510(k) Report

510(k) · Cleared

Cleared

Stryker MIS and Footed Attachments

K191049510(k) TraditionalCleared Jun 18, 201960-day reviewClass II21 CFR 882.4310

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stryker Corporation · HBE Drills, Burrs, Trephines & Accessories (Simple, Powered)

Cleared on Jun 18, 2019 as substantially equivalent to K143540 (Stryker Corporation, 2015) and 1 other predicate after a 60-day review. Its family tree reaches back 2 generations to 2012.

Decided
Jun 18, 2019
Review
60 days
Class
Class II
Product code
HBE
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K112593 (2012). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2015: 1 other ancestorK112593 · Styker Consolidated Operating Room Equipment (Core) System · Stryker Corporation · 2012K143540 · Stryker MIS Attachments and Cutting Accessories · Stryker Corporation · 2015201020122014201620182020
  1. Root · 2 generations backK112593 Styker Consolidated Operating Room Equipment (Core) SystemStryker Corporation · 2012
  2. 1 generation backK143540 Stryker MIS Attachments and Cutting AccessoriesStryker Corporation · 2015
  3. This deviceK191049 Stryker MIS and Footed AttachmentsStryker Corporation · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K112593Styker Consolidated Operating Room Equipment (Core) SystemStryker Corporation2012—
−1K143540Stryker MIS Attachments and Cutting AccessoriesStryker Corporation2015—
0 (this device)K191049Stryker MIS and Footed AttachmentsStryker Corporation2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201510
FIG. 1 — Lineage of K191049, 2012–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HBE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HBE device

  1. #1 K251433 Surgify Halo (54.085.SHD.H1); Surgify Halo…score 13.1 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143540Stryker MIS Attachments and Cutting Accessories
Summary page 6
…269-324-5412 www.stryker.com III. PREDICATE DEVICE 510 (K) Number Product code Trade name Manufacturer K143540 HBE, ERL Stryker® MIS Stryker Instruments…
Stryker Corporation2015—
*K143399Stryker Footed Attachments and Cutting Accessories
Summary page 6
…Stryker Instruments Attachments and cutting accessories K143399 HBE, ERL Stryker® Footed Stryker Instruments…
Stryker Corp.20151

Also cleared against K143540: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 4.1 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K143540.

How does its category compare?

All HBE devices

HBE Drills, Burrs, Trephines & Accessories (Simple, Powered): FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · HBE

6in 2025

2007: 22008: 22011: 22012: 12013: 12014: 22015: 32016: 22017: 22018: 22019: 52021: 62022: 22023: 22025: 62026 (partial year): 1
2007high 6 (2021) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HBE

30in 2025

2015: 155 days median2019: 133 days median2021: 193 days median2025: 30 days median
2007high 193 (2021) · low 30 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HBE

1in 2024

2008: 472009: 72010: 232011: 12012: 262013: 42016: 72017: 32021: 12023: 32024: 12026 (partial year): 19
2007high 47 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HBE

1,924in 2025

2007: 142008: 142009: 2422010: 4922011: 1,0132012: 1,1462013: 1,5832014: 5592015: 4832016: 8482017: 8482018: 7872019: 8362020: 1,0252021: 1,0472022: 9002023: 9482024: 1,1532025: 1,924
2007high 1,924 (2025) · low 14 (2007)2025

MAUDE reports naming product code HBE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—014
20082—4714
20090—7242
20100—23492
20112—11,013
20121—261,146
20131—41,583
20142—0559
201531550483
20162—7848
20172—3848
20182—0787
201951330836
20200—01,025
2021619311,047
20222—0900
20232—3948
20240—11,153
202563001,924
20261—19—

What is it indicated for?

The MIS Attachments and Cutting Accessories are intended to be used with the Stryker Consolidated Operating Room Equipment (CORE®) Console and electric and pneumatic motors. When used with these motors, the MIS Attachments and Cutting Accessories are intended to cut bone in the following manner: drilling, reaming, decorticating, shaping, dissecting, shaving, and smoothing for the following medical applications: Neuro; Spine; Ear, Nose, and Throat…

Read the full statement (236 words)

The MIS Attachments and Cutting Accessories are intended to be used with the Stryker Consolidated Operating Room Equipment (CORE®) Console and electric and pneumatic motors. When used with these motors, the MIS Attachments and Cutting Accessories are intended to cut bone in the following manner: drilling, reaming, decorticating, shaping, dissecting, shaving, and smoothing for the following medical applications: Neuro; Spine; Ear, Nose, and Throat (ENT)/Otorhinolaryngology; and Endoscopic applications.

Specific applications include Craniotomy/Craniectomy, Laminotomy/Laminectomy, Minimally Invasive Surgery (MIS) Spine, Expanded Endonasal Approach (EEA)/Anterior Skull Base/ Endoscopic/Transnasal/Transphenoidal, and Orthopedic Spine.

These devices are also usable in the preparation for the placement of screws, metal, wires, pins, and other fixation devices.

The Footed Attachments and Cutting Accessories are intended to be used with the Stryker Consolidated Operating Room Equipment (CORE®) Console and electric and pneumatic motors. When used with these motors, the Footed Attachments and Cutting Accessories are intended to cut bone in the following manner: drilling, reaming, dissecting, and shaping for the following medical applications: Neuro; Spine; Ear, Nose, and Throat (ENT) /Otology /Neurotology/Otorhinolaryngology; Craniofacial and Maxillofacial; and Sternotomy.

Specific applications include Craniotomy/Craniectomy, Pterional Craniotomy, Sub Occipital/Retro Sigmoid/Posterior Fossa Craniotomy, Sphenoid Wing Dissection, Laminotomy / Laminectomy, and Orthopedic Spine.

These devices are also usable in the preparation for the placement of screws, metal, wires, pins, and other fixation devices.

It is also usable in the preparation for the placement of screws, metal, wires, pins, and other fixation devices.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K191049: Stryker MIS and Footed Attachments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K191049

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026