510(k) Report

510(k) · Cleared

Cleared

Innovo

K192357510(k) TraditionalCleared Jan 16, 2020140-day reviewClass II21 CFR 876.5330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Atlantic Therapeutics, Ltd. · QAJ Cutaneous Electrode Stimulator For Urinary Incontinence

Cleared on Jan 16, 2020 as substantially equivalent to DEN170049 (Bio-Medical Research, Ltd., 2018) after a 140-day review. Its family tree reaches back 1 generation to 2018.

Decided
Jan 16, 2020
Review
140 days
Class
Class II
Product code
QAJ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to DEN170049 (2018). No later device cites it as a predicate yet.

DEN170049 · Innovo · Bio-Medical Research, Ltd. · 20180
  1. Root · 1 generation backDEN170049 InnovoBio-Medical Research, Ltd. · 2018
  2. This deviceK192357 InnovoAtlantic Therapeutics, Ltd. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1DEN170049InnovoBio-Medical Research, Ltd.2018—
0 (this device)K192357InnovoAtlantic Therapeutics, Ltd.2020—
FIG. 1 — Lineage of K192357, 2018–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAJ device

  1. #1 K253285 Elitone for Menscore 11.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN170049Innovo
Summary page 4
…Class II Product Code: QAJ III. Predicate Devices: Name of Device: INNOVO®, Type Number 208 (DEN 170049) Common Name or Usual Name: Cutaneous Electrode Stimulator for Urinary…
Bio-Medical Research, Ltd.2018—
†K183585Elitone DeviceElidah, Inc.2019—

Also cleared against DEN170049: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate DEN170049.

How does its category compare?

All QAJ devices

QAJ Cutaneous Electrode Stimulator For Urinary Incontinence: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · QAJ

1in 2023

2018: 12019: 12020: 12023: 12026 (partial year): 1
2007high 1 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAJ

Too few QAJ 510(k)s in any year since 2007 to give a median.

Recalls per year · QAJ

No recall names QAJ since 2007.

Adverse event reports per year · QAJ

1in 2024

2022: 62023: 52024: 1
2007high 6 (2022) · low 0 (2007)2025

MAUDE reports naming product code QAJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20181—00
20191—00
20201—00
20210—00
20220—06
20231—05
20240—01
20250—00
20261—0—

What is it indicated for?

The INNOVO® is a transcutaneous electrical stimulator indicated for the treatment of stress urinary incontinence in adult

females.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K192357: Innovo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192357

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026