510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

RAPIDPoint 500e Blood Gas System

K192240510(k) SpecialCleared Mar 27, 2020221-day reviewClass II21 CFR 862.1120Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics, Inc. · CHL Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph

Cleared on Mar 27, 2020 as substantially equivalent to K122539 (Siemens Healthcare Diagnostics, 2013) after a 221-day review. Its family tree reaches back 4 generations to 1987. 3 later devices descend from it. It has been recalled 4 times.

Decided
Mar 27, 2020
Review
221 days
Class
Class II
Product code
CHL
Recalls
4
Predicates
1

Its longest line of descent runs back 4 generations to K872888 (1987). 5 ancestors in all. 3 later devices descend from it, 2 citing it directly.

  1. Root · 4 generations backK872888 Ciba Corning 288 PH/Blood Gas SystemCiba Corning Diagnostics Corp. · 1987
  2. 3 generations backK050423 Omni Modular, Omni C and Omni S Analyzer (PH Electrode)Roche Diagnostics · 2005
  3. 2 generations backK110416 ABL835 Flex Analyzer with Pleural PHRadiometer Medical Aps · 2011 · Recalled
  4. 1 generation backK122539 Measurement of PH in Pleural Fluid on Blood Gas SystemSiemens Healthcare Diagnostics · 2013
  5. This deviceK192240 RAPIDPoint 500e Blood Gas SystemSiemens Healthcare Diagnostics, Inc. · 2020
  6. Descendant · cites it directly · 1 of its ownK223857 i-STAT G3+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2023 · Recalled
  7. Descendant · 2 generations on · 0 of its ownK244014 i-STAT CG4+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2025 · Recalled
  8. Descendant · cites it directly · 0 of its ownK230285 i-STAT CG8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2023

Most influential descendants

Showing 3 of 3 · See all
  • K223857i-STAT G3+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2023 · cites it directly1descendant
  • K244014i-STAT CG4+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2025 · 2 generations on0descendants
  • K230285i-STAT CG8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K872888Ciba Corning 288 PH/Blood Gas SystemCiba Corning Diagnostics Corp.1987—
−3K050423Omni Modular, Omni C and Omni S Analyzer (PH Electrode)Roche Diagnostics2005—
−2K110416ABL835 Flex Analyzer with Pleural PHRadiometer Medical Aps20112
−1K122539Measurement of PH in Pleural Fluid on Blood Gas SystemSiemens Healthcare Diagnostics2013—
0 (this device)K192240RAPIDPoint 500e Blood Gas SystemSiemens Healthcare Diagnostics, Inc.2020—
+1K223857i-STAT G3+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.20231
+2K244014i-STAT CG4+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.20251
+1K230285i-STAT CG8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202320
202510
FIG. 1 — Lineage of K192240, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CHL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CHL device

  1. #1 K252207 ABL90 FLEX PLUS System, safeCLINITUBESscore 14.1 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122539Measurement of PH in Pleural Fluid on Blood Gas System
Summary page 10
…Blood Gasses (pCO2) (pO2) and Blood pH Test System FDA Product Codes CHL, JGS, CEM, JFP, CGZ, CGA, GKR, MQM, KHP 510(k) Number K122539 Manufacturer Siemens Healthcare Diagnostics Inc. The RAPIDPoint 500e Blood Gas System is substanti…
Siemens Healthcare Diagnostics2013—

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223857i-STAT G3+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.20231
K230285i-STAT CG8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.20230

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 17, 2024Class IIZ-2214-2024Software Design ChangeSiemens Healthineers has identified an issue with the RAPIDPoint500e system software version 5.3. This issue affects how the sample source is identified at the LIS when using the capillary mode. With this software version, samples run in…
Sep 26, 2023Class IIZ-0422-2024Under Investigation by firmThere are potential drug interferences from Perhexiline Maleate or Atomoxetine Hydrochloride that may cause falsely elevated sodium results reported on the RAPIDPoint 500 and RAPIDPoint 500e Blood Gas Systems. The erroneous sodium levels…
Jun 1, 2022Class IIZ-1372-2022Under Investigation by firmDiscrepant (low bias) pO2 results, could be an incorrect diagnosis of hypoxemia and initiation of unnecessary or inappropriate respiratory support.
May 27, 2020Class IIZ-2432-2020Software designThe scanner is not confirming the integrity of read barcode data using the check-digit when reading Code 39 barcodes.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 5 companies; a new generation was cleared every 6.9 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • Of its descendants, K223857 (Abbott Point of Care, Inc., 2023) has gone furthest, with 1 descendant of its own.

How does its category compare?

All CHL devices

CHL Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · CHL

1in 2025

2007: 12008: 12010: 12011: 42012: 42013: 52014: 32015: 42016: 32017: 12018: 12020: 42021: 22023: 52024: 12025: 12026 (partial year): 1
2007high 5 (2013) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CHL

267in 2023

2011: 108 days median2012: 65 days median2013: 152 days median2014: 68 days median2015: 155 days median2016: 306 days median2020: 100 days median2023: 267 days median
2007high 306 (2016) · low 65 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CHL

13so far in 2026, the most since 2007

2007: 62008: 52009: 62010: 72011: 12012: 92013: 12014: 12015: 32016: 12017: 12018: 32020: 22023: 42024: 92026 (partial year): 13
2007high 13 (2026) · low 0 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CHL

210in 2025

2007: 162008: 402009: 742010: 202011: 502012: 642013: 622014: 932015: 552016: 1182017: 2062018: 1742019: 1412020: 1172021: 1472022: 1382023: 1772024: 1962025: 210
2007high 210 (2025) · low 16 (2007)2025

MAUDE reports naming product code CHL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—616
20081—540
20090—674
20101—720
20114108150
2012465964
20135152162
2014368193
20154155355
201633061118
20171—1206
20181—3174
20190—0141
202041002117
20212—0147
20220—0138
202352674177
20241—9196
20251—0210
20261—13—

What is it indicated for?

The RAPIDPoint® 500e Blood Gas System is intended for in vitro diagnostic use and is designed to provide the determination in whole blood for the following parameters: • Partial pressure of carbon dioxide • Partial pressure of oxygen • pH • Sodium • Potassium • Ionized Calcium • Chloride • Glucose • Lactate • Total Hemoglobin and fractions: FO2Hb, FCOHb, FMetHb, FHHb • Neonatal Bilirubin The RAPIDPoint 500e Blood Gas System is also intended for in vitro…

Read the full statement (517 words)

The RAPIDPoint® 500e Blood Gas System is intended for in vitro diagnostic use and is designed to provide the determination in whole blood for the following parameters:

• Partial pressure of carbon dioxide

• Partial pressure of oxygen

• pH

• Sodium

• Potassium

• Ionized Calcium

• Chloride

• Glucose

• Lactate

• Total Hemoglobin and fractions: FO2Hb, FCOHb, FMetHb, FHHb

• Neonatal Bilirubin

The RAPIDPoint 500e Blood Gas System is also intended for in vitro testing of pleural fluid samples for the pH parameter. The pH measurement of pleural fluid can be a clinically useful tool in the management of patients with parapneumonic effusions.

The following critical value applies to pleural fluid pH: pH > 7.3 is measured in uncomplicated parapneumonic effusions. All pleural fluids with a pH measurement < 7.3 are referred to as complicated parapneumonic effusions and are exudative in nature. This test system is intended for use in point of care or laboratory settings.

The following list includes the Indications for Use information for each analyte measured on the RAPIDPoint 500e Blood Gas System:

Lactate: A lactic acid test system is a device intended to measure lactic acid in whole blood. Lactic acid measurements that evaluate the acid-base status are used in the diagnosis and treatment of lactic acidosis (abnormally high acidity of the blood).

Neonate Bilirubin: A bilirubin (total and unbound) in the neonate test system is a device intended to measure the levels of bilirubin (total and unbound) in the blood (serum) of newborn infants to aid in indicating the risk of bilirubin encephalopathy (kernicterus).

pCO2, p02, pH: Measurements of blood gases (pCO2, p02) and blood pH are used in the diagnosis and treatment of life-threatening acid-base disturbances.

Sodium: Sodium measurements obtained by this device are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance.

Potassium: Potassium measurements obtained by this device are used to monitor electrolyte balance in the diagnosis and treatment of diseases conditions characterized by low or high blood potassium levels.

Chloride: Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis.

Ionized calcium: Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms).

Glucose: Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Total hemoglobin: Total hemoglobin measurements are used to determine the hemoglobin content of human blood.

Oxyhemoglobin: Oxyhemoglobin measurements are used to measure the hemoglobin content of whole blood for the detection of anemia.

Carboxyhemoglobin: Carboxyhemoglobin measurements are used to determine the carboxyhemoglobin (the compound formed when hemoglobin is exposed to carbon monoxide) content of human blood as an aid in the diagnosis of carbon monoxide poisoning.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K192240: RAPIDPoint 500e Blood Gas System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192240

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026