510(k) · Cleared
ClearedExsomed Wrist Plating System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Exsomed Corporation · HRS Plate, Fixation, Bone
Cleared on Dec 3, 2019 as substantially equivalent to K030310 (Synthes (Usa), 2003) and 1 other predicate after an 84-day review. Its family tree reaches back 1 generation to 2003.
- Decided
- Dec 3, 2019
- Review
- 84 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K030310 (2003). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK030310 Synthes Stainless Steel Modular Hand SystemSynthes (Usa) · 2003
- This deviceK192473 Exsomed Wrist Plating SystemExsomed Corporation · 2019
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K030310 | Synthes Stainless Steel Modular Hand System | Synthes (Usa) | 2003 | — |
| 0 (this device) | K192473 | Exsomed Wrist Plating System | Exsomed Corporation | 2019 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K030310 | Synthes Stainless Steel Modular Hand SystemSummary page 4…sterile. Predicate Devices: The primary predicate device is the existing Synthes Modular Hand System cleared under 510(k) K030310. Additional predicates include the BIOMET ALPS Hand Fracture System (K081546) and reference device Exsom… | 2003 |
| * | K081546 | Small Bone Locking Plating SystemSummary page 4…s Modular Hand System cleared under 510(k) K030310. Additional predicates include the BIOMET ALPS Hand Fracture System (K081546) and reference device Exsomed Innate (K171558). Indications for Use: The Exsomed Wrist Plating Syst… | 2008 |
| † | K171558 | ExsoMed ITN Cannulated Screw System | 2017 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- 1 of the 2 ancestors has a recall of any class.
- 15 other devices also cite its predicate K030310.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The Exsomed Wrist Plating System is intended for the repair of fractures and fusions of the hand and wrist.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K192473 · printed Nov 5, 2026
Cite this page
510(k) Report. “K192473: Exsomed Wrist Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K192473
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026