Xpert BCR-ABL Ultra test is an in vitro diagnostic test for the quantitation of BCR-ABL1 and ABL1 mRNA transcripts in peripheral blood specimens of diagnosed t(9;22) positive Chronic Myeloid Leukemia (CML) patients expressing BCR-ABLl fusion transcripts type e13a2 and/or e14a2. The test utilizes automated, quantitative, real-time reverse transcription polymerase chain reaction (RT-qPCR). The Xpert BCR-ABL Ultra test is intended to measure BCR-ABL1 to…

Read the full statement (155 words)

The Xpert BCR-ABL Ultra test is an in vitro diagnostic test for the quantitation of BCR-ABL1 and ABL1 mRNA transcripts in peripheral blood specimens of diagnosed t(9;22) positive Chronic Myeloid Leukemia (CML) patients expressing BCR-ABLl fusion transcripts type e13a2 and/or e14a2. The test utilizes automated, quantitative, real-time reverse transcription polymerase chain reaction (RT-qPCR). The Xpert BCR-ABL Ultra test is intended to measure BCR-ABL1 to ABL1 percent ratios on the International Scale (IS), and also expressed as a log molecular reduction (MR value) from a baseline of 100% (IS), in t(9;22) positive CML patients during monitoring of treatment with Tyrosine Kinase Inhibitors (TKIs).

The test does not differentiate between e13a2/b2a2 or e14a2/b3a2 fusion transcripts and does not monitor other rare fusion transcripts resulting from t(9;22). This test is not intended for the diagnosis of CML.

The Xpert BCR-ABL Ultra test is intended for use only on the Cepheid GeneXpert® Dx System and the GeneXpert Infinity System.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190076: Xpert BCR-ABL Ultra, GeneXpert Dx System, GeneXpert Infinity-48s and GeneXpert Infinity-80 Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K190076

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026