Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential, Powder-Free Exam Gloves Tested for Use with Chemotherapy Drugs and Fentanyl Citrate

K192241510(k) AbbreviatedCleared Mar 13, 2020207-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

O&M Haylard, Inc. · LZA Polymer Patient Examination Glove

Cleared on Mar 13, 2020 as substantially equivalent to K102032 (Kimberly-Clark Corp., 2010) after a 207-day review. Its family tree reaches back 3 generations to 1999.

Decided
Mar 13, 2020
Review
207 days
Class
Class I
Product code
LZA
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K992062 (1999). 7 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK992062 Safeskin Sterile Purple Nitrile Examination GlovesSafeskin Corp. · 1999
  2. 2 generations backK081027 Kimberly-Clark Sterling Nitrile Powder-Free Exam Glove (Sterile)Kimberly-Clark Corp. · 2008 · Recalled
  3. 1 generation backK102032 Kimberly-Clark Purple Nitrile Xtra* Sterile Powder-Free Exam Glove…Kimberly-Clark Corp. · 2010
  4. This deviceK192241 Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential…O&M Haylard, Inc. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K992062Safeskin Sterile Purple Nitrile Examination GlovesSafeskin Corp.1999—
−2K081027Kimberly-Clark Sterling Nitrile Powder-Free Exam Glove (Sterile)Kimberly-Clark Corp.20081
−1K102032Kimberly-Clark Purple Nitrile Xtra* Sterile Powder-Free Exam Glove…Kimberly-Clark Corp.2010—
0 (this device)K192241Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential, Powder-Free…O&M Haylard, Inc.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
200410
200510
200810
FIG. 1 — Lineage of K192241, 1999–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZA device

  1. #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102032Kimberly-Clark Purple Nitrile Xtra* Sterile Powder-Free Exam Glove (Chemotherapy Glove)…
Summary page 5
…QDO Class I, 21 CFR §880.6250 Fentanyl and other opioid protection glove Predicate Device K102032 KIMBERLY-CLARK PURPLE NITRILE XTRA* STERILE POWDER-FREE EXAM GLOVE (CHE…
Kimberly-Clark Corp.2010—

Also cleared against K102032: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 8.8 years on median.
  • 1 of the 7 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K102032.

How does its category compare?

All LZA devices

LZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · LZA

24in 2025

2007: 212008: 182009: 282010: 312011: 262012: 332013: 202014: 272015: 202016: 302017: 442018: 222019: 252020: 302021: 1392022: 1462023: 622024: 302025: 242026 (partial year): 15
2007high 146 (2022) · low 18 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZA

110in 2025

2007: 95 days median2008: 97 days median2009: 112 days median2010: 97 days median2011: 122 days median2012: 110 days median2013: 130 days median2014: 197 days median2015: 112 days median2016: 171 days median2017: 124 days median2018: 178 days median2019: 212 days median2020: 101 days median2021: 111 days median2022: 111 days median2023: 92 days median2024: 89 days median2025: 110 days median2026 (partial year): 103 days median
2007high 212 (2019) · low 89 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZA

3so far in 2026, the most since 2007

2015: 12016: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZA

73in 2025

2007: 72008: 22009: 122010: 122011: 92012: 112013: 102014: 82015: 122016: 252017: 42018: 32019: 212020: 42021: 202022: 192023: 242024: 762025: 73
2007high 76 (2024) · low 2 (2008)2025

MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007219507
2008189702
200928112012
20103197012
20112612209
201233110011
201320130010
20142719708
201520112112
201630171125
20174412404
20182217803
201925212021
20203010104
2021139111020
2022146111019
20236292024
20243089076
202524110073
2026151033—

What is it indicated for?

The Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential, Powder-Free Exam Gloves Tested for Use with Chemotherapy Drugs and Fentanyl Citrate are disposable devices intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. These gloves were tested for use with the following chemotherapy drugs and Fentanyl Citrate as per ASTM -D6978-05: Arsenic Trioxide (1 mg/ml) No breakthrough up…

Read the full statement (550 words)

The Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential, Powder-Free Exam Gloves Tested for Use with Chemotherapy Drugs and Fentanyl Citrate are disposable devices intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. These gloves were tested for use with the following chemotherapy drugs and Fentanyl Citrate as per ASTM -D6978-05:

Arsenic Trioxide (1 mg/ml) No breakthrough up to 240 minutes

Azacitidine (Vidaza) (25 mg/ml) No breakthrough up to 240 minutes

Bendamustine (5 mg/ml) No breakthrough up to 240 minutes

Bortezomib (Velcade) (1 mg/ml) No breakthrough up to 240 minutes

Bleomycin sulfate (15 mg/ml) No breakthrough up to 240 minutes

Busulfan (6 mg/ml) No breakthrough up to 240 minutes

Carboplatin (10 mg/ml) No breakthrough up to 240 minutes

Carfilzomib (2 mg/ml) No breakthrough up to 240 minutes

Carmustine (3.3 mg/ml) permeation occurred at 169.8 minutes

Cetuximab (Erbitux) (2 mg/ml) No breakthrough up to 240 minutes

Cisplatin (1 mg/ml) No breakthrough up to 240 minutes

Cladribine (1.0 mg/ml) No breakthrough up to 240 minutes

Cyclophosphamide (20 mg/ml) No breakthrough up to 240 minutes

Cytarabine HCL (100 mg/ml) No breakthrough up to 240 minutes

Cytovene (10 mg/ml) No breakthrough up to 240 minutes

Dacarbazine (10 mg/ml) No breakthrough up to 240 minutes

Daunorubicin HCL (5 mg/ml) No breakthrough up to 240 minutes

Decitabine (5 mg/ml) No breakthrough up to 240 minutes

Docetaxel (10 mg/ml) No breakthrough up to 240 minutes

Doxorubicin HCL (2 mg/ml) No breakthrough up to 240 minutes

Epirubicin (Ellence) (2 mg/ml) No breakthrough up to 240 minutes

Etoposide (20 mg/ml) No breakthrough up to 240 minutes

Fludarabine (25 mg/ml) No breakthrough up to 240 minutes

Fluorouracil (50 mg/ml) No breakthrough up to 240 minutes

Fulvestrant (50 mg/ml) No breakthrough up to 240 minutes

Gemcitabine (38 mg/ml) No breakthrough up to 240 minutes

Idarubicin (1 mg/ml) No breakthrough up to 240 minutes

Ifosfamide (50 mg/ml) No breakthrough up to 240 minutes

Irinotecan (20 mg/ml) No breakthrough up to 240 minutes

Mechlorethamine HCL (1 mg/ml) No breakthrough up to 240 minutes

Melphalan (5 mg/ml) No breakthrough up to 240 minutes

Methotrexate (25 mg/ml) No breakthrough up to 240 minutes

Mitomycin-C (0.5 mg/ml) No breakthrough up to 240 minutes

Mitoxantrone (2 mg/ml) No breakthrough up to 240 minutes

Oxaliplatin (2 mg/ml) No breakthrough up to 240 minutes

Paclitaxel (6 mg/ml) No breakthrough up to 240 minutes

Paraplatin (10 mg/ml) No breakthrough up to 240 minutes

Pemetrexed (25 mg/ml) No breakthrough up to 240 minutes

Pertuzumab (30 mg/ml) No breakthrough up to 240 minutes

Raltitrexed (0.5 mg/ml) No breakthrough up to 240 minutes

Retrovir (10 mg/ml) No breakthrough up to 240 minutes

Rituximab (10 mg/ml) No breakthrough up to 240 minutes

Temsirolimus (25 mg/ml) No breakthrough up to 240 minutes

Trastuzumab (21 mg/ml) No breakthrough up to 240 minutes

ThioTEPA (10 mg/ml) No breakthrough up to 240 minutes

Topotecan HCL (1 mg/ml) No breakthrough up to 240 minutes

Triclosan (1 mg/ml) No breakthrough up to 240 minutes

Trisenox (0.1 mg/ml) No breakthrough up to 240 minutes

Vincrinstine Sulfate (1 mg/ml) No breakthrough up to 240 minutes

Vinblastine (1 mg/ml) No breakthrough up to 240 minutes

Vinorelbine (10 mg/ml) No breakthrough up to 240 minutes

Zoledronic Acid (0.8 mg/ml) No breakthrough up to 240 minutes

Fentanyl Citrate (100mcg/2ml) No breakthrough up to 240 minutes.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K192241: Halyard Purple Xtra and Purple Sterile, Low Dermatitis Potential, Powder-Free Exam Gloves Tested for Use with Chemotherapy Drugs and Fentanyl Citrate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192241

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026