510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Sight OLO

K190898510(k) TraditionalCleared Nov 1, 2019210-day reviewClass II21 CFR 864.5220Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sight Diagnostics, Ltd. · GKZ Counter, Differential Cell

Cleared on Nov 1, 2019 as substantially equivalent to K112605 (Sysmex America, Inc., 2012) after a 210-day review. Its family tree reaches back 3 generations to 2004. 2 later devices descend from it. It has been recalled 4 times.

Decided
Nov 1, 2019
Review
210 days
Class
Class II
Product code
GKZ
Recalls
4
Predicates
1

Its longest line of descent runs back 3 generations to K040073 (2004). 2 later devices descend from it, 2 citing it directly.

  1. Root · 3 generations backK040073 Sysmex Automated Hematology Analyzer, XE-2100 Series (XE-2100…Sysmex America, Inc. · 2004
  2. 2 generations backK071967 Sysmex XE-5000Sysmex America, Inc. · 2007 · Recalled
  3. 1 generation backK112605 Sysmex XN-SeriesSysmex America, Inc. · 2012 · Recalled
  4. This deviceK190898 Sight OLOSight Diagnostics, Ltd. · 2019
  5. Descendant · cites it directly · 0 of its ownK251249 Tru Hematology TestTruvian Sciences, Inc. · 2026
  6. Descendant · cites it directly · 0 of its ownK211840 Sight OLOS.D. Sight Diagnostics, Ltd. · 2022 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K251249Tru Hematology TestTruvian Sciences, Inc. · 2026 · cites it directly0descendants
  • K211840Sight OLOS.D. Sight Diagnostics, Ltd. · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K040073Sysmex Automated Hematology Analyzer, XE-2100 Series (XE-2100, XE-2100L)Sysmex America, Inc.2004—
−2K071967Sysmex XE-5000Sysmex America, Inc.20071
−1K112605Sysmex XN-SeriesSysmex America, Inc.20122
0 (this device)K190898Sight OLOSight Diagnostics, Ltd.2019—
+1K251249Tru Hematology TestTruvian Sciences, Inc.2026—
+1K211840Sight OLOS.D. Sight Diagnostics, Ltd.20221

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202610
FIG. 1 — Lineage of K190898, 2004–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKZ device

  1. #1 K250943 Sysmex XR-Series (XR-10) Automated Hematology…score 13.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112605Sysmex XN-Series
Summary page 4
…nalyzer Classification: 21 CFR 864.5220, Class II, Product Code: GKZ Predicate Devices Sysmex® XN-Series (XN-10, XN-20) Automated Hematology Analyzers (K112605) Reference device PixCell Medical Technologies, Ltd.’s HemoScreen Hematology Analyzer (K180020) Device Description…
Sysmex America, Inc.20122
†K180020HemoScreen Hematology AnalyzerPixcell Medical Technologies, Ltd.2018—

Also cleared against K112605: 12 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K251249Tru Hematology TestTruvian Sciences, Inc.20260
K211840Sight OLOS.D. Sight Diagnostics, Ltd.20220

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 13, 2024Class IIZ-2173-2024Process controlOne Test Kit lot (TK1-10114) shows a positive bias in the platelet count due to bacterial contamination which can result in elevated counts with a bias of 7.5 k/ul. This results in the test kit lot performing outside of the device…
Jun 14, 2022Class IIZ-1469-2022Software Design ChangeThe default reference ranges for MCH, MCHC, and RDW for age group "Child 2-11y" are mixed up and incorrectly displayed on OLO devices running software version 2.63, 2.63.1, and 2.63.1.1. Due to the issue, results may incorrectly appear to…
Jan 20, 2022Class IIZ-0963-2022Software designIn instances where custom reference ranges were configured on the device post installation, a possibility to inadvertently apply changes to reference range values was found on software versions 2.59.3 and all earlier versions, which can…
Mar 17, 2021Class IIZ-2517-2021Labeling Change ControlDiscrepancy in labeling between the adult CBC reference ranges presented in the OLO Operator's Manual and the OLO software

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 2 companies; a new generation was cleared every 4.9 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K251249 (Truvian Sciences, Inc., 2026) has gone furthest, with 0 descendants of its own.
  • 12 other devices also cite its predicate K112605.

How does its category compare?

All GKZ devices

GKZ Counter, Differential Cell: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · GKZ

4in 2025

2007: 62008: 62009: 62010: 42011: 32012: 32013: 12014: 32015: 32016: 32017: 42018: 32019: 52020: 12022: 32023: 42024: 32025: 42026 (partial year): 4
2007high 6 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKZ

108in 2025

2007: 117 days median2008: 99 days median2009: 147 days median2010: 290 days median2011: 315 days median2012: 408 days median2014: 165 days median2015: 273 days median2016: 198 days median2017: 280 days median2018: 270 days median2019: 210 days median2022: 638 days median2023: 329 days median2024: 157 days median2025: 108 days median2026 (partial year): 254 days median
2007high 638 (2022) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GKZ

1in 2025

2007: 372008: 52009: 132010: 272011: 282012: 72013: 62015: 32016: 32017: 32018: 2, 2 Class I2019: 22020: 12022: 42023: 12025: 1
2007high 37 (2007) · low 0 (2014)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · GKZ

77in 2025

2007: 2682008: 9252009: 5592010: 8962011: 2,9052012: 2,9592013: 3,0702014: 3,1122015: 1,9722016: 3,3382017: 2292018: 4972019: 9082020: 3422021: 3912022: 1982023: 1552024: 1152025: 77
2007high 3,338 (2016) · low 77 (2025)2025

MAUDE reports naming product code GKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611737268
20086995925
2009614713559
2010429027896
20113315282,905
2012340872,959
20131—63,070
2014316503,112
2015327331,972
2016319833,338
201742803229
201832702 (2)497
201952102908
20201—1342
20210—0391
202236384198
202343291155
202431570115
20254108177
202642540—

What is it indicated for?

The Sight OLO is a quantitative multi-parameter automated hematology analyzer intended for in vitro diagnostic use in screening capillary or venous whole blood samples collected in K2EDTA blood collection tubes, or fingertip samples collected using the Sight OLO test kit micro-capillary tubes.

When used with the Sight OLO cartridge, the Sight OLO enumerates the following CBC parameters in whole blood: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, NEUT%/#, LYMPH %/#, MONO %/#, EOS%/#, and BASO%/#.

The Sight OLO is indicated for use in clinical laboratories to identify and classify one or more of the formed elements of blood in children 3 months and above, adolescents and adults.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190898: Sight OLO.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K190898

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026