510(k) Report

510(k) · Cleared

Cleared

Automatic Digital Blood Pressure Monitor

K190982510(k) TraditionalCleared May 29, 2020410-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Xiamen Ants Bro Technology Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on May 29, 2020 as substantially equivalent to K171833 (Shenzhen Combei Technology Co., Ltd., 2018) and 1 other predicate after a 410-day review. Its family tree reaches back 11 generations to 2000.

Decided
May 29, 2020
Review
410 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
2

Its longest line of descent runs back 11 generations to K001670 (2000). 24 ancestors in all, the oldest K982481 (1998). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2016: 1 other ancestor2013: 1 other ancestor2007: 1 other ancestor2012: 1 other ancestor2003: 1 other ancestor2009: 1 other ancestor2004: 1 other ancestor2000: 2 other ancestors2008: 1 other ancestor1998: 1 other ancestor2005: 1 other ancestor2002: 1 other ancestorK001670 · Automatic Blood Pressure Monitor with Intellisense, Model Hem-757 · Omron Healthcare, Inc. · 2000K030358 · KD-622 Fully Automatic Electronic Blood Pressure Monitor · Kodon (Tianjin)Electronic&Electrical Apparatus Co., · 2003K070828 · KD-595 Fully Automatic Electronic Blood Pressure Monitor · Kodon (Tianjin)Electronic&Electrical Apparatus Co., · 2007K080319 · KD-591 Fully Automatic Electronic Blood Pressure Monitor · Andon Health Co, Ltd. · 2008K090963 · Fully Automatic Electronic Blood Pressure Monitor, Model KD-556 · Andon Health Co, Ltd. · 2009K101950 · Fully Automatic Electronic Blood Pressure Monitor Model KD-930 · Andon Health Co, Ltd. · 2010K102939 · Fully Automatic Electronic Blood Pressure Monitor Model KD-931 · Andon Health Co, Ltd. · 2011K120672 · KD-936 Fully Automatic Wireless Blood Pressure Monitor · Andon Health Co, Ltd. · 2012K140067 · Qardioarm · Qardio, Inc. · 2014K150430 · Arm Blood Pressure Monitor, Wrist Blood Pressure Monitor · Fudakang Industrial Co., Ltd. · 2015K171833 · Digital Blood Pressure Monitor-Wrist Style · Shenzhen Combei Technology Co., Ltd. · 2018199520002005201020152020
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 1 other ancestor4 generations back: 2 other ancestors5 generations back: 3 other ancestors6 generations back: 2 other ancestors7 generations back: 1 other ancestor8 generations back: 1 other ancestor9 generations back: 1 other ancestor K171833 · Digital Blood Pressure Monitor-Wrist Style · Shenzhen Combei Technology Co., Ltd. · 2018K150430 · Arm Blood Pressure Monitor, Wrist Blood Pressure Monitor · Fudakang Industrial Co., Ltd. · 2015K140067 · Qardioarm · Qardio, Inc. · 2014K120672 · KD-936 Fully Automatic Wireless Blood Pressure Monitor · Andon Health Co, Ltd. · 2012K102939 · Fully Automatic Electronic Blood Pressure Monitor Model KD-931 · Andon Health Co, Ltd. · 2011K101950 · Fully Automatic Electronic Blood Pressure Monitor Model KD-930 · Andon Health Co, Ltd. · 2010K090963 · Fully Automatic Electronic Blood Pressure Monitor, Model KD-556 · Andon Health Co, Ltd. · 2009K080319 · KD-591 Fully Automatic Electronic Blood Pressure Monitor · Andon Health Co, Ltd. · 2008K070828 · KD-595 Fully Automatic Electronic Blood Pressure Monitor · Kodon (Tianjin)Electronic&Electrical Apparatus Co., · 2007K030358 · KD-622 Fully Automatic Electronic Blood Pressure Monitor · Kodon (Tianjin)Electronic&Electrical Apparatus Co., · 2003K001670 · Automatic Blood Pressure Monitor with Intellisense, Model Hem-757 · Omron Healthcare, Inc. · 2000−10−50
  1. Root · 11 generations backK001670 Automatic Blood Pressure Monitor with Intellisense, Model Hem-757Omron Healthcare, Inc. · 2000
  2. 7 generations between
  3. 3 generations backK140067 QardioarmQardio, Inc. · 2014
  4. 2 generations backK150430 Arm Blood Pressure Monitor, Wrist Blood Pressure MonitorFudakang Industrial Co., Ltd. · 2015
  5. 1 generation backK171833 Digital Blood Pressure Monitor-Wrist StyleShenzhen Combei Technology Co., Ltd. · 2018
  6. This deviceK190982 Automatic Digital Blood Pressure MonitorXiamen Ants Bro Technology Co., Ltd. · 2020
Show all 11 generations
  1. Root · 11 generations backK001670 Automatic Blood Pressure Monitor with Intellisense, Model Hem-757Omron Healthcare, Inc. · 2000
  2. 10 generations backK030358 KD-622 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co., · 2003
  3. 9 generations backK070828 KD-595 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co., · 2007
  4. 8 generations backK080319 KD-591 Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd. · 2008
  5. 7 generations backK090963 Fully Automatic Electronic Blood Pressure Monitor, Model KD-556Andon Health Co, Ltd. · 2009
  6. 6 generations backK101950 Fully Automatic Electronic Blood Pressure Monitor Model KD-930Andon Health Co, Ltd. · 2010
  7. 5 generations backK102939 Fully Automatic Electronic Blood Pressure Monitor Model KD-931Andon Health Co, Ltd. · 2011
  8. 4 generations backK120672 KD-936 Fully Automatic Wireless Blood Pressure MonitorAndon Health Co, Ltd. · 2012
  9. 3 generations backK140067 QardioarmQardio, Inc. · 2014
  10. 2 generations backK150430 Arm Blood Pressure Monitor, Wrist Blood Pressure MonitorFudakang Industrial Co., Ltd. · 2015
  11. 1 generation backK171833 Digital Blood Pressure Monitor-Wrist StyleShenzhen Combei Technology Co., Ltd. · 2018
  12. This deviceK190982 Automatic Digital Blood Pressure MonitorXiamen Ants Bro Technology Co., Ltd. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K001670Automatic Blood Pressure Monitor with Intellisense, Model Hem-757Omron Healthcare, Inc.2000—
−10K030358KD-622 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co.,2003—
−9K070828KD-595 Fully Automatic Electronic Blood Pressure MonitorKodon (Tianjin)Electronic&Electrical Apparatus Co.,2007—
−8K080319KD-591 Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd.2008—
−7K090963Fully Automatic Electronic Blood Pressure Monitor, Model KD-556Andon Health Co, Ltd.2009—
−6K101950Fully Automatic Electronic Blood Pressure Monitor Model KD-930Andon Health Co, Ltd.2010—
−5K102939Fully Automatic Electronic Blood Pressure Monitor Model KD-931Andon Health Co, Ltd.2011—
−4K120672KD-936 Fully Automatic Wireless Blood Pressure MonitorAndon Health Co, Ltd.2012—
−3K140067QardioarmQardio, Inc.2014—
−2K150430Arm Blood Pressure Monitor, Wrist Blood Pressure MonitorFudakang Industrial Co., Ltd.2015—
−1K171833Digital Blood Pressure Monitor-Wrist StyleShenzhen Combei Technology Co., Ltd.2018—
0 (this device)K190982Automatic Digital Blood Pressure MonitorXiamen Ants Bro Technology Co., Ltd.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200020
200210
200310
200410
200510
200710
200810
200910
201210
201310
201610
FIG. 1 — Lineage of K190982, 2000–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K171833Digital Blood Pressure Monitor-Wrist Style
Summary page 5
…be BP606W, BP660W, BP830W, BP866W A, B, C, D, E, F) 510(k) Number K171833 K153552 Product Code DXN DXN Regu…
Shenzhen Combei Technology Co., Ltd.2018—
*K153552AGE Automatic Upper Arm Blood Pressure Monitor
Summary page 5
…0W, BP866W A, B, C, D, E, F) 510(k) Number K171833 K153552 Product Code DXN DXN Regulation 870.1130…
Ageless Health Industrial Co., Ltd.2016—

Also cleared against K171833: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 7 companies; a new generation was cleared every 1.3 years on median.
  • None of the 24 ancestors has a recall.
  • 1 other device also cites its predicate K171833.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

Automatic Digital Blood Pressure Monitor is intended to measure the systolic and diastolic blood pressure as well as the pulse rate of adult person via non-invasive oscillometric technique in which an inflatable cuff is wrapped around the wrist or the upper arm. It can be used at medical facilities or at home. The intended wrist circumference is 12.5~20 cm and the intended arm circumference has several models: 23~33 cm, 25~35 cm, 22~42 cm, 33~43 cm .

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190982: Automatic Digital Blood Pressure Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K190982

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026