510(k) · Cleared
ClearedOkami Medical LOBO Vascular Occlusion System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Okami Medical · KRD Device, Vascular, For Promoting Embolization
Cleared on Oct 30, 2019 after an 89-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it.
- Decided
- Oct 30, 2019
- Review
- 89 days
- Class
- Class II
- Product code
- KRD
- Recalls
- None
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK192083 Okami Medical LOBO Vascular Occlusion SystemOkami Medical · 2019
- Descendant · cites it directly · 0 of its ownK260508 LOBO Vascular Occlusion SystemOkami Medical, Inc. · 2026
Most influential descendants
Showing 1 of 1 · See all- K260508LOBO Vascular Occlusion SystemOkami Medical, Inc. · 2026 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K192083 | Okami Medical LOBO Vascular Occlusion System | Okami Medical | 2019 | — |
| +1 | K260508 | LOBO Vascular Occlusion System | Okami Medical, Inc. | 2026 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KRD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KRD device
- #1 K253511 Concerto Versa™ Detachable Coilscore 17.6 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K260508 | LOBO Vascular Occlusion System | 2026 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K260508 (Okami Medical, Inc., 2026) has gone furthest, with 0 descendants of its own.
How does its category compare?
All KRD devicesKRD Device, Vascular, For Promoting Embolization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · KRD
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KRD
60in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KRD
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KRD
1,572in 2025
MAUDE reports naming product code KRD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 21 |
| 2008 | 5 | 84 | 0 | 14 |
| 2009 | 4 | 27 | 0 | 40 |
| 2010 | 3 | 150 | 1 | 61 |
| 2011 | 5 | 36 | 0 | 102 |
| 2012 | 8 | 30 | 0 | 137 |
| 2013 | 11 | 33 | 1 | 244 |
| 2014 | 7 | 134 | 0 | 159 |
| 2015 | 11 | 130 | 0 | 337 |
| 2016 | 4 | 164 | 0 | 437 |
| 2017 | 4 | 89 | 0 | 736 |
| 2018 | 4 | 62 | 0 | 1,066 |
| 2019 | 6 | 178 | 0 | 1,185 |
| 2020 | 4 | 137 | 0 | 1,167 |
| 2021 | 3 | 134 | 0 | 1,444 |
| 2022 | 8 | 175 | 0 | 1,498 |
| 2023 | 2 | — | 1 | 1,371 |
| 2024 | 6 | 70 | 1 | 1,535 |
| 2025 | 9 | 60 | 0 | 1,572 |
| 2026 | 7 | 70 | 1 | — |
What is it indicated for?
Intended Use: The Okami Medical LOBO Vascular Occlusion System is intended for use to obstruct or reduce the rate of blood flow in arteries of the peripheral vasculature. The device is not indicated for use in blood vessels where crush or bend forces are anticipated (e.g. joint areas, superficial vasculature).
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K192083 · printed Nov 6, 2026
Cite this page
510(k) Report. “K192083: Okami Medical LOBO Vascular Occlusion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192083
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026