510(k) Report

510(k) · Decided

Decided

Ureteral Stent Systems, Biliary Drainage Catheters

K191446510(k) TraditionalDecided Jan 2, 2020216-day reviewClass II21 CFR 876.4620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corporation · FAD Stent, Ureteral

Cleared on Jan 2, 2020 as substantially equivalent to K023870 (Boston Scientific/Medi-Tech, 2002) and 1 other predicate after a 216-day review. Its family tree reaches back 1 generation to 1994.

Decided
Jan 2, 2020
Review
216 days
Class
Class II
Product code
FAD
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K944290 (1994). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2002: 1 other ancestorK944290 · Catheters, Biliary Catheters, Urological · Boston Scientific Corp · 1994 · recalled1990199520002005201020152020
Other ancestors, by generation 1 generation back: 1 other ancestor K944290 · Catheters, Biliary Catheters, Urological · Boston Scientific Corp · 1994 · recalled0
  1. Root · 1 generation backK944290 Catheters, Biliary Catheters, UrologicalBoston Scientific Corp · 1994 · Recalled
  2. This deviceK191446 Ureteral Stent Systems, Biliary Drainage CathetersBoston Scientific Corporation · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K944290Catheters, Biliary Catheters, UrologicalBoston Scientific Corp19945
0 (this device)K191446Ureteral Stent Systems, Biliary Drainage CathetersBoston Scientific Corporation2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
FIG. 1 — Lineage of K191446, 1994–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FAD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FAD device

  1. #1 K251890 Disposable Ureteral Stentsscore 12.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023870Flexima Biliary Catheter
Summary page 7
…FAD stent, ureteral II Systems 876.4620 III. PREDICATE DEVICE IDENTIFICATION Name of Predicate Device Flexima Biliary Catheter K023870 (Predicate for Flexima Biliary Catheters) Flexima Drainage Catheters and Stents K944290 (Predicate for Flexima Ureteral Stents)…
Boston Scientific/Medi-Tech20022
*K944290Catheters, Biliary Catheters, Urological
Summary page 7
…DICATE DEVICE IDENTIFICATION Name of Predicate Device Flexima Biliary Catheter K023870 (Predicate for Flexima Biliary Catheters) Flexima Drainage Catheters and Stents K944290 (Predicate for Flexima Ureteral Stents) Predicate devices referenced above have not been subject to a design-related recall. IV…
Boston Scientific Corp19945

Also cleared against K023870: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 2 of the 2 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K023870.

How does its category compare?

All FAD devices

FAD Stent, Ureteral: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · FAD

4in 2025

2007: 12008: 12010: 12014: 12016: 42017: 82018: 92019: 52020: 12021: 22022: 52024: 12025: 42026 (partial year): 1
2007high 9 (2018) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FAD

186in 2025

2016: 143 days median2017: 266 days median2018: 258 days median2019: 263 days median2022: 143 days median2025: 186 days median
2007high 266 (2017) · low 143 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FAD

4in 2025

2007: 12008: 222009: 22010: 12016: 42019: 62020: 22021: 12022: 92025: 4
2007high 22 (2008) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FAD

634in 2025

2007: 432008: 762009: 1232010: 782011: 952012: 1312013: 822014: 782015: 1302016: 1822017: 2652018: 2772019: 2612020: 3522021: 5312022: 5592023: 6912024: 6032025: 634
2007high 691 (2023) · low 43 (2007)2025

MAUDE reports naming product code FAD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—143
20081—2276
20090—2123
20101—178
20110—095
20120—0131
20130—082
20141—078
20150—0130
201641434182
201782660265
201892580277
201952636261
20201—2352
20212—1531
202251439559
20230—0691
20241—0603
202541864634
20261—0—

What is it indicated for?

The Flexima™ Ureteral Stent System and Flexima™ Ureteral Stent System Kit is intended to provide drainage from the ureteropelvic junction to the bladder and stenting of the ureter for all patients in whom it is desirable to place a drain which does not extend externally.

The Flexima™ Biliary Catheter System / Flexima™ Biliary Catheter System Kit / Flexima™ Biliary Catheter System with Radiopaque Marker / Flexima™ Biliary Catheter System with Hydrophilic Dissolving Tip / Flexima™ Biliary Catheter System with Hydrophilic Dissolving Tip and Radiopaque Marker are intended to provide external and internal percutaneous drainage of the biliary system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K191446: Ureteral Stent Systems, Biliary Drainage Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K191446

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026