510(k) Report

510(k) · Cleared

Cleared

TDM Screw Systems

K190830510(k) TraditionalCleared Sep 13, 2019165-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Tdm Co., Ltd. · HWC Screw, Fixation, Bone

Cleared on Sep 13, 2019 as substantially equivalent to K161616 (Synthes USA Products, LLC, 2017) and 5 other predicates after a 165-day review. Its family tree reaches back 12 generations to 1996. 1 later device descends from it.

Decided
Sep 13, 2019
Review
165 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
6

Its longest line of descent runs back 12 generations to K962616 (1996). 141 ancestors in all, the oldest K792022 (1979). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2008: 4 other ancestors2006: 9 other ancestors2005: 7 other ancestors2002: 8 other ancestors2012: 1 other ancestor2011: 2 other ancestors2010: 3 other ancestors2009: 3 other ancestors2001: 11 other ancestors1998: 7 other ancestors1996: 14 other ancestors2007: 4 other ancestors2003: 6 other ancestors2000: 10 other ancestors1999: 6 other ancestors1995: 7 other ancestors1994: 7 other ancestors1993: 2 other ancestors1992: 3 other ancestors1990: 1 other ancestor1989: 3 other ancestors1981: 1 other ancestor1979: 2 other ancestors2004: 5 other ancestors1991: 1 other ancestor1997: 1 other ancestor2024: 1 descendant clearedK962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 1996K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 1998×3: 3 generations cleared close together, K023007 (2002), K030198 (2003), K032705 (2003) ×2: 2 generations cleared close together, K050932 (2005), K051735 (2005) K071563 · Peri-Loc Periarticular Locked Plating System · Smith & Nephew, Inc. · 2007K090675 · Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accessories · Smith & Nephew, Inc. · 2009K100776 · Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot System · Synthes (Usa) · 2010K112583 · Synthes Cortical Screws · Synthes (USA) Products, LLC · 2011K161616 · DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm Cannulated Screws, DePuy Synthes 3.5 mm and 4.0 mm Cannulated Screws, DePuy Synthes 4.5 mm Cannulated Screws, DePuy Synthes 6.5 mm Cannulated Screws, DePuy Synthes 7.0 mm and 7.3 mm Cannulated Screws, DePuy Synthes 1.5 mm Headless Compression Screws, DePuy Synthes 2.4 mm Headless Compression Screws, DePuy Synthes 3.0 mm Headless Compression Screws, DePuy Synthes 4.5 mm and 6.5 mm Headless Compression Screw · Synthes USA Products, LLC · 201719801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 5 other ancestors2 generations back: 12 other ancestors3 generations back: 22 other ancestors4 generations back: 26 other ancestors5 generations back: 17 other ancestors6 generations back: 13 other ancestors7 generations back: 15 other ancestors8 generations back: 12 other ancestors9 generations back: 4 other ancestors10 generations back: 1 other ancestor11 generations back: 1 other ancestor12 generations back: 1 other ancestor 1 generation forward: 1 descendant K161616 · DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm Cannulated Screws, DePuy Synthes 3.5 mm and 4.0 mm Cannulated Screws, DePuy Synthes 4.5 mm Cannulated Screws, DePuy Synthes 6.5 mm Cannulated Screws, DePuy Synthes 7.0 mm and 7.3 mm Cannulated Screws, DePuy Synthes 1.5 mm Headless Compression Screws, DePuy Synthes 2.4 mm Headless Compression Screws, DePuy Synthes 3.0 mm Headless Compression Screws, DePuy Synthes 4.5 mm and 6.5 mm Headless Compression Screw · Synthes USA Products, LLC · 2017K112583 · Synthes Cortical Screws · Synthes (USA) Products, LLC · 2011K100776 · Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot System · Synthes (Usa) · 2010K090675 · Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accessories · Smith & Nephew, Inc. · 2009K071563 · Peri-Loc Periarticular Locked Plating System · Smith & Nephew, Inc. · 2007K051735 · Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper Extremity · Smith & Nephew, Inc. · 2005K050932 · Distal Volar Radius Anatomical Plate System · Hand Innovations, Inc. · 2005 · recalledK032705 · Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2003K030198 · Hand Innovations, Inc. Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2003K023007 · Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2002K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 1998K962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 1996−10−50
  1. Root · 12 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 8 generations between
  3. 3 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
  4. 2 generations backK112583 Synthes Cortical ScrewsSynthes (USA) Products, LLC · 2011
  5. 1 generation backK161616 DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm…Synthes USA Products, LLC · 2017
  6. This deviceK190830 TDM Screw SystemsTdm Co., Ltd. · 2019
  7. Descendant · cites it directly · 0 of its ownK231860 TDM Screw SystemTdm Co., Ltd. · 2024
Show all 12 generations
  1. Root · 12 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 11 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
  3. 10 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
  4. 9 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  5. 8 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  6. 7 generations backK050932 Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc. · 2005 · Recalled
  7. 6 generations backK051735 Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper…Smith & Nephew, Inc. · 2005
  8. 5 generations backK071563 Peri-Loc Periarticular Locked Plating SystemSmith & Nephew, Inc. · 2007
  9. 4 generations backK090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and AccessoriesSmith & Nephew, Inc. · 2009
  10. 3 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
  11. 2 generations backK112583 Synthes Cortical ScrewsSynthes (USA) Products, LLC · 2011
  12. 1 generation backK161616 DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm…Synthes USA Products, LLC · 2017
  13. This deviceK190830 TDM Screw SystemsTdm Co., Ltd. · 2019

Most influential descendants

Showing 1 of 1 · See all
  • K231860TDM Screw SystemTdm Co., Ltd. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K962616Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa)1996—
−11K982732Synthes (Usa) Distal Radius Plate System (DRPS)Synthes1998—
−10K023007Distal Radius Fracture Repair SystemHand Innovations, Inc.2002—
−9K030198Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−8K032705Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−7K050932Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc.20051
−6K051735Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper ExtremitySmith & Nephew, Inc.2005—
−5K071563Peri-Loc Periarticular Locked Plating SystemSmith & Nephew, Inc.2007—
−4K090675Smith & Nephew, Inc. VLP Foot Plating, Screw System and AccessoriesSmith & Nephew, Inc.2009—
−3K100776Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa)2010—
−2K112583Synthes Cortical ScrewsSynthes (USA) Products, LLC2011—
−1K161616DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm Cannulated…Synthes USA Products, LLC2017—
0 (this device)K190830TDM Screw SystemsTdm Co., Ltd.2019—
+1K231860TDM Screw SystemTdm Co., Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197920
198110
198930
199010
199110
199230
199320
199470
199570
1996140
199710
199870
199960
2000100
2001110
200280
200360
200450
200570
200690
200740
200840
200930
201030
201120
201210
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K190830, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K161616DePuy Synthes 4.0 mm and 4.5 mm Cortex Screws, DePuy Synthes 2.4 mm Cannulated Screws…
Summary page 4
…NAME HTN; 21 CFR§888.3030 Single/multiple component metallic bone fixation appliances and accessories PRIMARY PREDICATE K161616 Synthes Cannulated, Cortex, and Headless DEVICES Compression Screws ADDITIONAL PREDICATE K123890 Acumed Cannu…
Synthes USA Products, LLC2017—
*K123890Acumed Cannulated Screw System
Summary page 4
…appliances and accessories PRIMARY PREDICATE K161616 Synthes Cannulated, Cortex, and Headless DEVICES Compression Screws ADDITIONAL PREDICATE K123890 Acumed Cannulated Screw System DEVICES K021556 Synthes 2.4mm Cannulated Compression Screw…
Acumed, LLC20132
*K021556Synthes 2.4 MM Cannulated Compression Screw
Summary page 4
…nthes Cannulated, Cortex, and Headless DEVICES Compression Screws ADDITIONAL PREDICATE K123890 Acumed Cannulated Screw System DEVICES K021556 Synthes 2.4mm Cannulated Compression Screw K050636 Synthes 3.0mm Headless Compression Screws…
Synthes (Usa)2002—
*K050636Synthes 3.0MM Headless Compression Screws
Summary page 4
…Screws ADDITIONAL PREDICATE K123890 Acumed Cannulated Screw System DEVICES K021556 Synthes 2.4mm Cannulated Compression Screw K050636 Synthes 3.0mm Headless Compression Screws K080943 Synthes 4.5 mm and 6.5 mm Headless Compression…
Synthes (Usa)20051
*K080943Synthes 4.5 MM and 6.5 MM Headless Compression Screws
Summary page 4
…VICES K021556 Synthes 2.4mm Cannulated Compression Screw K050636 Synthes 3.0mm Headless Compression Screws K080943 Synthes 4.5 mm and 6.5 mm Headless Compression Screws K063020 INTAI Bone Screw Sy…
Synthes (Usa)2008—
*K063020Intai Bone Plate and Bone Screw System; Intai DHS/DCS Plate System
Summary page 4
…s 3.0mm Headless Compression Screws K080943 Synthes 4.5 mm and 6.5 mm Headless Compression Screws K063020 INTAI Bone Screw System DEVICE DESCRIPTION The TDM Screw Systems consist of a family of devices intended…
Intai Technology, Inc.2006—

Also cleared against K161616: 17 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K231860TDM Screw SystemTdm Co., Ltd.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 7 companies; a new generation was cleared every 1.8 years on median.
  • 23 of the 141 ancestors have a recall of any class.
  • Of its descendants, K231860 (Tdm Co., Ltd., 2024) has gone furthest, with 0 descendants of its own.
  • 17 other devices also cite its predicate K161616.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

The TDM Screw Systems are indicated for fixation of fractures, fusions, osteotomies, non-unions, and malunions of bones appropriate for the size of the device. Cannulated Screw System: The Cannulated Screw System is intended to be used for fracture of small bones of the hand or foot (2.5mm) or small and large bones (4.0mm larger). Headless Compression Cannulated Screw System: The Headless Compression Cannulated Screw System is intended to be used for a…

Read the full statement (135 words)

The TDM Screw Systems are indicated for fixation of fractures, fusions, osteotomies, non-unions, and malunions of bones appropriate for the size of the device.

Cannulated Screw System:

The Cannulated Screw System is intended to be used for fracture of small bones of the hand or foot (2.5mm) or small and large bones (4.0mm larger).

Headless Compression Cannulated Screw System:

The Headless Compression Cannulated Screw System is intended to be used for a wide range of different indications in the hand, wrist and joint fusion (arthrodeses) in the foot (2.3mm & 3.5mm, 3.0mm & 4.0mm) and fixation of intra-articular fractures of the humerus, femur and tibia (3.5mm & 5.0mm).

Limited Sliding Screw System:

The Limited Sliding Screw System is intended to be used for fracture fixation of the proximal femur, large bones and large bone fragments.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190830: TDM Screw Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K190830

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026